1. Introduction
The TinySA ULTRA is a versatile handheld spectrum analyzer and signal generator designed for a wide range of RF applications. Featuring a 4-inch TFT LCD with touch functionality, it offers a measurement range from 100kHz up to 5.3GHz (in Ultra mode) and a signal generation capability up to 4.4GHz. This device is equipped with a built-in 3000mAh battery for portable use, an optional 20dB LNA, and supports PC control via USB. This manual provides essential information for the safe and effective use of your TinySA ULTRA.
Figure 1: TinySA ULTRA display showing a spectrum analysis with frequency range 100kHz-5.3GHz, RBW, LNA, Attenuator, Phase noise, DANL, PC & SD support, 4-inch display, and 3000mAh battery.
2. Package Contents
Please verify that all items listed below are included in your package:
- 1 x TinySA ULTRA Host
- 1 x USB Type-C data cable
- 2 x 30cm ALSR100 SMA cables
- 1 x SMA-SMA barrel connector
- 1 x Antenna with SMA connector
- 1 x Lanyard and touch plectrum
- 1 x 32GB MicroSD card (pre-installed in the host)
Figure 2: The TinySA ULTRA device and its included accessories: USB Type-C cable, two SMA cables, SMA-SMA barrel connector, antenna, lanyard, touch plectrum, and a 32GB MicroSD card.
3. Product Overview
The TinySA ULTRA is a compact and powerful tool for RF analysis. Key features include:
- Display: 4-inch TFT LCD (480x320) with sensitive touch functionality.
- Spectrum Analyzer: Measures frequencies from 0.1MHz to 800MHz, extendable to 6GHz in Ultra mode.
- Signal Generator: Produces sine wave output from 0.1MHz to 800MHz, or dual tone output up to 4.4GHz.
- Filters: Switchable resolution bandpass filters (200Hz to 850kHz).
- LNA: Built-in 20dB optional Low Noise Amplifier (LNA).
- Attenuator: Input step attenuator from 0dB to 31dB.
- Calibration: Built-in calibration signal generator for self-test and input calibration.
- Connectivity: USB-CDC (Type-C) for PC control, UART-TTL (2.54mm Connector).
- Storage: Built-in 32GB MicroSD card for data recording and storage.
- Battery: Rechargeable Li-polymer 3.7V 3000mAh battery for portable use (minimum 2 hours).
Figure 3: TinySA ULTRA handheld device with a stylus interacting with the 4-inch touch screen, highlighting its ESD protection and version V0.4.5.1. Icons indicate 100kHz-5.3GHz range, 4-inch screen, 3000mAh battery, signal generator function, 32GB card support, and PC control.
Figure 4: Detailed view of the TinySA ULTRA, labeling its components: On/Off button, Indicator light, Multi-functional knob, Type-C interface, SD Card interface, and 3.5mm jack. It also shows a built-in 32GB Micro SD Card.
4. Setup
4.1 Initial Charging
Before first use, fully charge the TinySA ULTRA using the provided USB Type-C cable and a compatible USB power adapter (not included). The charging indicator light will show the charging status.
4.2 MicroSD Card
The 32GB MicroSD card comes pre-installed. If you need to remove or replace it, gently push the card into the slot until it clicks, then release to eject. Ensure the device is powered off before inserting or removing the card.
4.3 Connecting Antennas and Cables
Connect the appropriate SMA cables or antenna to the RF connectors on the device. The device features SMA female connectors. Use the provided SMA-SMA barrel connector if needed for specific setups. Ensure connections are secure but do not overtighten.
Figure 5: TinySA ULTRA connected to a circuit board with SMA cables, demonstrating its use in an electronic testing environment.
4.4 Powering On/Off
Press and hold the On/Off button (refer to Figure 4) to power the device on or off. The indicator light will illuminate when the device is active.
5. Operating Instructions
5.1 Navigation
The TinySA ULTRA features a 4-inch touch screen for intuitive navigation. Additionally, a multi-functional knob (jog button) can be used to scroll through menus and select options. Tap on-screen elements or rotate/press the knob to interact with the interface.
5.2 Spectrum Analyzer Mode
In Spectrum Analyzer mode, you can measure RF signals. Adjust parameters such as:
- Frequency Range: Set the start and stop frequencies for your scan. The device supports 0.1MHz-800MHz, and up to 6GHz in Ultra mode.
- Resolution Bandwidth (RBW): Select from 200Hz to 850kHz to control the frequency resolution.
- LNA: Enable or disable the 20dB Low Noise Amplifier for improved sensitivity.
- Attenuator: Adjust the input attenuation from 0dB to 31dB to prevent signal overload. Note that LNA and attenuator cannot be used simultaneously.
5.3 Signal Generator Mode
The device can generate sine wave signals up to 800MHz or dual-tone signals up to 4.4GHz. Select the desired frequency and output level from the menu.
5.4 PC Control
Connect the TinySA ULTRA to a PC using the USB Type-C cable. The device will be recognized as a PC-controlled spectrum analyzer or signal generator, allowing for advanced control and data analysis using compatible software (software not included, typically available from the TinySA community or manufacturer's website).
5.5 Firmware Update
To activate firmware update mode, push and hold the jog button before switching on the device. Follow the specific instructions provided with the firmware update package.
6. Maintenance
6.1 Cleaning
Wipe the device with a soft, dry cloth. Do not use liquid cleaners or solvents, as they may damage the screen or internal components.
6.2 Battery Care
To prolong battery life, avoid fully discharging the device frequently. Store the device in a cool, dry place when not in use for extended periods. Recharge the battery periodically if stored for a long time.
6.3 Storage
Store the TinySA ULTRA and its accessories in a protective case to prevent physical damage and exposure to dust or moisture.
7. Troubleshooting
- Device does not power on: Ensure the battery is charged. Connect to a USB power source and try again.
- No signal detected: Check all cable connections. Ensure the correct frequency range and attenuation settings are selected. Verify the antenna is properly connected.
- Incorrect readings: Perform a calibration using the built-in calibration signal generator. Check for external interference.
- PC connection issues: Ensure the correct drivers are installed on your PC. Try a different USB port or cable.
- Touch screen unresponsive: Try restarting the device. If the issue persists, ensure the screen is clean and free of debris.
8. User Tips
- Always be mindful of the maximum input level (+10dBm) to avoid damaging the device.
- For precise measurements, allow the device to warm up for a few minutes after powering on.
- Explore online communities and forums dedicated to TinySA for advanced usage tips, software recommendations, and troubleshooting advice.
- Regularly check for firmware updates to ensure optimal performance and access to new features.
9. Specifications
| Parameter | Specification |
|---|---|
| Display size | 4” TFT LCD (480×320) |
| Max low input frequency | 800MHz, 6GHz in Ultra mode |
| Resolution filters in 1,3,10 steps | from 200Hz to 850kHz |
| Max output frequency | Sinus up to 800MHz |
| Output level | -104dBm to -16dBm |
| Ultra mode | Level calibrated up to 5.3GHz |
| Internal LNA gain | 20dB up to 4GHz |
| Displayed points per scan | max 450 |
| 0-350MHz scan time | 165ms |
| Shortest zero span time | 17ms |
| DANL at 100MHz | -153dBm/Hz (LNA Off) / -169dBm/Hz (LNA On) |
| DANL degrading in ultra mode | 10dB above 2.5GHz, 25dB above 5.3GHz |
| Phase noise at 10kHz bias | -92dBc/Hz |
| Phase noise at 100kHz bias | -110dBc/Hz |
| Input 1dB compression level | +0.5dBm (LNA Off) / -26.5dBm (LNA On) |
| IIP3 without LNA | +18dBm (at least 2MHz apart) / 0dBm (500Hz apart) |
| IIP3 with LNA | -8dBm (at least 2MHz apart) |
| Frequency stability | <1ppm ( -10℃ ~ +55℃) |
| SD card slot | micro SD card |
| Audio out | 3.5mm headphone plug |
| FW update mode activation | Push jog button before switch on |
| Maximum current consumption | 330mA |
| Maximum charging current | 1300mA |
| Battery | Li-polymer 3.7V 3000mAh |
| RF connectors | SMA female |
| Communication Interface | USB-CDC(Type-C), UART-TTL(2.54mm Connector) |
| Appearance Size | 117x72x23mm (Excluding protruding parts) |
Figure 6: Table of detailed specifications for the TinySA ULTRA, including display size, frequency ranges, filter resolution, output levels, LNA gain, scan times, DANL, phase noise, compression levels, frequency stability, and interface details.
Figure 7: Continuation of the specifications table, detailing maximum current consumption, charging current, battery type, RF connectors, communication interface, and appearance size.
10. Warranty and Support
For warranty information and technical support, please refer to the official TinySA website or contact your point of purchase. Keep your purchase receipt as proof of purchase.