TENSTAR ROBOT TB6600

Contents

TENSTAR ROBOT TB6600 Stepper Motor Driver

Instruction Manual

Model: TB6600

Brand: TENSTAR ROBOT

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the TENSTAR ROBOT TB6600 Stepper Motor Driver. This upgraded version of the TB6600 driver is designed for high-performance applications, supporting up to 32 micro-steps and compatible with 2-phase and 4-phase stepper motors (4-wire, 6-wire, 8-wire) of types 42, 57, and 86. It is ideal for CNC engraving machines and other precision motion control systems.

Features

  • Wide DC supply voltage range: 9V-42V.
  • H-bridge bipolar constant phase flow driven.
  • Eight optional output current settings, with a maximum output current of 4.0A.
  • Six subdivision modes available, supporting up to 32 micro-steps.
  • High-speed optical isolation for input signals.
  • Standard common anode single pulse interface.
  • Offline hold function.
  • Semi-enclosed chassis for adaptability to various environments.
  • Energy-efficient semi-automatic current lock function.
  • Built-in temperature protection and overcurrent protection.

Specifications

Attribute Value
Model Number TB6600
Brand Name TENSTAR ROBOT
Type Voltage Regulator / Stepper Motor Driver
Supply Voltage DC 9V-42V
Max Output Current 4.0A
Micro-step Settings 1, 2/A, 2/B, 4, 8, 16, 32 (segments)
Application Computer, CNC Engraving Machine
Operating Temperature 1 (unspecified unit, typically ambient)
Dissipation Power 1 (unspecified unit)
Package Type SMD
Package Dimensions (L x W x H) 10 cm x 8 cm x 4 cm
Package Weight 0.121 kg

Setup

1. Wiring Diagram

Connect the stepper motor driver according to the appropriate wiring diagram for your control system (common anode or common cathode). Ensure all connections are secure before applying power.

Wiring diagram for TB6600 Stepper Motor Driver showing common anode and common cathode connections.
Detailed wiring diagram for common anode (active low) and common cathode (active high) connections. Note that the control system common voltage is 3.3V~24V universal, and no series resistance is required. The drive power is 9-42VDC.

Important: The control system common is universal for +3.3V to +24V. No series resistance is required for the control signals. The drive power supply must be within the 9-42VDC range.

2. Microstep and Current Settings

The driver features DIP switches (SW1-SW6) to configure micro-step resolution and output current. Refer to the image below and the tables for correct settings.

Front view of the TB6600 Stepper Motor Driver showing DIP switches and their corresponding microstep and current setting tables.
Front view of the driver with DIP switch settings for microstep and current.

Microstep Settings (SW1, SW2, SW3)

Microstep (Pulse/rev) SW1 SW2 SW3
NC ON ON ON
1 (200) ON ON OFF
2/A (400) ON OFF ON
2/B (800) ON OFF OFF
4 (1600) OFF ON ON
8 (3200) OFF ON OFF
16 (6400) OFF OFF ON
32 OFF OFF OFF

Current Settings (SW4, SW5, SW6)

Current (A) Pk Current (A) RMS SW4 SW5 SW6
0.5 0.7 ON ON ON
1.0 1.2 ON ON OFF
1.5 1.7 ON OFF ON
2.0 2.2 ON OFF OFF
2.5 2.7 OFF ON ON
2.8 2.9 OFF ON OFF
3.0 3.2 OFF OFF ON
3.5 4.0 OFF OFF OFF

Operating Instructions

  1. Power On: After completing all wiring and DIP switch settings, apply DC power within the 9V-42V range to the VCC and GND terminals.
  2. Signal Input: Provide pulse (PUL+ / PUL-), direction (DIR+ / DIR-), and enable (ENA+ / ENA-) signals from your control system. The input signals are optically isolated for protection.
  3. Motor Control: The driver uses H-bridge bipolar constant phase flow to control the stepper motor's movement based on the input signals and configured micro-step resolution.
  4. Offline Hold Function: The driver includes an offline hold function, which typically disengages the motor when no active signals are present, allowing for manual movement of the motor shaft.
  5. Current Lock: The energy-efficient semi-automatic current lock function helps reduce power consumption and heat generation when the motor is idle.

Maintenance

The TB6600 Stepper Motor Driver is designed with a semi-enclosed chassis to withstand various operating environments. It features built-in temperature and overcurrent protection, which helps prevent damage under abnormal conditions. For optimal performance and longevity:

  • Ensure adequate ventilation around the driver, especially if operating at higher currents or in enclosed spaces, to allow the heatsink to dissipate heat effectively.
  • Keep the driver free from dust, moisture, and corrosive substances.
  • Regularly check wiring connections for looseness or damage.
  • Do not exceed the specified input voltage or output current limits.

Troubleshooting

  • Motor not moving or erratic movement:
    • Verify all wiring connections against the diagram.
    • Check the power supply voltage (9V-42V DC) and ensure it's stable.
    • Confirm the control signals (Pulse, Direction, Enable) are correctly connected and active.
    • Ensure the microstep and current DIP switch settings match your motor and application requirements.
    • Check if the motor is properly connected (4-wire, 6-wire, or 8-wire configuration).
  • Driver overheating:
    • Reduce the output current setting if possible, ensuring it's still sufficient for the motor.
    • Improve ventilation around the driver.
    • Ensure the motor is not overloaded.
    • Verify the power supply voltage is not too high, causing excessive current.
  • Motor making noise but not moving:
    • Check motor phase wiring for incorrect connections.
    • Ensure the motor is not mechanically jammed.
    • Verify the pulse signal frequency is not too high for the motor to respond.

User Tips

  • Verify Specifications: Always ensure that the power supply and motor specifications (current, voltage, phase) are compatible with the TB6600 driver to prevent damage and ensure optimal performance.
  • Proper Cooling: While the driver has a heatsink, consider additional cooling (e.g., a small fan) if operating continuously at higher currents or in warm environments to maintain stability.
  • Test Settings: When first setting up, start with lower current and microstep settings and gradually increase them to find the optimal balance for your specific motor and application.

Warranty and Support

For technical support, troubleshooting assistance, or warranty inquiries, please contact TENSTAR ROBOT customer service. Keep your purchase records handy for faster service.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.