This manual provides essential information for the safe and efficient operation of your ZJIVNV 350W UPS Switching Power Supply. Please read it thoroughly before installation and use.
Product Features:
- International common AC input voltage range, switchable.
- Compact size, light weight, high efficiency, and a height of only 30mm.
- Protection characteristics: short circuit, overload, over temperature.
- Battery low voltage protection.
- Power on, charging, and mains display via light-emitting diodes (LEDs).
- 100% full load burn-in tested.
- AC to battery power supply with no switching time, ensuring continuous operation.
- Battery charging terminal includes a fuse; reverse battery connection will not damage the switching power supply.
External Indicator Description (CN1):
- GREEN: DC output indicator.
- RED: AC input indicator.
- YELLOW: Battery charging indicator.


2. Setup and Installation
Before Power On:
- Wiring Check: Ensure the input and output lines are correctly connected. This includes the live wire (L), neutral wire (N), and earth wire for AC input, and positive pole (+V) and negative pole (-V) for DC output.
- Wire Cross-Section: Verify that the cross-section of the input electric wire is sufficient. The reduction in AC voltage should not exceed 5%, and DC voltage should not exceed 0.5%.
- Connections: Confirm that all screw connections and switching device (board) contacts are secure. Check the insulation resistance and withstand voltage between the shell and input/output meet requirements.
- Grounding: The earth wire must be firmly grounded to ensure safety and reduce interference. The section surface of the grounded copper wire should exceed 0.75mm².
- Input Voltage Selection: Before connecting to AC power, ensure the 115V/230V switch is set correctly according to your local mains voltage. Incorrect setting can damage the power supply.

Wiring Layout:
Refer to the diagram below for proper wiring connections. Pay close attention to the polarity for battery connections and the correct terminals for AC input and DC output.

Battery Charging Terminal:
The battery charging terminal is equipped with a fuse. This fuse protects the switching power supply from damage in case of reverse battery connection. Always ensure the fuse is correctly installed.
3. Operating Instructions
Output Characteristics:
This multi-general switching power supply features both main and secondary outputs. The main output generally has superior characteristics compared to the secondary output. Typically, the main output is the one with a larger rated output current or that handles stable load power. If only secondary output is used, a dummy load equivalent to 30% of the rated power output must be added (this does not apply to custom-made or dedicated power supplies).
UPS Function:
The power supply includes an automatic switching UPS function with no switching time. This means that in the event of a mains power failure, the system will seamlessly switch to battery power without interruption, ensuring continuous operation of connected devices. This feature eliminates the need for manual intervention during power outages.

4. Maintenance and Care
Environmental Conditions:
To ensure optimal performance and extend the service life of your power supply, avoid abnormal environmental conditions such as:
- High temperature or humidity (ensure absolutely dry conditions).
- Excessive dust.
- Exposure to acid-base pollution.
The switching power supply can operate at full load within a specific temperature range. If the ambient temperature exceeds the upper control limit, the output power should be reduced according to the power-output curve. For example, if the normal operating temperature is -10°C to 40°C, and the environment temperature reaches 70°C, the output power should not exceed 50% of its rated value. If the environment temperature is below -10°C, the switching power supply may not start or operate normally.
Cooling and Airflow:
Ensure the power supply operates in an unblocked air environment to allow for proper heat dissipation. The unit is equipped with a built-in fan for cooling. Regular cleaning of dust from the fan and ventilation openings is recommended to maintain efficient cooling and prevent overheating.

Physical Installation:
When installing, do not use screws that are too long, as they may contact the circuit board and components, potentially causing damage or danger. Remove any outside plastic packing before installation.
5. Troubleshooting
- Power Supply Not Starting/Abnormal Output: If the ambient temperature is below -10°C, the power supply may not start or output normally. Ensure the operating environment is within the specified temperature range.
- Frequent Input Voltage Fluctuations: If the supplying voltage fluctuates dramatically (over-voltage/low-voltage), consider installing a power stabilizer or an over/under voltage protector before connecting the equipment.
- Impact on Life: Frequently switching the input voltage or experiencing exceptions can negatively affect the lifespan of the power supply.
- Large Electrical Equipment: When supplying power to large electrical equipment, consider installing an AC filter to prevent interference.
- Battery Reverse Connection: The battery charging terminal is designed with a fuse to prevent damage to the switching power supply in case of accidental reverse battery connection. If the unit is not functioning after a reverse connection, check and replace the fuse.
6. Specifications
| Attribute | Specification (PSC-350-12) | Specification (PSC-350-24) |
|---|---|---|
| Model | PSC-350-12 | PSC-350-24 |
| DC Output Voltage | CH1:13.8V, CH2:13.8V | CH1:27.6V, CH2:27.6V |
| Output Voltage Tolerance | ±1% | ±1% |
| Rated Output Current | 20A (load), 5A (charge) | 10A (load), 2.5A (charge) |
| Output Current Range | 0~25A | 0~12.5A |
| Output Power | 345W | 350W |
| Ripple and Noise | 180mVp-p | 200mVp-p |
| DC Voltage Adjustable Range | CH1:11.3~14.9V | CH1:21.3~29.8V |
| Start-up, rise and hold times | 600ms, 50ms, 80ms 230VAC / 1200ms, 50ms, 16ms 115VAC | 600ms, 50ms, 80ms 230VAC / 1200ms, 50ms, 16ms 115VAC |
| Input Voltage Range | 90~264VAC or 135~370VDC | 90~264VAC or 135~370VDC |
| AC Input Current | 6.5A 115VAC, 3.5A 230VAC | 6.5A 115VAC, 3.5A 230VAC |
| Efficiency | 87% | 89% |
| Inrush Current | Cold start current 45A/115VAC, 55A/230VAC | Cold start current 45A/115VAC, 55A/230VAC |
| Leakage Current | <1mA/240VAC | <1mA/240VAC |
| Protective properties | Overload protection: Activated at 105%~115% of rated output power. Protection Mode: AC Charging Mode: Spacing Mode, automatic recovery after removal of abnormal load conditions. | |
| Battery Low Voltage Protection | 9.5~10.5V | 19~20.5V |
| Protection mode | Cut-off output | |
| UPS function introduction | Long-term on-line float charging of the battery, high charging efficiency; the battery fullness can be as high as 98% or more. Self-stopping when full, preventing overcharging and prolonging the life of the battery. Automatic switching between mains battery, no switching time, no need to be manned. Cold start function, in the absence of the state of the utility, you can directly use the battery to start the UPS, to meet the emergency needs of users. | |
| Operating temperature, humidity | -20°C~60°C; 20%~90%RH non-condensing | |
| Storage temperature, humidity | -20°C~85°C; 10%~95%RH non-condensing | |
| Seismic defenses | 10~500Hz, 2G 10min./1cycle, 60min. each axis | |
| Pressure resistance | Between input and output: 1.5KVAC; Input and ground: 1.5KVAC; Output and ground: 0.5KVDC | |
| Electrical insulation resistance | Between input and output; input and ground; output and ground: 100M Ohms/500VDC | |
| Safety standard | Conforms to UL60950-1 | |
| EMC standard | Conforms to EN55022, Class A | |
| Size | 215*115*30mm/1.04L*H | |
| Package | 0.85kg/20pcs/18.5kg/0.041m³ | |

Certifications:
The ZJIVNV power supply is certified with CE and FCC, ensuring compliance with relevant safety and electromagnetic compatibility standards.

7. User Tips
- Check Input Voltage Switch: Always double-check the 115V/230V switch setting to match your local power grid before plugging in the unit. This is a common oversight that can lead to damage.
- Ensure Proper Ventilation: For optimal performance and longevity, ensure the power supply is installed in an area with unblocked airflow. Adequate ventilation helps the internal fan dissipate heat effectively.
- Battery Connection Safety: While the unit has fuse protection against reverse battery connection, always connect batteries with correct polarity to avoid unnecessary fuse replacements and ensure reliable operation.
- Stable Power Source: If your AC power source is prone to fluctuations, consider using an external voltage stabilizer or surge protector to safeguard the power supply and connected equipment.
8. Warranty and Support
This ZJIVNV power supply comes with a 1-year warranty from the date of purchase, covering manufacturing defects. For any issues or support, please contact the seller, Zhi Jiu Electric Store.
In addition to the warranty, the product is covered by certain guarantees:
- Refund if the package is lost.
- Refund if items are damaged upon arrival.
- Refund if no delivery within 30 days.
For further documentation, including a detailed user manual in PDF format, please refer to the official product page or contact customer support. View User Manual (PDF)