KeepLiNK 6-Port Multi-Gigabit Switch User Manual

Model: KP-9000-6XH-X2

1. Introduction

The KeepLink 6-port Multi-Gigabit unmanaged Switch, KP-9000-6XH-X2, helps businesses cost effectively expand their networks with multi-gig speeds. It features four (4) 2.5G ports and two (2) 10G SFP+ ports, housed in a durable metal case. Designed for silent, fan-less operation, it supports desktop or wall mounting and offers plug-and-play functionality without requiring complex configuration. The switch is energy efficient, built to last, and rigorously tested for reliability. It also includes 802.1p traffic prioritization and jumbo frame support for seamless network integration.

This manual provides detailed instructions for the installation, operation, and maintenance of your KeepLiNK Multi-Gigabit Switch. Please read it thoroughly before using the device.

KeepLiNK Multi-Gigabit Switch, KP-9000-6XH-X2, 4x 2.5Gb RJ45 + 2x 10Gb SFP+

Figure 1: KeepLiNK Multi-Gigabit Switch (KP-9000-6XH-X2)

2. Packing List

Upon unpacking, please verify that all items listed below are included and in good condition:

  • Device (KeepLiNK 6-Port Multi-Gigabit Switch)
  • AC power cord (for built-in power supply device, if applicable)
  • Power adapter (for non built-in power devices)
  • Hanging ears, screws (for rack mounted device, if applicable)
  • User manual (this document)
  • Certificate of conformity
User-submitted image: KeepLiNK switch inside its retail box

Figure 2: Switch and accessories in packaging

3. Setup and Installation

3.1 Installation Precautions

  • Always ensure the power is off before installation.
  • The switch requires the correct power supply. Verify the power supply voltage matches the device's requirements.
  • Do not overload the power circuit to prevent operational issues.
  • To avoid electric shock, do not open the switch casing while it is in operation or attempt repairs yourself.

3.2 Network Cable Requirements

  • For 100Mbps connections: Use Cat5 or above Ethernet cable.
  • For 1000Mbps/2.5GE/5GE connections: Use Cat5e or above Ethernet cables.
  • For 10GE connections: Use Cat6a or above Ethernet cables.

3.3 Fiber Optic Cable Requirements

  • Fiber optics and connectors must be used with compatible optical modules.
  • Ensure the bending radius of the optical fiber is not less than 40mm.

3.4 Switch Installation Methods

The switch supports desktop, wall-mounted, and rack-mounted installations. Choose the method suitable for your environment.

Desktop Installation

Place the switch on a flat, stable desktop. Ensure adequate ventilation and heat dissipation space around the device. Do not place heavy objects on the switch.

Wall Mounting Installation

  1. Mark the positions for drilling on the wall, matching the wall mounting holes on the switch. Ensure a distance of 3mm ± 0.5mm between the nuts and the wall.
  2. Punch holes and insert embedded nails (if required).
  3. Align the switch's mounting holes with the screws on the wall and secure it.
User-submitted image: KeepLiNK switch with power adapter (EU plug variant)

Figure 3: Switch with EU power adapter, ready for installation

Rack Mounted Installation

  1. Attach the provided hanging ears to both ends of the device using screws.
  2. Slide the device parallel into the cabinet tray and secure it with cabinet screws.
User-submitted image: Hand plugging an Ethernet cable into the KeepLiNK switch

Figure 4: Connecting an Ethernet cable to the switch

4. Operating Instructions

4.1 Product Indicator Lights

The indicator lights provide visual feedback on the switch's status and port activity. Refer to the table below for details:

SignDefinitionStatusDescription
PWR/BPower indicator lightGreen light always onPower is connected/not connected
AI PoEAI lightGreen light always onAI PoE started/not started
SYS/NMS-S/NSystem lightGreen light on/offSystem working/system not started
100Mbps copper port Connection status indicator lightLeft light SpeedYellow light always on100M speed
Yellow light off10M speed
Right light Link/actGreen light always onPort connected
1000Mbps copper port Connection status indicator lightLeft light SpeedYellow light always on1000M speed
Yellow light off10-100M speed
Right light Link/actGreen light always onPort connected
2.5G copper port Connection status indicator lightLeft light SpeedYellow light on2.5G speed
Yellow light off or green light always on10/100/1000M speed
Right light Link/actGreen light always onPort connected or 10/100/1000M speed
10G copper port Connection status indicator lightLeft light SpeedYellow light on10G speed
Green light on5G speed
Light blinkData transmission and reception
10G downlink fiber port Connection status indicator lightLink/actYellow light always on10G speed
Green light always on1G rate
Light offPort not connected
Optical port connection status indicator lightLink/actGreen light onPort connected
Green light offPort not connected

Note: The specific indicator lights may vary slightly based on the actual product.

User-submitted image: KeepLiNK switch connected to network cables, showing active link lights

Figure 5: Active link lights on the switch

4.2 DIP Switch Settings

The DIP switches allow for configuration of specific functions. Ensure the power is off before changing DIP switch settings.

DIP Switch Definition for Non-PoE Switch

DIP switch specificationSequenceDefinition of DIP switchDescription
4 DIP Switch1ReserveReserve
2Extend250m long distance transmission (downlink port)
3Port IsolationPort isolation
4Storm ControlSuppress broadcast data

DIP Switch Definition for PoE Switch

DIP switch specificationSequenceDefinition of DIP switchDescription
4 DIP Switch1AI POEAuto detect and reboot unresponsive PoE devices for recovery
2Extend250m long distance transmission (PoE port)
3Port IsolationPort isolation
4Storm ControlSuppress broadcast data
3 DIP Switch1Extend250m long distance transmission (PoE port)
2StandardNormal mode
3Port IsolationPort isolation
2 DIP Switch1Extend250m long distance transmission (PoE port)
2AI PoE/ReserveAI PoE/Reserve

DIP Switch Definition for Management Switches

Note: This section applies to models with advanced management capabilities. The KP-9000-6XH-X2 is primarily an unmanaged switch, but some models in this series may offer these features.

DIP switch specificationSequenceDefinition of DIP switchDescription
3 DIP Switch1Well-managedWEB management
2StandardStandard mode
3Port ControlPort isolation

Note: The specific DIP switch definition shall be based on the actual product.

4.3 PoE Powered Function (for PoE Switches only)

This feature is applicable to PoE switches. Standard PoE power supply includes protocol detection, power pin sequence detection, power output, anomaly protection, and link anomaly monitoring.

  • **PoE Protocols:** Supports IEEE802.3af (15.4W), IEEE802.3at (30W), and IEEE802.3bt (90W).
  • **PoE Pin Sequence:** Standard PoE uses 1,2+/3,6-. Standard PoE++ uses 1,2,4,5+/3,6,7,8-.
  • Standard PoE switches automatically detect and provide power to standard PoE devices. Non-PoE devices will only transmit data without being powered on.
User-submitted image: Close-up of the KeepLiNK switch ports with connected cables

Figure 6: Close-up of switch ports

4.4 Management (for Network Management Products only)

This section applies only to network management products. For first-time use, please refer to the following instructions:

WEB Management

  1. Connect the device to a PC and ensure the device initialization is complete.
  2. Configure the IP address of the PC and the default IP address of the switch to be in the same network segment.
  3. Open a web browser on your PC and input "http://192.168.1.168". Press "Enter" to access the network management login interface.
  4. Enter the default username "admin" and password "admin" to log in.
User-submitted image: KeepLiNK switch with power adapter (UK plug variant)

Figure 7: Example of power adapter connection

Console Port Management

  1. Use a console port cable to connect the console port of your PC to the switch.
  2. Open terminal simulation software (e.g., PuTTY, Tera Term), establish a connection, select the serial port, and configure the communication parameters as follows:
    • Transmission rate: 115200
    • Data bit: 8
    • Check digit: None
    • Stop bit: 1
    • Flow control method: None

5. Maintenance

5.1 Equipment Installation Environment Precautions

To ensure the long-term stable operation and extend the service life of your switch, observe the following environmental guidelines:

  • **Temperature and Humidity:** Maintain the environment within the specified temperature and humidity ranges. Extreme conditions can lead to insulation material leakage, deformation, and metal corrosion.
  • **Static Electricity:** Regularly remove dust, maintain clean indoor air, ensure proper grounding of the equipment, and facilitate smooth transfer of static electricity to prevent damage from static discharge.
  • **Electromagnetic Interference:** Keep the switch away from high-frequency, high-power, and high-current equipment. Ensure the power supply system has necessary anti-grid interference measures.
  • **Lightning Protection:** For outdoor wiring, it is recommended to use signal lightning protectors. Ensure the rack, power sockets, and ground are in good contact, and wiring is reasonable to avoid internal induced lightning.

Video 1: Promotional video showcasing the features and applications of the KeepLiNK Multi-Gigabit Switch.

6. Troubleshooting

This section provides general troubleshooting tips. For more complex issues, please refer to the official support resources.

  • **No Power:** Check the power adapter connection and ensure the power outlet is functional. Verify the PWR/B indicator light is on.
  • **No Link Light:** Ensure the Ethernet cable is securely connected to both the switch port and the connected device. Check the cable for damage. Verify the Link/Act indicator light is on.
  • **Slow Connection Speed:** Check the cable type (e.g., Cat5e for 2.5G, Cat6a for 10G). Ensure connected devices support the desired speed. Verify the speed indicator lights on the switch.
  • **Network Congestion:** If experiencing network slowdowns, consider enabling "Port Isolation" or "Storm Control" via the DIP switches if your switch model supports these features and your network setup requires them.
  • **Unresponsive PoE Device (for PoE models):** If a PoE device is unresponsive, the "AI POE" function (if enabled via DIP switch) can automatically detect and reboot the device for recovery.
  • **Accessing Web Management:** If unable to access the web management interface, ensure your PC's IP address is in the same network segment as the switch's default IP (192.168.1.168).

7. Specifications

FeatureSpecification
Brand NamekeepLiNK
Model NumberKP-9000-6XH-X2
Number of Interfaces7 (4 x 2.5Gb Port + 2 x 10G SFP+)
Transmission Rate10000 Mbps
Switch Capacity60Gbps
Communication ModeFull-Duplex & Half-Duplex
VLAN SupportYes
FunctionVLAN Support
Packet forwarding rate33.48Mpps
MAC address table4K
Buffer8.1M
Forwarding delay<10us
Jumbo frameSupport 16Kbytes
Operating temperature-10℃~+55℃
Product size175*73*28 mm
Installation MethodDesktop / wallmount
Weight0.32 kg
Package Weight0.541 kg
Package Dimensions (L x W x H)22 x 15 x 7 cm
CertificationCE, FCC, RoHS
OriginMainland China

8. User Tips

Based on user experiences, here are some helpful tips for using your KeepLiNK Multi-Gigabit Switch:

  • **SFP+ Compatibility:** The switch works well with various brands of SFP+ connectors. Users have reported successful integration with SFP+ to RJ45 modules for 10Gbps connections.
  • **Plug-and-Play:** The switch is highly praised for its automatic connection and fast startup, making setup straightforward.
  • **Heat Management:** The device is designed to be fan-less and generally runs cool, even under load.
  • **Stable Performance:** Users consistently report stable connections at full advertised speeds (2.5Gbps and 10Gbps).
  • **Build Quality:** The metal casing is noted for its high quality and durability.

9. Warranty and Support

9.1 After-sales Service Commitment

  • **Within Seven Days of Sale:** If the device fails completely, you may choose repair, replacement, or return.
  • **Seven Days to One Year from Sale:** If a performance failure occurs, the device can be repaired or replaced based on the purchase invoice and proof of three guarantees.
  • **Beyond One-Year Hardware Warranty:** The cost of replacing hardware will be borne by the user. No additional costs will be added by the company.
  • **Support:** 7x24 hour after-sales support services are provided.

9.2 Circumstances Not Covered by Warranty

Failure or damage to equipment (including parts) under the following circumstances are not covered by warranty:

  • Accessories supplied by other companies (e.g., power supply, adapter) are guaranteed by their respective manufacturers.
  • The device and its parts have exceeded the warranty period.
  • Equipment failure or damage caused by unauthorized repair, alteration, or demolition by personnel not from our company.
  • Malfunctions caused by accidental or artificial causes, including improper operation, scratching, handling, moving, knocking, or incorrect voltage input.
  • Failure or damage caused by the use of non-genuine or unpublished software.
  • Failures or losses caused by natural disasters (e.g., earthquakes, fires).

9.3 Additional Resources

A detailed user manual in PDF format is available for download for further information: User Manual (PDF).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.