1. Preface
Thank you for purchasing a LEFOO Air Compressor Pressure Switch. This manual provides essential information for the safe and proper installation, operation, and maintenance of your device. Please read it carefully before use and retain it for future reference.
2. Safety Warnings
- WARNING: Risk of electric shock. Do not open or disassemble the device. No user-serviceable parts are inside. All electrical work should be performed by qualified personnel.
- CAUTION: Do not expose the switch to water, excessive moisture, or extreme temperatures outside its specified operating range.
- Do not use near flammable gases or explosives.
- Ensure the air compressor system is depressurized and electrically isolated before installation or maintenance.
- Always wear appropriate personal protective equipment (PPE) when working with air compressor systems.
3. Product Overview
The LEFOO Air Compressor Pressure Switch is designed to automatically regulate the pressure in air compressor systems by controlling the motor. It features a robust housing and a clear ON/OFF control knob for manual operation.
Figure 1: Front view of the pressure switch, showing the manual ON/OFF control knob.
The switch is available in various configurations, including single-hole and four-hole air inlet connections, to suit different compressor setups.
Figure 2: Comparison of single-hole (bottom) and four-hole (top) pressure switch variants.
4. Technical Specifications
The LEFOO pressure switches come in several models with varying pressure ranges and connection types. Refer to the table below for detailed specifications.
| Model Type | Connection Type | Pressure Range | Electrical Rating |
|---|---|---|---|
| LF18-1H | Single Hole | 3-11 bar (approx. 43-160 PSI) | 16A AC-3, 400V-4KW |
| LF18-4H | Four Holes | 3-11 bar (approx. 43-160 PSI) | 16A AC-3, 400V-4KW |
| LF18-1H (High Pressure) | Single Hole | 4-16 bar (approx. 58-232 PSI) | 16A AC-3, 400V-4KW (typical) |
| LF16 | Varies | 2.2-3.6 bar (approx. 32-52 PSI) | Varies by specific model |
| LF16 (Low Pressure) | Varies | 1.6-2.8 bar (approx. 23-41 PSI) | Varies by specific model |
Note: Some models may feature a meter valve for additional control.
Figure 3: Approximate dimensions of the pressure switch (60mm width, 100mm height).
5. Installation & Setup
Installation should only be performed by a qualified technician. Ensure the air compressor system is completely shut down, depressurized, and disconnected from power before proceeding.
5.1 Mounting
Mount the pressure switch in a stable location, free from excessive vibration and moisture. Ensure easy access for wiring and future adjustments.
5.2 Air Line Connection
Connect the pressure switch to the air compressor's pressure line. Use appropriate thread sealant for a leak-free connection. The switch is available with single or multiple air inlets depending on the model.
Figure 4: Bottom view showing air inlet connections and typical pressure range markings (e.g., 5-8kgf/cm²).
5.3 Electrical Wiring
Connect the electrical wiring from the compressor motor and power supply to the terminals inside the pressure switch. Refer to the internal diagram and your compressor's wiring schematic for correct connections. Ensure all connections are secure and insulated.
Figure 5: Internal view showing electrical terminals and model identification.
5.4 Pressure Adjustment
Most LEFOO pressure switches allow for adjustment of the cut-in and cut-out pressure settings. This is typically done via internal adjustment screws. Consult the specific model's detailed instructions (often found in the linked PDF manual) for precise adjustment procedures. A common range observed is 5-8 kgf/cm² (approximately 71-114 PSI).
6. Operating Instructions
Once installed and wired correctly, the pressure switch operates automatically. It will turn the compressor motor ON when the pressure drops below the set cut-in point and OFF when it reaches the set cut-out point.
6.1 Manual ON/OFF Control
The pressure switch is equipped with a manual ON/OFF knob for convenient control of the compressor motor.
- To turn ON: Rotate the red knob to the 'ON' position. The compressor will start if the pressure is below the cut-in setting.
- To turn OFF: Rotate the red knob to the 'OFF' position. This will stop the compressor motor regardless of the pressure.
7. Maintenance & Care
- Regularly inspect the switch for any signs of wear, damage, or corrosion.
- Keep the switch clean and free from dust, dirt, and oil. Use a soft, dry cloth for cleaning. Do not use harsh chemicals or abrasive cleaners.
- Ensure all electrical connections remain tight and secure.
- Check for air leaks around the pressure switch connections periodically.
- Store in a cool, dry place when not in use for extended periods.
8. Troubleshooting
- Compressor does not start:
- Check if the manual ON/OFF knob is in the 'ON' position.
- Verify power supply to the compressor and switch.
- Ensure wiring connections are correct and secure.
- Check if the pressure in the tank is already above the cut-out setting.
- Compressor does not stop:
- Check if the pressure switch is faulty or stuck.
- Verify the cut-out pressure setting.
- Inspect for air leaks in the system that prevent pressure buildup.
- Inconsistent pressure regulation:
- Check for proper pressure adjustment.
- Inspect for debris or wear in the pressure sensing mechanism.
9. User Tips
- For optimal performance, ensure the pressure switch is installed in a location that minimizes exposure to direct sunlight and extreme temperature fluctuations.
- When adjusting pressure settings, make small incremental changes and test the compressor's operation to achieve the desired range.
- Consider adding a small air filter before the pressure switch's inlet to prevent debris from affecting its operation, especially in dusty environments.
10. Warranty & Support
Warranty Period: 12 months from purchase.
The warranty covers defects in materials and workmanship under normal use. It excludes damage resulting from misuse, water exposure, unauthorized repair, or accidents.
For support, please refer to the official seller's contact information or the provided user manual PDF for more details.
Additional Resources: A detailed user manual in PDF format may be available for download. Please check the product page or contact customer support for access to the document: User Manual (PDF)
11. FCC Statement (US)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.