1. Introduction

This manual provides essential information for the safe and efficient operation of your SUSWE SU900 series High Power Frequency Inverter. The SU900 series is a vector control Variable Frequency Drive (VFD) designed for precise motor speed control in various industrial applications. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper usage and prevent damage or injury.

SUSWE VFD Vector Control Inverters
Overview of SUSWE VFD Vector Control Inverters (SU900 series)

2. Safety Information

WARNING: Improper installation or operation can lead to serious injury or death. Only qualified personnel should install, operate, and maintain this equipment.

  • Always disconnect power before performing any wiring or maintenance.
  • Ensure proper grounding of the inverter and motor.
  • Do not touch electrical components when power is applied.
  • Verify input voltage matches the inverter's specifications.
  • Install the inverter in a well-ventilated area, free from moisture, dust, and corrosive gases.
  • Observe all local and national electrical codes.

3. Specifications

The SUSWE SU900 series frequency inverters are general-purpose devices suitable for a wide range of motor control applications.

3.1 General Product Information

ParameterValue
NameGeneral purpose inverter
Input Voltage220V / 380V (depending on model)
Input Frequency50/60HZ
Power Specifications0.75 - 45KW
Rated Current1.5 - 320A
Output Frequency50-400HZ
Protection LevelIP20
Cooling ModeSelf-cooling fan
Temperature Range-20 ~ +60°C
Motor UsageSuitable for fans and pumps
Scope of UseWoodworking machinery, food machinery, textile machinery, plastic machinery, CNC machine printing machinery, automation, and other motor control applications.
Product Protection6 great protections
CertificationCE, FCC, RoHS
General Product Information and Specifications
General Product Information and Specifications

3.2 Model-Specific Parameters (Example: SU900-7R5G3)

ParameterValue
ModelSU900-7R5G3
Rated Current17A
Adapted Motor7.5KW 10Hp
Input VoltageThree phase 380V
Output VoltageThree phase 380V
External Dimensions202 x 102 x 161.68 MM
Gross Weight2.1 Kg
Example Product Parameters for SU900-7R5G3
Example Product Parameters for SU900-7R5G3

3.3 800/900 Series Index

Refer to the table below for detailed power and current specifications across the SU800 and SU900 series.

800/900 Frequency Converter Series Index
Detailed Specifications for SU800/SU900 Series (Single and Three Phase)

4. Setup & Installation

4.1 Physical Dimensions

The SU900 series inverters come in various sizes depending on their power rating. Below are diagrams for different external unit sizes (C1, C2, C3, C4, C5) and the models they correspond to.

C1 External Unit Dimensions
C1 External Unit Dimensions (Suitable for SU800-0R75G2 to SU800-2R2G2, SU800-0R75G3 to SU800-2R2G3)
C2 External Unit Dimensions
C2 External Unit Dimensions (Suitable for SU800-5R5G2 to SU800-7R5G2, SU800-4R0G3 to SU900-7R5G3)
C3 External Unit Dimensions
C3 External Unit Dimensions (Suitable for SU900-7R5G3, SU900-11R0G3, SU900-15R0G3)
C4 External Unit Dimensions
C4 External Unit Dimensions (Suitable for SU900-18R5G3, SU900-22R0G3)
C5 External Unit Dimensions
C5 External Unit Dimensions (Suitable for SU900-18R5G3, SU900-22R0G3)

4.2 Terminal Instructions

The main circuit terminals are used for power input, braking resistance, and motor output connections.

TerminalsNameInstruction
R, S, T / L, NPower supply input terminalsConnection point of three-phase 380V or single-phase 220VAC power supply
P+, PBBrake electric resistance connection terminalsConnect brake electric resistance
U, V, WFrequency converter output terminalsConnect three-phase motor
Grounding terminalsGrounding terminals
Frequency Converter Main Circuit Terminal Instructions and Control Circuit Wiring Diagram
Frequency Converter Main Circuit Terminal Instructions and Control Circuit Wiring Diagram (Fig 2-2)

4.3 Wiring Diagrams

Ensure correct wiring according to your specific inverter model and power supply type. Always connect the ground wire.

SU900 7.5KW-22KW G1 Type Wiring Diagram
SU900 7.5KW-22KW G1 Type Wiring Diagram (Three-phase input)
G3 Type Wiring Diagram
G3 Type Wiring Diagram (Three-phase input)
SU800 4KW-7.5KW G1 Type Wiring Diagram
SU800 4KW-7.5KW G1 Type Wiring Diagram (Three-phase input)
G2 Type Wiring Diagram
G2 Type Wiring Diagram (Three-phase input)
SU800 0.75KW-2.2KW G1 Type Wiring Diagram
SU800 0.75KW-2.2KW G1 Type Wiring Diagram (Single-phase input)

5. Operating Instructions

5.1 Control Panel Overview

The inverter features a user-friendly control panel for monitoring and adjusting parameters. The panel can also be detached for remote operation using an external extension network cable.

SUSWE VFD Control Panel Layout and Functions
Man-machine interactive key panel with labeled functions
Detachable Smart Panel with Network Cable Connection
Detachable smart panel for flexible working conditions

5.2 Key Functions

  • Knob: Adjusts speed or parameter values.
  • Display Screen: Shows frequency, current, voltage, and other operating data.
  • Run Key (RUN): Starts the motor.
  • Stop/Reset Key (STOP/RESET): Stops the motor or resets errors.
  • Confirm Key (ENTER): Confirms parameter settings.
  • Programming Key (PROG): Enters/exits programming mode.
  • Increment Key (▲): Increases parameter values or navigates up.
  • Decrement Key (▼): Decreases parameter values or navigates down.
  • Shift Key (>): Shifts cursor position during parameter entry.
  • Multi-function Keys (MFK): Customizable functions, refer to the full product manual for specific programming.

5.3 Basic Operation Sequence

  1. Power On: Ensure all wiring is correct and secure before applying power.
  2. Parameter Setting: Use the PROG key to enter programming mode. Navigate through parameters using ▲/▼, adjust values with the knob, and confirm with ENTER.
  3. Start Motor: Press the RUN key to start the motor.
  4. Adjust Speed: Use the knob to adjust the motor speed during operation.
  5. Stop Motor: Press the STOP/RESET key to stop the motor.

6. Maintenance

Regular maintenance ensures the longevity and reliable operation of your inverter.

  • Cleaning: Keep the inverter clean and free from dust. Use a soft, dry cloth. Do not use liquid cleaners.
  • Ventilation: Ensure adequate airflow around the inverter. Regularly check that the cooling fan is free from obstructions and operating correctly. The DC fan provides efficient heat dissipation.
  • Connections: Periodically check all terminal connections for tightness. Loose connections can cause overheating and malfunction.
  • Environment: Maintain the operating environment within specified temperature and humidity ranges. The inverter features a three anti-paint process for improved stability in harsh environments.
DC Fan for Efficient Heat Dissipation
DC fan for quick and efficient heat dissipation
Three Anti-Paint Process for Circuit Board
Internal circuit board with three anti-paint process for enhanced durability

7. Troubleshooting

If the inverter is not functioning as expected, consider the following basic troubleshooting steps:

  • No Power: Check input power connections and circuit breaker.
  • Motor Not Running: Verify wiring to the motor, check control panel settings, and ensure the RUN command is active.
  • Overload Error: Check motor load, ensure the motor is not jammed, and verify inverter capacity matches motor requirements.
  • Overvoltage/Undervoltage Error: Check input power supply stability.
  • Overheat Error: Ensure proper ventilation, clean cooling fins, and check fan operation.

For detailed error codes and advanced troubleshooting, please consult the comprehensive product manual or contact technical support.

8. User Tips

  • Initial Setup: Double-check all wiring before applying power. Incorrect wiring is a common cause of initial setup issues.
  • Parameter Adjustment: When adjusting parameters, make small changes and observe the motor's response. Refer to the detailed manual for parameter descriptions.
  • Environmental Considerations: While the inverter is designed for industrial environments, protecting it from excessive moisture, dust, and extreme temperatures will extend its lifespan.
  • Remote Panel: Utilize the detachable panel for convenience in installations where the main unit is not easily accessible.

9. Warranty & Support

For warranty information, technical support, or service inquiries, please contact your vendor or the manufacturer directly. Ensure you have your product model number (e.g., SU900-7R5G3) and purchase details available when seeking support.

Related Documents - SU900

Preview SUSWE SU-300 系列矢量变频器操作说明书
SUSWE SU-300系列矢量变频器操作说明书。提供详细技术规格、安全指南、接线图、操作方法、通讯协议及故障排除。适用于工业自动化、水泵、风机等应用。
Preview SUSWE SU-600 Series Vector Frequency Inverter Operating Specification Manual
Comprehensive operating specification manual for the SUSWE SU-600 series vector frequency inverter, detailing technical specifications, installation, wiring, communication protocols, parameter settings, and troubleshooting.
Preview SUSWE Miniature AC Motor Driver Inverter User Manual
Comprehensive user manual for SUSWE miniature AC motor drivers, detailing installation, wiring, key functions, parameter settings, and fault codes for optimal operation and maintenance.
Preview SUSWE Inverter User Manual - Installation, Operation, and Parameters
Comprehensive user manual for the SUSWE Inverter, covering overview, installation, wiring, key functions, detailed parameter descriptions, and fault code troubleshooting. Suitable for Miniature AC Motor Driver applications.
Preview SUSWE Miniature AC Motor Driver Inverter User Manual
Comprehensive user manual for the SUSWE Miniature AC motor driver inverter, covering installation, wiring, key descriptions, parameter settings, and fault codes. Includes detailed specifications and operational guidance.
Preview SUSWE Electric Inverter User Manual - Installation, Operation, and Parameter Guide
Comprehensive user manual for the SUSWE Electric 1-single-in three-out inverter, covering installation, wiring, key functions, parameter settings, fault codes, and ModBus communication. Includes detailed parameter lists and troubleshooting information.