1. Introduction

The PowMr POW-SunSmart 10K is a high-performance 10KW split-phase hybrid solar inverter designed for both on-grid and off-grid applications. It features dual MPPT (Maximum Power Point Tracking) technology with a 200A solar charger, providing efficient power conversion and management for 48V battery systems, with 110V and 220V AC output capabilities. This manual provides essential information for the safe installation, operation, and maintenance of your inverter.

2. Safety Information

  • Read all instructions and warnings in this manual before installation and operation.
  • Installation must be performed by qualified personnel in accordance with all local electrical codes.
  • Ensure the inverter is disconnected from all power sources (PV, battery, utility) before performing any maintenance or wiring.
  • Do not disassemble the inverter. There are no user-serviceable parts inside.
  • Avoid exposing the inverter to rain, snow, or liquids. Install in a dry, well-ventilated area.
  • The open circuit voltage of the PV panel in series connection must remain below 500V. Over-voltage will cause damage to the inverter and is not covered by warranty.

3. What's in the Box

Upon unpacking, please verify that all items are included and undamaged:

  • PowMr Hybrid Solar Inverter
  • Instruction Manual
  • Cable Lugs and Screws
Contents of the PowMr Hybrid Solar Inverter box, showing the inverter unit, instruction manual, and cable lugs with screws.
Figure 3.1: Package Contents

4. Specifications

CategoryParameterValue (POW-SunSmart 10K)
INVERTER OUTPUTRated Output Power10,000W
Max. Peak Power20,000W
Rated Output Voltage120/240Vac (split phase/single phase)
Load Capacity of Motors6HP
Rated AC Frequency50/60Hz
Wave formPure Sine Wave
Switch Time10ms (typical)
BATTERYBattery TypeLi-ion/ Lead-Acid/User Defined
Rated Battery Voltage48Vdc
Voltage Range40-60Vdc
Max. MPPT Charging Current200A
PV INPUTNum. of MPP Trackers2
Max. PV array power11,000W
Max. input current22/22A
Max. Voltage of Open Circuit500Vdc
MPPT Voltage Range125-425Vdc
MAINS/ GENERATOR INPUTInput Voltage Range90-140Vac
Frequency Range50/60Hz
Bypass Overload Current63A
EFFICIENCYMPPT Tracking Efficiency99.9%
Max. Battery Inverter Efficiency92%
GENERALDimensions620*445*130mm (2*1.5*0.4ft)
Weight27kg (59.5lb)
Protection DegreeIP20, Indoor Only
Operating Temperature Range-10~55℃ (>45℃ derated)
Cooling MethodInternal Fan
COMMUNICATIONEmbedded InterfacesRS485/CAN/USB/ Dry contact
External Modules (Optional)Wi-Fi /GPRS
CERTIFICATIONSafetyIEC62109-1, IEC62109-2, UL1741
EMCEN61000-6-1, EN61000-6-3, FCC15classB
RoHSYes

5. Product Overview

5.1 Inverter Components and Ports

Diagram showing the external components and ports of the PowMr Hybrid Solar Inverter, including LCD screen, LED indicators, touchable keys, ON/OFF switch, PV input, battery input, dry contact, CAN/RS485 ports, USB-B port, grounding screw, AC output, AC input, and AC input breaker.
Figure 5.1: Inverter Components and Ports

The inverter features a comprehensive set of ports and indicators for seamless integration into your solar power system:

  1. LCD screen
  2. LED Indicators
  3. Touchable key
  4. ON/OFF Rocker Switch
  5. PV INPUT (1/1)
  6. BAT INPUT (+)
  7. BAT INPUT (-)
  8. Dry contact
  9. CAN/RS485-2 port
  10. RS485-1 port
  11. USB-B port
  12. Grounding Screw
  13. AC OUT (L+L+N)
  14. AC IN (L+L+N)
  15. AC INPUT breaker

5.2 LCD HD Display Screen

The LCD screen provides real-time monitoring of photovoltaic system operating data. It displays various parameters including voltage, current, power, energy production (kWh), temperature, and operational status.

Detailed diagram of the LCD HD display screen showing various real-time data points like PV voltage, battery voltage, AC input voltage, load power, and system status indicators.
Figure 5.2: LCD HD Display Screen Overview

The display includes:

  • PV Side: Indicates PV panel status and voltage/current.
  • Batt Side: Shows battery status, voltage, and state of charge (SOC).
  • AC IN Side: Displays AC input voltage/frequency from utility or generator.
  • LOAD Side: Indicates power consumption by connected loads.
  • Inverter Status: Shows if the inverter is operating normally or in standby.
  • LED Indicators: FAULT, CHARGE, AC/INV LEDs for quick status checks.
  • Touchable Keys: Used for navigation and setting parameters (SET, UP/DOWN, ENTER).
Video 5.1: Demonstration of the LCD display showing real-time voltage, current, kWh, and temperature readings.

6. Setup

6.1 Wiring Diagrams

The PowMr POW-SunSmart 10K supports both Split-Phase and Single-Phase configurations. Ensure all wiring is done by a qualified electrician.

Split-Phase Mode (120V/240V)

Wiring diagram for Split-Phase Mode, showing connections for PV panels, 48V batteries, mains/generator input, and inverter output to a split-phase load. Includes voltage and current specifications.
Figure 6.1: Split-Phase Mode Wiring Diagram

Notice: The open circuit voltage of PV panels in series connection must be below 500V. Over-voltage will cause damage to the inverter. Damage caused by improper configuration is not covered by warranty.

Single-Phase Mode (120V)

Wiring diagram for Single-Phase Mode, illustrating connections for PV panels, 48V batteries, mains/generator input, and inverter output to a single-phase load. Includes voltage and current specifications.
Figure 6.2: Single-Phase Mode Wiring Diagram

Notice: The open circuit voltage of PV panels in series connection must be below 500V. Over-voltage will cause damage to the inverter. Damage caused by improper configuration is not covered by warranty.

6.2 Battery Compatibility

The inverter is compatible with 48V Lead-acid and Lithium batteries. It also supports batteryless operation, where the inverter can power loads directly from the PV array or AC grid without a battery connected. The battery charging current setting range is 0-200A.

Image showing the inverter's compatibility with various 48V battery types including AGM, GEL, FLD, LI, SLD, and USER-defined, along with batteryless operation capability.
Figure 6.3: Battery Compatibility

A dual activation function allows the inverter to trigger the activation of a dormant Li-ion battery via either mains or photovoltaic power supply access.

7. Operating Instructions

7.1 Time-Slot Charging/Discharging Function

The POW-SunSmart series is equipped with a time-slot charging and discharging function, allowing users to set different charging and discharging periods according to local peak and valley tariffs. This optimizes the use of utility power and PV energy, helping to save electricity costs.

Graph illustrating Peak-Valley Electricity Tariff and diagrams for Time-slot Utility/Charging Function and Time-slot Battery Discharging Function, each with three definable periods.
Figure 7.1: Time-Slot Charging/Discharging Function

Notice: Before using this function for the first time, please set the local time in parameter items 54, 55. Then, you can set the corresponding time slot according to the local peak and valley tariff charges.

7.2 Display Navigation and Settings

Use the touchable keys (SET, UP/DOWN, ENTER) on the LCD display to navigate through menus and adjust parameters. Refer to the detailed diagram in Section 5.2 for key functions.

8. Maintenance

8.1 Detachable Insect-Proof Screen

The inverter features a detachable insect-proof screen to prevent insects from entering and causing internal damage. Regularly clean the screen to maintain proper airflow and prevent overheating.

8.2 Intelligent Cooling Fans

Equipped with four cooling fans, the inverter ensures efficient heat dissipation and stable operation. Keep the fan vents clear of obstructions to allow for proper airflow.

Image showing the detachable insect-proof screen, intelligent cooling fans, dry contact ports, and Hall coil components of the inverter.
Figure 8.1: Maintenance Features

9. Troubleshooting

If the inverter is not functioning as expected, perform the following basic checks:

  • No Power: Check all AC input, DC battery, and PV connections. Ensure the ON/OFF rocker switch is in the 'ON' position.
  • No Output: Verify that the AC output breaker is not tripped. Check for any fault indicators on the LCD screen.
  • Overload Protection: The inverter has built-in overload protection. If an overload occurs, the inverter will attempt to resume output after a delay. Repeated overloads will cause the inverter to switch off until restarted. Refer to the specifications for detailed overload thresholds and recovery times.
  • Fault Indicators: Consult the LCD display and LED indicators for specific fault codes or warnings. Refer to the full product manual for a comprehensive list of fault codes and their remedies.
  • PV Input Issues: Ensure PV panels are receiving adequate sunlight and connections are secure. Check PV voltage and current on the LCD display.

For persistent issues, contact PowMr customer support.

10. User Tips

  • Simultaneous 110V and 220V Output: Yes, this inverter is designed to provide both 110V and 220V output simultaneously, making it suitable for a wide range of household appliances and RV setups.
  • Parallel Connection: The inverter includes a 'PARALLEL CONNECTION' port. For detailed instructions on connecting multiple units in parallel, please refer to the comprehensive installation guide provided with the product or contact PowMr technical support.
  • Optimizing Charging: Utilize the time-slot charging/discharging function to take advantage of off-peak electricity rates and maximize self-consumption of solar energy.
  • Monitoring: Regularly check the LCD display for real-time system performance and any alerts to ensure optimal operation.

11. Warranty and Support

The PowMr POW-SunSmart 10K Hybrid Solar Inverter comes with a 2-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service.

For technical support, warranty claims, or further assistance, please contact PowMr customer service through the official channels. Ensure you have your product model number (POW-SunSmart 10K) and purchase details ready.

The inverter supports various communication interfaces including RS485, CAN, USB, and Dry Contact for monitoring and control. Optional Wi-Fi/GPRS modules are available for enhanced remote monitoring capabilities.


Related Documents - POW-SunSmart 10K

Preview PowMr POW-SunSmart L3/PL3 Series User Manual
User manual for the PowMr POW-SunSmart L3 and PL3 series all-in-one hybrid solar inverters. This guide covers safety instructions, production overview, installation, connection, operation, communication, fault remedies, protection, maintenance, and parallel operation.
Preview PowMr POW-SunSmart Series User Manual: 8K, 10K, 8KP, 10KP Hybrid Solar Inverters
Comprehensive user manual for PowMr POW-SunSmart series hybrid solar charge inverters (8K, 10K, 8KP, 10KP). Covers installation, operation, safety, troubleshooting, and maintenance for efficient solar energy management in industrial and residential applications.
Preview PowMr POW-SunSmart Series User Manual: 8K, 10K, 8KP, 10KP Hybrid Solar Inverters
Comprehensive user manual for PowMr POW-SunSmart 8K, 10K, 8KP, and 10KP all-in-one solar charge inverters. Covers installation, connection, operation, safety, maintenance, and parallel configurations for hybrid solar energy systems.
Preview PowMr POW-SunSmart 8K/10K User Manual
User manual for the PowMr POW-SunSmart 8K, POW-SunSmart 10K, POW-SunSmart 8KP, and POW-SunSmart 10KP all-in-one solar charge inverters. This guide provides essential safety instructions, product details, installation procedures, operation guidelines, and troubleshooting information.
Preview PowMr POW-SunSmart 8K/10K Hybrid Solar Inverter User Manual
Comprehensive user manual for the PowMr POW-SunSmart 8K and 10K hybrid solar inverters. Covers installation, operation, safety, and maintenance for efficient solar energy management.
Preview PowMr POW-SunSmart L3 & PL3 Series Hybrid Solar Inverter User Manual
Comprehensive user manual for PowMr POW-SunSmart L3 and PL3 Series hybrid solar inverters. Covers installation, connection, operation, safety, troubleshooting, and technical specifications for efficient solar energy management.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.