1. Introduction
The Hobbywing 12L Brushless Water Pump is a high-performance peristaltic pump designed for demanding agricultural applications, particularly for plant protection drones. Featuring a robust brushless motor, dual-channel output, and intelligent control options, this pump delivers precise and efficient fluid delivery. Its durable construction and IP66 protection ensure reliable operation in various environmental conditions.
2. Safety Information
Please read and understand all safety instructions before operating the pump. Failure to follow these instructions may result in injury, damage to the product, or property damage.
- Always disconnect power before performing any installation, maintenance, or troubleshooting.
- Ensure all electrical connections are secure and properly insulated to prevent short circuits.
- Operate the pump within its specified voltage range (14-18S LiPo, 44-81V).
- Do not operate the pump with flammable liquids or in explosive atmospheres.
- Wear appropriate personal protective equipment (PPE) when handling chemicals or performing maintenance.
- Keep the pump away from children and unauthorized personnel.
- Ensure proper ventilation during operation to prevent overheating.
3. Product Overview
The Hobbywing 12L pump is engineered for precision and reliability. Its compact design integrates a brushless motor, a reduction module, and a replaceable pump head module, facilitating easy maintenance and long-term use. The pump supports both CAN and PWM communication methods for flexible control and features intelligent protection mechanisms.
3.1 Components and Features
- Brushless Motor: Provides efficient and powerful operation.
- Peristaltic Design: Ensures accurate and consistent fluid delivery, suitable for various liquids.
- Dual-Channel Output: Offers two independent channels for flexible application.
- Modular Design: Power, reduction, and pump head modules are easily separable for maintenance.
- CAN+PWM Control: Supports both CAN data signals and PWM analog signals for robust, anti-interference control, enabling functions like upgrades and parameter adjustments.
- Intelligent Protection: Includes protection against signal loss, motor stall, overcurrent, and overtemperature to prevent damage.
- IP66 Protection: Provides high resistance against dust and water ingress.
- Real-time Data Transmission: Capable of transmitting data such as speed, voltage, current, and temperature for real-time monitoring.
3.2 Visual Reference







4. Specifications
| Feature | Specification |
|---|---|
| Voltage | 14-18S LiPo (44-81V) |
| Rated Power | 150W |
| Maximum Open Flow | 12 L/min (2*6L) |
| Minimum Open Flow | 0.6 L/min |
| Channels | 2 channels |
| Protection Level | IP66 |
| Weight | 778g |
| Size (L*W*H) | 151*75*124mm |
| Inlet Water Pipe Inner Diameter | 8mm |
| Outlet Pipe Inner Diameter | 8mm |
| Fixed PWM Throttle Stroke | 1050-1950us |
| PWM Level | 3.3V/5V |
| Frequency | 50-500Hz |
| Communication Method | CAN |
| Certification | CE |
| DIY Supplies Category | Electrical |
| Origin | Mainland China (Guangdong) |
5. Setup
5.1 Mounting the Pump
- Select a secure and stable location on your agricultural drone or application platform.
- Ensure the mounting surface is flat and capable of supporting the pump's weight and operational vibrations.
- Use appropriate fasteners (not included) to firmly attach the pump to the chosen location. Avoid over-tightening to prevent damage to the pump casing.
5.2 Hose Connections
- Connect the inlet hose to the designated inlet port (8mm inner diameter). Ensure the hose is free from kinks and obstructions.
- Connect the outlet hoses to the two designated outlet ports (8mm inner diameter).
- Secure all hose connections with clamps to prevent leaks during operation.
5.3 Electrical Wiring
The pump requires a 14-18S LiPo battery (44-81V) for power and supports both CAN and PWM for control. Refer to your drone's flight controller or control system manual for specific wiring diagrams.
- Power Connection: Connect the main power leads of the pump to your 14-18S LiPo battery or power distribution board, ensuring correct polarity.
- Control Signal Connection (CAN): If using CAN communication, connect the CAN H and CAN L wires from the pump to the corresponding CAN bus on your flight controller.
- Control Signal Connection (PWM): If using PWM control, connect the PWM signal wire to the appropriate PWM output on your flight controller. Ensure the PWM level is compatible (3.3V/5V) and the throttle stroke is configured within 1050-1950us.
- Ground Connection: Ensure a common ground connection between the pump and the control system.
6. Operating Instructions
6.1 Pre-Operation Check
- Verify all hose connections are secure and free of leaks.
- Confirm all electrical connections are tight and correct.
- Ensure the fluid reservoir contains sufficient liquid for the operation.
6.2 Powering On
Connect the battery to the pump's power input. The pump may perform a brief self-test upon power-up.
6.3 Control and Flow Adjustment
- CAN Control: Utilize your flight controller's software interface to send commands via the CAN bus. This allows for precise digital control of flow rate, monitoring of pump status, and advanced functions.
- PWM Control: Adjust the PWM signal from your flight controller to control the pump's speed and flow rate. The pump responds to a fixed PWM throttle stroke of 1050-1950us.
- Monitor the actual flow rate to ensure it meets your application requirements. The pump supports a maximum open flow of 12 L/min and a minimum of 0.6 L/min.
6.4 Powering Off
Disconnect the battery from the pump's power input after operation.
7. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your Hobbywing 12L pump.
7.1 Routine Checks
- Inspect hoses for wear, cracks, or blockages before each use.
- Check electrical connections for corrosion or looseness.
- Clean the exterior of the pump to prevent accumulation of dirt and debris.
7.2 Pump Head Module Replacement
The peristaltic pump head module is designed for easy replacement, which is crucial for maintaining consistent flow and pressure over time.
- Disconnect all power to the pump.
- Carefully detach the pump head module from the reduction module (refer to Figure 5 for visual guidance on modular design).
- Install a new, genuine Hobbywing pump head module, ensuring it is correctly seated and secured.
- Reconnect power and test the pump.
7.3 Storage
When not in use for extended periods, clean the pump thoroughly, drain any remaining liquid, and store it in a dry, cool place away from direct sunlight.
8. Troubleshooting
The Hobbywing 12L pump features intelligent protection to mitigate common issues. If you encounter problems, refer to the following table:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; incorrect wiring; signal loss; motor stall protection activated. | Check power connections and battery voltage. Verify control signal (CAN/PWM) is present. Inspect for obstructions causing motor stall. |
| Weak or no fluid flow | Hose blockage; air in the system; worn pump head; incorrect flow setting. | Check hoses for kinks or blockages. Prime the pump if necessary. Inspect and replace pump head if worn. Adjust flow rate via control system. |
| Unusual noise during operation | Air in the system; foreign object in pump head; loose mounting. | Bleed air from the system. Disconnect power and inspect pump head for foreign objects. Ensure pump is securely mounted. |
| Pump stops unexpectedly | Overcurrent/Overtemperature protection activated; power interruption; signal loss. | Check for excessive load or high ambient temperature. Verify stable power supply. Check control signal integrity. |
If the problem persists after attempting these solutions, please contact customer support.
9. User Tips
No specific user tips were available from reviews or Q&A for this product at the time of manual creation.
- For optimal performance in agricultural spraying, ensure the fluid being pumped is free of large particulates that could clog the pump or nozzles.
- Regularly check the condition of the peristaltic tubing within the pump head, as this is a wear item and affects flow accuracy.
- Utilize the real-time data transmission capabilities (Figure 7) to monitor pump health and performance during critical operations.
10. Warranty & Support
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.