1. Introduction
The COMPTYCO AUA-Y710A/Y510A Optical Power Meter is a high-precision instrument designed for testing fiber optic cables and is an essential tool for Fiber To The Home (FTTH) applications. It features LED lighting for convenience in low-light conditions, wavelength memory, data storage capabilities, user self-calibration, and an automatic shutdown function to conserve battery life. This manual provides detailed instructions for the safe and effective use of your optical power meter.
2. Product Overview
The optical power meter is a compact and ergonomic device, designed for comfortable one-hand operation. It features a clear LCD display and intuitive button layout.

Figure 1: Front view of the Optical Power Meter, highlighting model ranges AUA-Y710A (-70~+10dBm) and AUA-Y510A (-50~+26dBm).

Figure 2: Detailed front view of the optical power meter, listing key features such as LED lighting, wavelength memory, 500 data stores, user self-calibration, and automatic shutdown.

Figure 3: The optical power meter display showing a list of 10 supported wavelengths: 850nm, 980nm, 1270nm, 1300nm, 1310nm, 1490nm, 1550nm, 1577nm, 1625nm, 1650nm.

Figure 4: The 2.5mm universal interface with replaceable adapters for SC, FC, ST, and optional LC connectors, ensuring wide compatibility.

Figure 5: Side and back views of the optical power meter, detailing product dimensions (180mm height, 89mm width, 42mm depth).

Figure 6: Close-up of the control panel, explaining button functions: Power switch/backlight, LED lighting, dB/W switchover, Operating wavelength switching, REF key (+0.1dB), dB key (-0.1dB), Save Data, and user self-service calibration method.
3. Specifications

Figure 7: Technical specifications of the optical power meter.
| Feature | Specification |
|---|---|
| Model Numbers | AUA-Y710A / AUA-Y510A |
| Power Measurement Range (AUA-Y710A) | -70 ~ +10dBm |
| Power Measurement Range (AUA-Y510A) | -50 ~ +26dBm |
| Probe Type | InGaAs |
| Wavelength Range | 850 ~ 1650nm |
| Standard Wavelengths (nm) | 850, 980, 1270, 1300, 1310, 1490, 1550, 1577, 1625, 1650 |
| Display Resolution (Linear) | 0.1 |
| Display Resolution (Logarithmic) | 0.01dBm |
| Test Accuracy | ±0.2dB |
| Automatic Shutdown Time | Approx. 10 minutes (in standby) |
| Dimensions (L x W x H) | 180mm x 89mm x 42mm |
| Weight | 170g |
| Power Supply | 2 x No. 5 Dry Batteries (non-rechargeable) |
| Wireless Function | No |
| High-concerned chemical | None |
4. Setup
4.1 Battery Installation
- Locate the battery compartment cover on the back of the device.
- Slide or unclip the cover to open it.
- Insert two (2) No. 5 dry batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
Note: This device uses non-rechargeable dry batteries. Do not attempt to recharge them.

Figure 8: Back view of the optical power meter showing the battery compartment for two No. 5 dry batteries (non-rechargeable).
4.2 Adapter Installation
The optical power meter features a 2.5mm universal interface. Various fiber optic connector adapters (SC, FC, ST, and optional LC) can be attached to this interface for compatibility with different fiber types.
- Select the appropriate adapter for your fiber optic connector type (e.g., SC, FC, ST, LC).
- Carefully screw or push the adapter onto the 2.5mm universal interface at the top of the device until it is secure.
- Ensure the adapter is firmly seated to prevent inaccurate readings.
5. Operating Instructions
5.1 Power On/Off and Backlight
- Press the Power/Backlight button (
) to turn the device on. - Press and hold the Power/Backlight button to turn the device off.
- A short press of the Power/Backlight button while the device is on will toggle the display backlight.
5.2 LED Lighting Function
- Press the LED button (
) to activate the built-in LED light, useful for working in dark environments. - Press the LED button again to turn off the LED light.
5.3 Wavelength Switching
- Press the Wavelength button (
) to cycle through the available standard wavelengths (850nm, 980nm, 1270nm, 1300nm, 1310nm, 1490nm, 1550nm, 1577nm, 1625nm, 1650nm). - Select the wavelength that matches the optical signal you are measuring.
5.4 dB/W Switchover
- Press the dB button (
) to switch between dBm (decibel-milliwatts) and mW (milliwatts) units for power measurement display.
5.5 Reference Value Setting (REF)
- To set a reference value for relative power measurements, connect a known optical power source to the meter.
- Press the REF button (
). The current power reading will be set as the 0dB reference. Subsequent measurements will be displayed as relative values (dB). - Press REF again to exit relative measurement mode.
5.6 Data Saving
- Press the SAVE button (
) to store the current measurement data. The device can store up to 500 groups of data. - Refer to the device's display for confirmation of data storage and to navigate through stored data.
5.7 User Self-Service Calibration
- In the shutdown state, simultaneously press and hold the Power/Backlight key and the Wavelength key for 2 seconds.
- This will enter the calibration function interface after booting. Follow the on-screen prompts for calibration.
6. Maintenance
6.1 Cleaning the Optical Interface
- Always ensure the optical interface (where adapters connect) is clean before use. Dust and debris can significantly affect measurement accuracy.
- Use a specialized fiber optic cleaning tool or lint-free wipes with isopropyl alcohol to gently clean the interface.
- Avoid touching the optical port directly with your fingers.
6.2 Battery Replacement
- When the battery indicator on the display shows low power, replace the batteries promptly to ensure accurate operation.
- Follow the steps in Section 4.1 for battery installation.
- Always dispose of used batteries according to local regulations.
6.3 General Care
- Store the device in a dry, cool place, away from direct sunlight and extreme temperatures.
- Avoid dropping or subjecting the device to strong impacts.
- Keep the device away from water and other liquids.
7. Troubleshooting
7.1 Inaccurate Readings
- Check Wavelength Setting: Ensure the selected wavelength on the meter matches the wavelength of the optical signal being tested.
- Clean Connectors: Dirty fiber optic connectors or the meter's optical interface are common causes of inaccurate readings. Clean all connections thoroughly.
- Battery Level: Low battery can affect performance. Replace batteries if indicated.
- Calibration: Perform user self-service calibration if you suspect the device is out of calibration.
7.2 Device Does Not Power On
- Check Batteries: Ensure batteries are correctly inserted and have sufficient charge. Replace with new batteries if necessary.
- Power Button: Ensure the power button is pressed firmly and held for the required duration to power on.
7.3 Automatic Shutdown Too Soon
- The device has an automatic shutdown feature after approximately 10 minutes of standby to save power. This is normal operation. If it shuts down during active use, check battery levels.
8. User Tips
- Always use the correct adapter for your fiber optic connector type to ensure a secure connection and accurate measurements.
- Take advantage of the LED lighting function when working in dimly lit areas to improve visibility and safety.
- Regularly clean the optical interface and fiber connectors to prevent signal loss and measurement errors.
- Utilize the data storage feature to record measurements for later analysis or reporting, especially for multiple test points.
9. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact your vendor. Keep your purchase receipt as proof of purchase.