1. Introduction
This manual provides essential information for the safe and efficient operation of your SUMRY RS Series Off-Grid Solar Inverter. The RS Series inverters are pure sine wave hybrid solar inverters designed for various applications, offering features such as MPPT solar charging, dual AC output, and intelligent battery management. Please read this manual thoroughly before installation and use.
The SUMRY RS Series Off-Grid Solar Inverter is available in various power ratings, including 1.8KW, 3KW, 3.8KW, and 6.2KW, supporting 12V, 24V, and 48V battery systems, and can also operate without a battery. It features a wide PV input voltage range of 55-450VDC and a frequency range of 50Hz/60Hz.

2. Safety Information
- All wiring must be performed by qualified personnel to ensure safety and proper operation.
- Install a DC circuit breaker between the inverter and the PV module.
- Use appropriate cable sizes for all connections to prevent overheating and ensure efficient power transfer.
- Ensure proper ventilation around the inverter to prevent overheating.
- Do not attempt to open or repair the inverter yourself. Refer to qualified service personnel.
- The inverter includes multiple protection features: Overload Protection, Overheating Protection, High/Low Voltage Protection, Battery Protection, Short Circuit Protection, Overcurrent Protection, Anti-Reverse Protection, and Power Failure Protection.

3. Product Overview
3.1. Operation and Display Panel
The inverter features an LCD display and four function keys (ESC, UP, DOWN, ENTER) for indicating operation status and input/output power information, and for navigating settings.
3.2. RGB Light Indicators (Optional)
- Green Light: Inverter state (normal operation).
- Blue Light: Utility state (power supplied by grid).
- Red Light: Failure state (error or fault detected).

3.3. Rear Panel Connections
The rear panel provides all necessary connection terminals for AC input, AC main output, AC EPS output, battery, and PV input.

4. Setup and Installation
4.1. Unboxing and Inspection
Carefully remove the inverter from its packaging. Inspect the unit for any signs of damage during transit. Ensure all components are present.
4.2. Basic System Architecture
The inverter integrates solar power (optional), generator or utility power, external battery packs, and home appliances into a hybrid power system. This allows for flexible power management and backup capabilities.

4.3. Wiring Connections
Refer to the rear panel diagram for correct wiring. Ensure all connections are secure and follow local electrical codes. The video below demonstrates the connection process.
Video: Unboxing and Connection Demonstration
4.3.1. PV Connection
CAUTION: Before connecting the PV module, install separately a DC circuit breaker between the inverter and PV module.
WARNING: All wiring must be performed by a qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below:
| Model | Wire Gauge | Torque Value |
|---|---|---|
| RS 2200 | 1 * 12 AWG | 1.2-1.6 Nm |
| RS 3200 | 1 * 10 AWG | 1.2-1.6 Nm |
| RS 4200 | 1 * 12 AWG | 1.2-1.6 Nm |
| RS 7000 | 1 * 12 AWG | 1.2-1.6 Nm |
4.3.2. PV Module Selection
- Open circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.
| Model | PV open circuit voltage | MPPT operating voltage range |
|---|---|---|
| RS 4200 | 450Vdc | 55Vdc~430Vdc |
| RS 7000 | 450Vdc | 55Vdc~430Vdc |

4.4. Battery Compatibility
The inverter is compatible with multiple battery types, including Flooded (FLD), Gel, Lithium-iron phosphate (LI), Lithium-ion (LI), AGM/Sealed (SLD), and user-customized batteries.

5. Operating Instructions
5.1. Function Keys
| Function Key | Description |
|---|---|
| ESC | Exit setup mode |
| UP | Skip to the previous setting |
| DOWN | Jump to the next setting |
| ENTER | Confirm the selected mode or enter the set mode |
5.2. Internal Clock Function
The inverter can utilize its internal clock function to manage solar power generation data and allow users to set AC charging times and load run times. This feature helps optimize energy usage based on electricity pricing or specific needs.
5.3. Setting Lithium Battery SOC Percentage
For lithium batteries, the inverter allows setting the State of Charge (SOC) percentage for various operational triggers:
- Program 01: SOC point for switching to the utility source input. Default values are 50% and 10%.
- Program 01: SOC point for switching to battery mode. Default values are 95% and 30%.
- Item 05 (LIB-485 selected): Battery low SOC shutdown point. Default values are 20% and 5%.

5.4. Monitoring and Control via App
The inverter supports monitoring and control via a smart application, available for download on app stores. An optional datalogger can be connected to facilitate this feature.

6. Maintenance
- Regularly inspect all wiring connections for tightness and signs of corrosion.
- Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating.
- Clean the exterior of the inverter with a dry, soft cloth. Do not use liquid cleaners.
- Periodically check the battery terminals for corrosion and clean if necessary.
- Ensure the environment around the inverter is dry and free from excessive humidity.
7. Troubleshooting
7.1. Status Indicators
The inverter's LCD display and RGB lights provide visual cues for its operational status. Refer to the table below for interpreting the status indicators:
| Status Indicator Icon | Indicating Information |
|---|---|
| AC / INV (Solid On) | Output is powered by utility in Line mode |
| AC / INV (Flashing) | In battery mode, the output is powered by battery or PV |
| CHG (Solid On) | The battery is fully charged |
| CHG (Flashing) | The battery is charging |
| FAULT (Solid On) | Fault occurs in the inverter |
| FAULT (Flashing) | Warning condition occurs in the inverter |

7.2. Common Issues and Solutions
- No Power Output: Check AC input, battery connections, and PV input. Verify circuit breakers are not tripped. Check for fault indicators.
- Battery Not Charging: Ensure PV modules are receiving sufficient sunlight and are correctly connected. Check charging current settings.
- Overload/Overheating: Reduce connected load. Ensure proper ventilation and clear any obstructions from cooling fans.
- Inverter Not Turning On: Verify battery voltage is within the acceptable range. Check all power connections.
8. Specifications
8.1. General Specifications (RS Series)
- Output Waveform: Pure Sine Wave
- Input Voltage: 230VAC
- Frequency Range: 50Hz/60Hz (Auto sensing)
- MPPT Operating Voltage Range: 55-450VDC
- Max. PV Array Open Circuit Voltage: 450Vdc
- Communication Ports: Two RS485 ports (one for BMS, another RS485/RS232 for remote monitoring/WiFi)
- Efficiency: Up to 98% Max.
- Battery Compatibility: Flooded, Gel, Lithium-iron phosphate, Lithium-ion, AGM/Sealed, User-customized
- Operation: Can work with or without battery
- Certifications: CE, FCC, RoHS
8.2. Model-Specific Specifications
| Feature | RS4200 (3.8KW/4.2KVA) | RS7000 (6.2KW/7KVA) |
|---|---|---|
| Rated Power | 3.8KW | 6.2KW |
| Surge Power | 8400VA | 14000VA |
| Battery Voltage | 24VDC / 48VDC | 48VDC |
| Max. Charging Current | 80A / 110A | 110A |
| Max. PV Array Power | 6KW | 6KW |
| Full Load | 3800W | 6200W |


9. User Tips
- The inverter supports 220V AC output, suitable for regions with this voltage standard.
- This inverter can operate without a battery, making it flexible for various solar setups.
- The inverter is compatible with both 24V and 48V battery systems, depending on the specific model variant.
- Utilize the internal clock function to schedule AC charging and load operation to take advantage of off-peak electricity rates.
- For optimal performance and battery longevity, configure the lithium battery SOC settings according to your battery manufacturer's recommendations.
10. Warranty and Support