1. Introduction
This manual provides essential information for the safe and efficient operation of your AUTONICS CX6M series counter timer. Please read this manual thoroughly before installation and use to ensure proper functionality and to prevent potential hazards.

This image shows a front view of the AUTONICS CX6M series counter timer, displaying its digital display for output, set value, and counter, along with 'RESET' and 'MODE' buttons and navigation keys.
2. Setup and Installation
Before installation, ensure the power supply is disconnected. Installation should be performed by qualified personnel.
2.1 Mounting
- The CX6M series is designed for panel mounting.
- Ensure adequate space around the unit for ventilation and wiring.
- Avoid locations subject to direct sunlight, excessive dust, corrosive gases, or strong vibrations.
2.2 Wiring
Refer to the wiring diagram provided with your specific model for precise connections. General wiring considerations include:
- Connect the power supply to the designated terminals.
- Connect input signals (e.g., from sensors, switches) to the counter input terminals.
- Connect output devices (e.g., relays, indicators) to the output terminals.
- Use appropriate wire gauges for all connections.
- Ensure all connections are secure to prevent loose contacts.
Note: Specific wiring diagrams vary by model (e.g., 1P2, 1P4, 2P2, 2P4). Always consult the diagram included with your product.
3. Operating Instructions
The CX6M series offers various counting and timing modes. Familiarize yourself with the front panel controls:
- Display: Shows current count/time, set value, and output status.
- RESET Button: Resets the counter or timer.
- MODE Button: Used to cycle through different operating modes and settings.
- Up/Down Arrows: Used to adjust set values and navigate menu options.
3.1 Basic Counter Operation
- Power On: Apply power to the unit.
- Select Mode: Press the MODE button to select the desired counting mode (e.g., Up, Down, Up/Down).
- Set Target Value: Use the Up/Down arrows to set the desired target count.
- Start Counting: The unit will begin counting based on input signals.
- Reset: Press the RESET button to clear the current count.
3.2 Basic Timer Operation
- Power On: Apply power to the unit.
- Select Mode: Press the MODE button to select the desired timing mode (e.g., On-delay, Off-delay).
- Set Time Value: Use the Up/Down arrows to set the desired time duration.
- Start Timing: The unit will begin timing upon activation of the start input.
- Output Activation: The output will activate/deactivate according to the selected timing mode and set value.
For detailed programming and advanced functions, refer to the full product manual (if available from Autonics).
4. Maintenance
The AUTONICS CX6M series counter timer is designed for reliable operation with minimal maintenance. Follow these guidelines:
- Cleaning: Gently wipe the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Inspection: Periodically check wiring connections for tightness and signs of wear or damage.
- Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
No user-serviceable parts inside. Do not attempt to open or repair the unit yourself.
5. Troubleshooting
If you encounter issues with your CX6M counter timer, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not power on | No power supply; incorrect wiring; blown fuse (internal) | Check power connections; verify wiring against diagram; contact support if fuse is suspected. |
| Counter not incrementing/decrementing | Input signal issue; incorrect input wiring; wrong operating mode selected | Verify input sensor/switch functionality; check input wiring; ensure correct counting mode is set. |
| Output not activating | Incorrect output wiring; output device malfunction; set value not reached/time not elapsed | Check output wiring; test output device; confirm set value and operating conditions. |
| Display shows error code | Internal malfunction; parameter setting error | Refer to the full product manual for specific error code meanings; try resetting the unit. |
6. Specifications
The AUTONICS CX6M series counter timers are designed for electrical DIY applications. Key specifications include:
- Product Type: Counter Timer
- Brand: AUTONICS
- Model Numbers: CX6M-1P4, CX6M-1P2, CX6M-2P4, CX6M-2P2
- DIY Supplies Category: Electrical
- Origin: Mainland China
- Package Dimensions (Approximate): Length: 20 cm, Width: 10 cm, Height: 10 cm
- Package Weight (Approximate): 0.1 kg
Note: Detailed electrical specifications (e.g., voltage, current, input frequency, output type) are specific to each model variant and should be referenced in the product's dedicated datasheet.
7. User Tips
Based on common user inquiries, here are some helpful tips:
- Communication Interfaces: Some users inquire about communication protocols like RS485. The CX6M series primarily functions as a standalone counter/timer. If RS485 communication is required, ensure you select a model variant specifically designed with this feature, as it is not standard across all CX6M models. Always check the detailed product specifications for communication options.
- Technical Data: For comprehensive technical data, including detailed wiring diagrams, input/output characteristics, and environmental ratings, always refer to the official Autonics datasheet or full user manual for your specific CX6M model.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized AUTONICS distributor or the manufacturer directly. Keep your purchase receipt and product model number handy when contacting support.
AUTONICS products are designed for industrial and electrical applications. Ensure proper installation and usage according to local electrical codes and safety standards.