1. Introduction
The JK Jikong Parallel BMS Battery Protection Board is an intelligent management system designed for large-capacity series lithium battery packs, particularly for energy storage applications. It integrates advanced features such as voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and temperature protection. This BMS ensures the safe and reliable operation of your energy storage system by actively monitoring and managing battery health. It supports parallel use and various communication protocols including Bluetooth, CAN, and RS485, making it compatible with a wide range of inverters.

Key Features
- Active Balance Function (1A/2A)
- LED Status Indication
- APP Bluetooth Operation (Android, Apple, HarmonyOS)
- Over-voltage and Over-current Protection
- Support PC Upper Computer Operation
- Information Display
- Support RS485 / CAN / RS232 Communication
- High-precision Voltage Acquisition (±5mV)
- Battery Capacity Estimation
- High-precision Current Acquisition
- Accurate Time Logging
- Isolated Power Supply Circuit
- Short-circuit Protection
- 4-channel Temperature Detection Protection
- MOS Temperature Detection Protection
- Heating Function
- Parallel Charging Current Limiting (10A)
- Address DIP Switch (4 digits)
- Two Dry Contacts
2. Product Overview & Models
The protection board utilizes energy transfer active balancing technology to achieve a maximum continuous balance current of 1A or 2A, ensuring battery consistency and extending battery life. It is compatible with Li-ion (7S-16S), LiFePO4 (8S-16S), and LTO (14S-16S) battery types. The V19 version includes an integrated 10A parallel current limiting module.

Structural Block Diagram

Application Scenarios

3. Setup & Installation
Components Included

The standard package includes:
- 1x Main Unit
- 1x Communication Board (JK-CN-Link)
- 4x M6*10 Screws
- 1x Interface Transfer Cable (HY2.0-XH2.54-22AWG-30CM)
- 1x Interface Transfer Cable (2XH2.54-22AWG-30CM)
- 1x Interface Transfer Cable (IDC2.54mm-20P-30CM)
- 1x Dry Contact Terminal (WJ15EDGK-3.81-4P)
- 1x RJ45 Network Cable (CAT5E-8P twisted pair-40CM)
- 4x Balancing Sampling Wires (HY2.0-7P-22AWG-90CM-1, HY2.0-6P-Blue Shell-22AWG-90CM-2, HY2.0-7P-Red Shell-22AWG-90CM-3, HY2.0-6P-Yellow Shell-22AWG-90CM-4)
- 1x Device Activation Switch (GH1.25-6P-50CM terminal wire)
- 1x Energy Storage Board Power Cable (18AWG-Red-50CM + M3 Copper Nose)
- 1x Heating Wire (OT2.5-3-14AWG-150MM-Double Head)
Interface Definition
The BMS features various connectors for communication, display, and control. Refer to the diagrams below for detailed pin definitions.

Wiring Diagrams
Ensure all connections are made correctly before powering on the BMS. Incorrect wiring can lead to malfunction or damage.
8S Wiring Diagram

16S Wiring Diagram

Installation Method
The JK-PB1/2A16S-10/15/20P series protection board is suitable for 7-16 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. Always ensure the balance cables are properly connected and the P- and B- terminals are correctly wired. Securely fix the protection board to the battery core before powering it on.

Parallel Connection Setup
The parallel function allows multiple energy storage series protection boards to be monitored simultaneously by a host computer via the RS485 bus. To use this function, you will need a USB to RS485 serial port cable and the Jikong upper computer software.
The parallel function supports up to 16 BMS units. Each BMS must have a unique address (0-15). BMS with address 0 acts as the host, and BMS units with addresses 1-15 act as slaves. The host computer connects to the host BMS via a USB to RS485 serial port cable. The BMS addresses are set using the DIP switches on the interface board.
DIP Switch Settings for Addressing
The DIP switches are used to set the address of each BMS unit. Refer to the table below for common settings:
| Address | DIP Switch 1 | DIP Switch 2 | DIP Switch 3 | DIP Switch 4 |
|---|---|---|---|---|
| 0 (Host) | OFF | OFF | OFF | OFF |
| 1 (Slave) | ON | OFF | OFF | OFF |
| 2 (Slave) | OFF | ON | OFF | OFF |
| ... | ... | ... | ... | ... |
| 15 (Slave) | ON | ON | ON | ON |

4. Operating Instructions
APP Installation
The mobile APP for the BMS supports Android, Apple, and HarmonyOS. Android Version 7 or higher is required. Scan the QR code below to download the APP.

Device Activation
The protection board does not have a power-on control switch. It is designed for charging activation, meaning the charger voltage must be 2V higher than the battery voltage to activate the BMS. Alternatively, the device can be activated via a button or by connecting an optional display screen.
Parameter Setting
All operational parameters, including battery type, cell count, capacity, equalization trigger differential pressure, voltage calibration, and current calibration, can be configured through the Jikong APP. Refer to the 'Instructions for Setting Protection Board Parameters' in the full PDF manual for detailed guidance.
Active Equalization
The active equalization function transfers energy from high-voltage cells to low-voltage cells. Users can set the balance trigger pressure difference (mV) in the APP. Equalization automatically starts when the pressure difference between any two battery strings exceeds the set value and stops when it falls below the set value. The default balance current is 1A/2A, adjustable based on battery capacity. This function can be toggled on/off in the BMS control page of the APP.
Heating Function
The BMS includes a heating function to warm the battery in low-temperature conditions, preventing reduced charging/discharging efficiency. The heating current is 10A. It is recommended to use a temperature control switch (45°C to 65°C normally closed) in series with the heating circuit for secondary protection. The heating function can be controlled via the APP.Dry Contact Function
Two dry contacts are provided for controlling external devices like alarms or cooling fans. Users can select two trigger conditions in the APP (e.g., overtemperature, overcharge, overdischarge) to activate these contacts.
Discharge Precharge Function
The BMS supports a discharge precharge function with a default precharge time of 5 seconds. This can be enabled or disabled as needed via the APP.
LED Indicators
The interface board features LED indicators to show the BMS's working status and remaining battery power. The table below describes the LED behavior:
| Status | Normal/Alarm/Protection | RUN | ALM | L1-L6 (Battery Display) | Instructions |
|---|---|---|---|---|---|
| Power Off | Normal | OFF | |||
| Balance | Normal | ON (flicker) | OFF | Battery based display | |
| Charging | Overcurrent, Overtemp, Overvoltage, Charging Failure | flicker | flicker | Battery based display | |
| Discharging | Overcurrent, Overtemp, Undervoltage, Discharge Failure | flicker | flicker | Battery based display | |
| Other Alarm | Password not changed, Short circuit, Temperature abnormal | flicker | flicker | Battery based display |
Communication Functions (CAN, RS485)
The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate protocol in the APP based on their inverter brand and specifications. The BMS has two RS485 communication interfaces: RS485-1 for communication with inverters and other settings, and RS485-2 for parallel connection and communication with a host computer. The default baud rate is 115200.

APP Interface Demonstration
Video demonstrating the Jikong BMS mobile application interface for monitoring battery cell data and adjusting settings.
5. Maintenance
Intelligent Sleep Function
The BMS is equipped with an intelligent sleep function to reduce its own energy consumption when in standby mode (charging/discharging current less than 1A for 26 consecutive hours). This function can be enabled or disabled via the APP. To reactivate the BMS from sleep, you can press a button or connect a charger.
6. Troubleshooting
Protection Mechanisms
- Overcharge Protection: The BMS will stop charging if any cell voltage exceeds the set overcharge protection voltage. Charging resumes when all cell voltages drop below the recovery voltage.
- Discharge Undervoltage Protection: Discharging stops if any cell voltage falls below the set undervoltage protection voltage. Discharging resumes when all cell voltages rise above the recovery voltage. The BMS will automatically shut down if any cell voltage drops below the automatic shutdown voltage.
- Overcurrent Protection (Charge/Discharge): If the charging or discharging current exceeds the set continuous current for a specified delay time, the BMS will trigger overcurrent protection and stop the operation. It will resume after the overcurrent release time.
- Overtemperature Protection: The BMS will stop charging/discharging if the temperature exceeds the set overtemperature protection value. Operation resumes when the temperature falls below the recovery value.
- Low Temperature Protection: The BMS will stop charging if the temperature falls below the set low temperature protection value. Charging resumes when the temperature rises above the recovery value. For extremely cold environments, using the heating function is recommended.
- Short Circuit Protection: The BMS has built-in short-circuit protection. If a short circuit occurs during initial charging or connecting a load, increasing the short circuit protection delay in the APP may resolve the issue, especially if caused by high instantaneous currents from large capacitors in the load.
Emergency Switch
In case of issues like overtemperature, overdischarge, overcharge, or cell string drop during normal use, activating the emergency switch in the APP's BMS control page will enable charging and discharging for 30 minutes. This provides a temporary operational window, even if a single cell reaches the automatic shutdown voltage, to prevent critical situations.
User Tips
- Bluetooth Connectivity: Some users have reported Bluetooth connectivity issues after a period of use. It is advisable to thoroughly test the Bluetooth connection upon initial setup and ensure the BMS firmware is up to date. If persistent issues occur, contact support.
7. Specifications
General Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-70 | V |
| Standby Power Consumption | 12 | mW |
| Operating Power Consumption | 1100 | mW |
| Operating Temperature | -30 to 70 | °C |
| Max. Number of Collection Strings | 16 | S |
| Max. Balancing Current | 1 or 2 | A |
| Max. Charging Current (10P/15P/20P) | 100/150/200 | A |
| Max. Discharge Current (10P/15P/20P) | 100/150/200 | A |
| Max. Instantaneous Current (10P/15P/20P) | 200/300/400 | A |
| Max. Internal Loop Resistance (10P/15P/20P) | 1/0.45/0.35 | mΩ |
| Protective Plate Size | 300x100x24 | mm |
| Finished Weight | 1000 | g |
Product Dimensions

Interface Board Dimensions
8. Warranty & Support
For detailed warranty information and technical support, please refer to the official product documentation provided by Chengdu Jikong Technology Co., Ltd. or contact your vendor.