1. Introduction
Thank you for choosing the EASUN POWER Modified Sine Wave Inverter. This device is designed to convert DC (Direct Current) power from a 12V or 24V battery into AC (Alternating Current) power, suitable for operating various household and electronic appliances. Featuring a modified sine wave output, UPS (Uninterruptible Power Source) functionality, and a three-phase charging system, it provides a reliable power solution for your needs. This manual provides essential information for the safe and efficient use of your inverter.
2. Safety Information
Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electrical shock, fire, or serious injury.
- Ensure proper ventilation around the inverter to prevent overheating.
- Do not expose the inverter to rain, moisture, or extreme temperatures.
- Keep flammable materials away from the inverter.
- Connect the inverter only to a DC power source with the correct voltage (12V or 24V).
- Always connect the battery terminals with correct polarity (red to positive, black to negative). Reverse polarity can damage the inverter and battery.
- Do not open the inverter casing. There are no user-serviceable parts inside.
- Disconnect the inverter from the battery and AC power before performing any maintenance or cleaning.
- Ensure all connections are tight and secure to prevent arcing and overheating.
3. Product Overview
3.1 Components and Features
The EASUN POWER Inverter is equipped with various features for safe and efficient power conversion and charging:
- Modified Sine Wave Output: Provides stable AC power for most electronic devices.
- DC 12V/24V Input: Compatible with standard automotive or solar battery systems.
- AC 110-240V Output: Versatile output voltage to suit different regional requirements.
- UPS Functionality: Acts as an Uninterruptible Power Source when connected to mains power and a battery.
- Three-Phase Charging: Utilizes constant current, constant voltage, and floating charge methods for optimal battery health.
- Smart Fan Cooling: Automatically activates based on internal temperature and load to maintain optimal operating conditions.
- Comprehensive Protection: Includes overload, overtemperature, high/low input voltage, reverse connection, and short circuit protection.
- USB Output: (Available on some models) Provides 5V DC power for charging mobile devices.
3.2 Inverter Layout and Controls
Familiarize yourself with the ports and controls of your inverter model:
- Power switch: Turns the inverter ON/OFF.
- AC output socket: Connect your AC appliances here.
- Battery voltage monitor: Displays the current battery voltage.
- Output voltage monitor: Displays the AC output voltage.
- Power indicator: Illuminates when the inverter is powered on.
- Inverter indicator: Indicates inverter operation status.
- Charging indicator: Illuminates when the battery is charging.
- 5V indicator: Illuminates when the 5V USB output is active.
- 5V interface: USB port for charging small electronic devices.
- AC input interface: Connect to mains AC power for UPS function and battery charging.
- AC output interface: Additional AC output socket (may vary by model).
- Overload protection switch: Resets the inverter after an overload event.
- Positive (Red) terminal: Connects to the positive terminal of the battery.
- Negative (Black) terminal: Connects to the negative terminal of the battery.
- Smart FAN: Cooling fan for temperature regulation.
Specific models may have slight variations in layout and dimensions:
4. Specifications
The following table details the specifications for the various EASUN POWER Modified Sine Wave Inverter models:
| Feature | PJ-800W | PJ-1000W | PJ-2000W | PJ-6000W |
|---|---|---|---|---|
| Rated Power (Continuous) | 350W | 500W | 1000W | 3000W |
| Peak Power | 800W | 1000W | 2000W | 6000W |
| Frequency | 50Hz/60Hz (Optional) | |||
| Wave Form | Modified Sine Wave | |||
| Input Voltage | 12V/24V (Optional) | |||
| Output Voltage | 110/120/220/230/240V (Optional) | |||
| Efficiency | ≥90% | |||
| Battery type | Lead acid battery | |||
| Charging mode | Three-phase charging method (constant current, constant voltage, floating charge) | |||
| Conversions time | ≤20mS | |||
| 5V USB Output | NO | YES | YES | YES |
| Cooling Mode | Smart fan (Automatic startup of high temperature and load) | |||
| Charge Protection | Input high voltage protection, input low voltage protection, short circuit protection, high temperature protection, overload protection | |||
| Working Temperature | 0-40°C | |||
| Working Humidity | 20-90%RH | |||
| Size (MM) | 242*95*54 | 203*140*64 | 248*140*64 | 454*180*142 |
| Gross weight (KG) | 1.02 | 1.6 | 1.83 | 6.83 |
5. Setup
Follow these steps to correctly set up your inverter:
5.1 Battery Connection
- Ensure the inverter's power switch is in the OFF position.
- Connect the red cable to the inverter's positive (+) terminal and the battery's positive (+) terminal.
- Connect the black cable to the inverter's negative (-) terminal and the battery's negative (-) terminal.
- For 24V systems, connect two 12V batteries in series as shown in the diagram.
- Ensure all connections are tight and secure.
5.2 System Connection (Mains and Load)
For UPS functionality and battery charging from mains power, connect the inverter as follows:
- Connect the inverter's AC input interface to a standard AC mains outlet.
- Connect your electrical loads (appliances) to the inverter's AC output socket(s).
5.3 Solar System Connection (6000W Model Example)
For models supporting solar input, connect your solar panels and charge controller as shown:
6. Operating Instructions
6.1 Powering On/Off
- To Power On: After ensuring all connections are secure, switch the inverter's power switch to the ON position. The power indicator will light up.
- To Power Off: Disconnect all AC loads, then switch the inverter's power switch to the OFF position.
6.2 Monitoring
The inverter features displays and indicators to monitor its status:
- Battery Voltage Monitor: Check the DC input voltage from your battery.
- Output Voltage Monitor: Verify the AC output voltage supplied to your appliances.
- Indicators: Observe the Power, Inverter, Charging, and 5V indicators for operational status.
6.3 Using the UPS Function
When the inverter is connected to both a battery and mains AC power, it functions as a UPS:
- Under normal conditions, the inverter will pass through mains AC power to your connected loads and charge the battery using its three-phase charging method.
- In case of a mains power outage, the inverter will automatically switch to battery power, providing uninterrupted AC power to your loads.
- When mains power is restored, the inverter will switch back to mains power and resume charging the battery.
6.4 Charging External Devices (5V USB)
If your inverter model includes a 5V USB interface, you can use it to charge compatible electronic devices:
- Connect your device's USB charging cable to the inverter's 5V interface.
- The 5V indicator will illuminate when the output is active.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter:
- Cleaning: Keep the inverter clean and free from dust and debris. Use a dry cloth to wipe the exterior. Do not use liquid cleaners.
- Ventilation: Ensure the cooling fan and ventilation openings are not blocked. The smart fan will automatically activate when needed.
- Connections: Periodically check all electrical connections (battery terminals, AC input/output) to ensure they are tight and free from corrosion.
- Battery Health: Monitor your battery's health and charge level regularly. The inverter's three-phase charging helps maintain battery life, but external battery maintenance may still be required based on battery type.
- Storage: If storing the inverter for an extended period, ensure it is fully charged and stored in a cool, dry place.
8. Troubleshooting
If you encounter issues with your inverter, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No power output / Inverter not turning on |
|
|
| Overload protection activated |
|
|
| Overtemperature protection activated |
|
|
| High/Low input voltage protection |
|
|
9. User Tips & FAQ
9.1 User Tips
- Appliance Compatibility: While modified sine wave inverters are suitable for most resistive loads (e.g., lights, heaters), some sensitive electronics or inductive loads (e.g., motors, refrigerators) may perform better with pure sine wave inverters. Check your appliance's requirements if you experience issues.
- Battery Sizing: Ensure your battery bank capacity is sufficient for your intended use. A larger battery capacity will allow for longer operation times.
- Cable Gauge: Use appropriately sized cables for connecting the inverter to the battery to minimize voltage drop and ensure efficient power transfer.
9.2 Frequently Asked Questions
- Q: Does this inverter have a battery charging function?
- A: Yes, this inverter features a three-phase charging method (constant current, constant voltage, floating charge) to charge connected lead-acid batteries when mains AC power is available.
- Q: Is this inverter suitable for 110V outlets?
- A: Yes, the inverter supports multiple output voltages, including 110V, 120V, 220V, 230V, and 240V, depending on the model and configuration. Please ensure you select the correct output voltage for your region.
10. Warranty and Support
EASUN POWER products come with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use. It does not cover damage caused by misuse, improper installation, unauthorized modifications, or natural disasters.