1. Introduction
The GEYA GPS8-05 is a current/voltage protective device designed for household equipment. It integrates metering functions and provides comprehensive protection against overvoltage, undervoltage, and overcurrent conditions. This device utilizes special metering chips to accurately detect voltage, current, electricity, and power levels, ensuring reliable monitoring and protection for your electrical systems.
1.1. Applications
- Overvoltage protection for household equipment.
- Undervoltage protection for household equipment.
- Overcurrent protection for household equipment.
1.2. Function Features
- Utilizes special metering chips for precise detection of voltage, current, electricity, and power.
- Provides real-time voltage and current monitoring and protection.
- Features a double bus wiring design for enhanced capability.
- Allows setting of custom overvoltage, undervoltage, and overcurrent values.
- Automatically resets after a fault condition.
- Equipped with a digital display for voltage and current values, and LED indicators for fault status.
2. Safety Information
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel.
- Always disconnect power before installing or servicing the device.
- Ensure all wiring connections are secure and comply with local electrical codes.
- Do not operate the device if it appears damaged.
- This product does not have an isolation function. Always disconnect the superior Miniature Circuit Breaker (MCB) during maintenance to prevent electrical hazards.
3. Specifications
| Parameter | Value |
|---|---|
| Function | Over voltage, under voltage and over current |
| Rated supply voltage | AC220V (L-N) |
| Rated supply frequency | 45-65Hz |
| Operation voltage range | 80V-400V (L-N) |
| Rated operational current | 32A, 40A, 63A, 80A (AC1) |
| Burden | AC max. 3VA |
| Over voltage operation value | OFF, 230V~300V |
| Under voltage operation value | 140V~210V, OFF |
| Over/under voltage action delay | 0.1s~10s |
| Over current operation value | 1A~32A/40A/50A/63A |
| Over current action delay | 2s~600s |
| Power-up delay | 2s~600s |
| Reset time | 2s~900s |
| Measurement error | ≤1% |
| Electrical life (AC1) | 1 x 104 |
| Mechanical life | 1 x 106 |
| Operating temperature | -20°C ~ +60°C |
| Storage temperature | -35°C ~ +75°C |
| Mounting/DIN rail | Din rail EN/IEC 60715 |
| Protection degree | IP40 for front panel/IP20 terminals |
| Operating position | any |
| Overvoltage category | III |
| Pollution degree | 2 |
| Dimensions | 82 x 36 x 68mm |
| Weight | 135g |
3.1. Parameter Setting Details
The device allows for detailed parameter configuration. Refer to the diagram below for a visual guide to setting various operational values and delays.

Text description for non-visual users: This image displays a flow chart for parameter setting, including overvoltage, undervoltage, overcurrent values, and various time delays. It also shows how to manually open/close the load, power-on/reset delay countdown, and query electricity and power consumption.
3.2. Panel and Function Diagrams
The following diagram illustrates the device's panel layout, including indicators and buttons, as well as a functional diagram showing the protection logic.

Text description for non-visual users: This image shows the front panel of the GPS8-05 device with its LCD display, LED indicators for overvoltage (>U), undervoltage (I), and control buttons (M, Up, Power). It also includes a detailed functions diagram illustrating the timing and sequence of protection actions based on voltage and current thresholds.
4. Installation
4.1. Mounting
The GEYA GPS8-05 is designed for DIN rail mounting (EN/IEC 60715). Ensure the device is securely clipped onto the DIN rail in a suitable enclosure.

Text description for non-visual users: A side view of the GEYA GPS8-05 device, highlighting the integrated clip for DIN rail mounting.
4.2. Wiring
Connect the device according to the wiring diagram provided. Ensure proper connection of the input (power supply) and output (load) terminals. The input terminals are marked 'N' and 'IN' at the top, and the output terminals are 'N' and 'Load' at the bottom.

Text description for non-visual users: This image includes a wiring diagram for the GPS8-05 device, showing connections for the neutral (N) and live (L) lines for both input and output. For GPS8-05U, the input is at the top (N, IN) and output at the bottom (N, Load). For GPS8-05D, the input is at the bottom (N, IN) and output at the top (N, Load).
Watch the video below for a visual guide on connecting the power supply and load.
Text description for non-visual users: A video demonstrating the wiring process for the GEYA GPS8-05 device, showing how to connect the power supply and the load (a light bulb) to the device terminals.
5. Operation
5.1. Parameter Setting
To enter parameter setting mode, long press the 'M' button for 3 seconds. Use the 'Up' (▲) and 'Down' (▼) buttons to adjust values. Short press 'M' to move to the next parameter. Long press 'M' for 3 seconds at any time to exit and save settings. If no key is operated for 60 seconds, the device will automatically exit the setting mode.
The parameters you can set include:
- Overcurrent setting: OFF, 1A-32A/40A/50A/63A (depending on model)
- Overvoltage operation value: OFF, 230V~300V
- Overvoltage recovery value: 225V~295V
- Undervoltage operation value: 140V~210V, OFF
- Undervoltage recovery value: 145V~215V
- Over/under voltage fault action time: 0.1s~10s
- Power up delay: 2s~600s
- Reset time: 2s~900s
- Fault reset: ON-OFF
- LCD backlight time: 10s~900s, ON
5.2. Manual Control (Open/Close)
During normal operation, the load can be switched ON or OFF manually by pressing the power key (⏻) for 0.5 seconds.
5.3. Power-on and Reset Delay
During power-on and fault reset, the product will count down and display the delay time. The load will be connected once the countdown ends.
5.4. Query Electricity & Power
The device can display current voltage, current, power, and total electricity consumption (kWh). Use the 'Up' (▲) button to cycle through these displays.
6. Maintenance
- Regularly inspect the device for any signs of physical damage or loose connections.
- Keep the device clean and free from dust and moisture.
- As noted in the safety information, this product does not have an isolation function. Always disconnect the superior Miniature Circuit Breaker (MCB) before performing any maintenance or inspection on the GPS8-05 device to ensure safety.
- In case of persistent issues, refer to the troubleshooting section or contact technical support.
7. Troubleshooting
7.1. Device Not Powering On
- Check the power supply connections to ensure they are secure and correctly wired.
- Verify that the main circuit breaker (MCB) supplying power to the device is ON.
- Ensure the rated voltage (220V AC) is present at the input terminals.
7.2. Load Not Activating After Power-on/Fault Reset
- The device has a configurable power-up delay and reset time. Wait for the displayed countdown to complete.
- Check the fault status LEDs. If any fault is indicated, address the underlying issue (overvoltage, undervoltage, or overcurrent).
- Ensure the 'Fault reset' parameter is set to 'ON' if automatic reset is desired.
7.3. Incorrect Voltage/Current Readings
- Verify that the wiring connections are correct and tight. Loose connections can lead to inaccurate readings.
- Ensure the device's rated operational current matches your application.
8. User Tips
- Input/Output Terminals: Pay close attention to the wiring diagram. For the GPS8-05U model, the input is typically from the top terminals (N, IN) and the output to the load is from the bottom terminals (N, Load). For the GPS8-05D model, the input is from the bottom and output from the top. Always double-check the markings on your specific device.
- Parameter Adjustment: When adjusting parameters, a short press of the 'Up' (▲) or 'Down' (▼) button changes the value incrementally, while a long press allows for quicker adjustment. Remember to long press 'M' to save your settings before exiting.
- Operating Temperature: The device is designed to operate within a temperature range of -20°C to +60°C. Ensure the installation environment stays within these limits for optimal performance and longevity.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact GEYA Official Store directly. Keep your purchase receipt or order details handy when contacting support.