PowMr POW-SunSmart 12KL3

Contents

PowMr POW-SunSmart 12KL3 Three-Phase Solar Hybrid Inverter Instruction Manual

Model: POW-SunSmart 12KL3 | Brand: PowMr

1. Introduction

The PowMr POW-SunSmart L3 series solar energy storage inverter is an advanced all-in-one solution integrating solar energy storage, utility charging, and AC sine wave output. Designed with DSP control, it offers high response speed, reliability, and industrial-standard performance through sophisticated control algorithms. This manual provides essential information for the safe and efficient operation of your POW-SunSmart 12KL3 inverter.

PowMr POW-SunSmart 12KL3 Hybrid Solar Inverter
Figure 1: PowMr POW-SunSmart 12KL3 Hybrid Solar Inverter

2. Package Contents

Upon opening the package, please verify that all items listed below are present and in good condition:

  • POW-SunSmart 12KL3 Inverter Unit
  • User Manual
  • Set of Installation Accessories (e.g., mounting hardware, connectors)
  • Parallel Communication Cable
  • Inspection Report
Video 1: Unboxing and Overview of the PowMr POW-SunSmart Inverter, showing package contents and key features.

3. Specifications

General Specifications

  • Brand Name: PowMr
  • Model Number: POW-SunSmart Series (12KL3)
  • Output Power: 1 - 200 KW
  • Weight: 29.5 Kg
  • Output Frequency: 50/60Hz
  • Is Smart Device: Yes
  • Origin: Mainland China
  • Certification: CE
  • High-concerned chemical: None
  • is_customized: Yes

Detailed Product Specification (POW-SunSmart 12KL3)

CategoryParameterValue (12KL3)
INVERTER OUTPUT
Rated Output Power12000W
Max. Peak Power24000W
Rated Output Voltage230/400Vac (three-phase)
Capacity of Motor Load6HP
Rated Frequency50/60Hz
Output Waveformpure sine wave
Switching Time10ms(typical)
Overload ProtectionAfter triggering the overload protection, the inverter will resume output after 3 minutes. 5 consecutive overloads will shut down the output until the inverter is restarted.(102%<load<110%) ±10%: error, output shut down after 5 minutes.(110%<load<125%) ±10%: error, output shut down after 10s.(>125% load ±10%): error, output shut down after 5s.
BATTERY
Battery TypesLi-ion / Lead-Acid / User Defined
Rated Battery Voltage48Vdc
Voltage Range40-60Vdc
Max. PV Charging Current260A
Max. Utility / Generator Charging Current120A
PV INPUT
No. of MPPT2
Max. Input Power9000W/9000W
Max. Input Current22/22A
Max. Open-circuit Voltage800Vdc/800Vdc
MPPT Operating Voltage Range200-650Vdc/200-650Vdc
UTILITY / GENERATOR INPUT
Input Voltage Rangephase voltage 170~280V, line voltage 305~485V
Input Frequency Range50Hz / 60Hz
Bypass Overload Phase Current35A
EFFICIENCY
MPPT Tracking Efficiency99.9%
Max. Battery Inverter Efficiency≥92%
European Efficiency97.5%
COMMUNICATION
Internal InterfaceRS485 / CAN / USB / Dry contact
External Module (optional)Wi-Fi / GPRS
GENERAL
Protection DegreeIP20, indoor only
Ambient Temp-10~55℃, >45℃ derated
Noise<60dB
Cooling MethodFan cooling
CERTIFICATION
SafetyIEC62109-1, IEC62109-2
EMCEN61000-6-1, EN61000-6-3, FCC 15 class B
RoHSYes

Physical Dimensions

  • Length: 57 cm
  • Width: 25 cm
  • Height: 79 cm
  • Weight: 30.0 Kg

4. Setup and Installation

The PowMr POW-SunSmart 12KL3 inverter is designed for indoor use only (IP20 protection degree). Ensure the installation location is well-ventilated and within the specified ambient temperature range of -10°C to 55°C (derated above 45°C).

4.1 Parallel Operation

This inverter supports parallel operation of up to 6 units, allowing for a total output power expansion limit of 72KW. Use the provided parallel communication cable for multi-unit setups.

Inverter parallel connection capability
Figure 2: The inverter supports parallel connection of up to 6 units for increased power output.

4.2 Battery Connection

The inverter is compatible with 48Vdc Li-ion and Lead-Acid batteries. It also supports battery-less operation, where the inverter can power loads directly from the PV array or AC grid. The maximum PV charging current is 260A, and the maximum utility/generator charging current is 120A.

For Li-ion batteries, the inverter features a dual activation function: either mains power or photovoltaic power supply access can trigger the activation of a dormant Li-ion battery.

Battery compatibility and battery-less operation
Figure 3: Inverter compatibility with 48V Lead-Acid and Lithium batteries, and battery-less operation.

4.3 PV Input Connection

The inverter features dual MPPT inputs, each capable of handling up to 22A input current and an open-circuit voltage of up to 800Vdc. The MPPT operating voltage range is 200-650Vdc.

Detailed wiring diagram for solar hybrid inverter
Figure 4: Detailed wiring diagram showing connections for Generator, Main Power, Solar Panels, Battery, and AC Output.

4.4 AC Output Connection

The inverter provides a three-phase pure sine wave output at 230/400Vac. The phase voltage can be adjusted within the range of 200, 208, 220, 230, 240Vac. The maximum output current is 19.2A.

Three-phase AC output diagram
Figure 5: Diagram illustrating the three-phase AC output (L1, L2, L3, N) with voltage measurements.

5. Operating Modes

The PowMr POW-SunSmart 12KL3 offers flexible operating modes to optimize energy usage:

5.1 Charging Modes (4 Available)

  • Solar Only: Charges batteries exclusively from solar power.
  • Mains Priority: Prioritizes utility power for charging, using solar as a secondary source.
  • Solar Priority: Prioritizes solar power for charging, using utility as a secondary source.
  • Mixed Mains and PV Charging: Utilizes both utility and PV power for charging.

5.2 Output Modes (2 Available)

  • Utility Bypass: Loads are powered directly by the utility grid.
  • Inverter Output: Loads are powered by the inverter, drawing from solar or battery.

The inverter also features an Uninterrupted Power Supply (UPS) function, ensuring continuous power during grid outages.

Diagram of 4 output modes for solar hybrid inverter
Figure 6: Illustration of the four primary output modes: Solar First, Mains First, Inverter First, and Hybrid Output/Grid Connection.

5.3 Energy-Saving Mode and Time-Slot Function

An energy-saving mode reduces no-load energy losses. The time-slot charging and discharging function allows users to leverage peak and valley electricity tariffs, storing excess solar energy during the day for use during evening peak hours, thereby reducing electricity costs. If the battery discharge time is set to zero, the inverter can function as a UPS power supply.

Peak-Valley Electricity Tariff diagram
Figure 7: Diagram illustrating peak-valley electricity tariffs and how the inverter manages charging and discharging based on time slots.

6. LCD Display and Controls

The inverter features an LCD HD display screen with a dynamic flow diagram design, making it easy to understand system data and operation status. The control buttons allow for navigation and setting adjustments.

LCD HD Display Screen and control buttons
Figure 8: LCD HD Display Screen showing real-time monitoring of photovoltaic system operating data and control buttons for settings.

6.1 Control Buttons

  • Enter/Exit Settings: Used to access and exit the settings menu.
  • Option Increase: Navigates up or increases a value in settings.
  • Option Decrease: Navigates down or decreases a value in settings.
  • OK/Enter Options: Confirms selection or enters a submenu.

6.2 Display Indicators

  • Battery Capacity: Shows the current charge level of the battery.
  • Load Percentage: Indicates the current load on the inverter.
  • Utility: Shows status of the grid connection.
  • Generator: Shows status of generator connection.
  • Solar Power: Displays current solar power generation.
  • Home Appliances: Indicates power supply to home appliances.
  • Normal State: System is operating normally.
  • Alarm/Fault State: Indicates an alarm or fault condition.

7. Protection Features

The PowMr POW-SunSmart 12KL3 inverter incorporates comprehensive 360° protection mechanisms to ensure safe and reliable operation:

  • Short Circuit Protection
  • Over Current Protection
  • Over Voltage Protection
  • Under Voltage Protection
  • Over-Load Protection
  • Backfill Protection
  • Over-Temperature Protection
  • Over Charge Protection
360 degree protection features of the inverter
Figure 9: Visual representation of the inverter's 360° protection features.

8. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.

  • Cleaning: Keep the inverter's ventilation openings clear of dust and debris. Use a soft, dry cloth for cleaning the exterior. Do not use liquid cleaners.
  • Connections: Periodically check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
  • Environment: Ensure the operating environment remains within the specified temperature and humidity ranges. The inverter is IP20 rated, meaning it is for indoor use only and not protected against water.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your inverter has the latest features and bug fixes.

9. Troubleshooting

This section covers common issues and basic troubleshooting steps. For complex problems, contact technical support.

9.1 Common Issues

  • No Power Output:
    • Check AC input breaker (ON/OFF switch on the side of the unit).
    • Verify battery connections and voltage.
    • Ensure PV input is sufficient and connections are secure.
    • Check for any fault codes on the LCD display.
  • Overload Error:
    • Reduce the connected load.
    • The inverter will attempt to restart after a delay (see Overload Protection in Specifications).
  • Battery Not Charging:
    • Check PV input voltage and current.
    • Verify utility/generator input if using those charging modes.
    • Ensure battery type settings are correct on the inverter.
  • Communication Issues (CAN, USB, RS485):
    • Check cable connections.
    • Ensure external modules (Wi-Fi/GPRS) are correctly installed and configured.

Refer to the LCD display for specific error codes and consult the full user manual (if available as a PDF) for detailed troubleshooting guides.

10. User Tips

  • Battery Protocol: When connecting external battery storage systems, ensure compatibility with the inverter's battery protocols. For example, some users have inquired about compatibility with Pylontech 51300/48300 low voltage 51V batteries. Always verify the battery's communication protocol (e.g., CAN, RS485) and voltage requirements with the inverter's specifications.
  • Optimal Performance: To maximize solar energy utilization, consider configuring the inverter to "Solar Priority" charging mode. Utilize the time-slot charging/discharging function to take advantage of off-peak electricity rates.
  • Monitoring: Regularly check the LCD display for system status and any alerts. If an external Wi-Fi/GPRS module is used, leverage remote monitoring capabilities for convenience.

11. Warranty and Support

For warranty information, technical support, or service requests, please refer to the warranty card included in your package or contact PowMr customer service directly. Ensure you have your product model number (POW-SunSmart 12KL3) and serial number ready when contacting support.

The product is certified with CE and RoHS, ensuring compliance with relevant safety and environmental standards.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.