1. Introduction
The JDY-24M Bluetooth module offers advanced networking capabilities, supporting Bluetooth 5.0 BLE Mesh functionality. It facilitates master-slave transparent transmission, iBeacon, BLE probe, and iBeacon detection. The MESH networking feature allows for up to 65535 device connections, utilizing multi-hop wireless anti-collision technology. It boasts a network communication speed of 50ms for sending 17 bytes of data. The module supports both routing nodes (for data relay, without low power consumption) and terminal nodes (with low power consumption, automatically sleeping after data transmission via button press).
Typically, setting up JDY-24M networking only requires configuring the network NETID and a short circuit address, after which the module automatically networks. When the networking module communicates with an application, it functions as a transparent transmission, simplifying application development for users, especially for compatibility with older products.
2. Product Features
- Supports transparent data transmission with mobile phone applications (iOS, Android) with a working current of approximately 1mA.
- Enables high-speed master-slave transparent transmission between modules.
- Includes iBeacon function with ultra-low power consumption.
- Supports iBeacon probe functionality.
- Supports BLE Bluetooth probe functionality.
- Features multi-link slave mode, allowing connection to multiple mobile phones simultaneously for data pass-through.
- Supports Bluetooth MESH for serial port data communication, output IO control, and input key-press events.
- MESH network data transmission supports both response and no-response communication modes.
- Enables network remote control capabilities.
3. Technical Specifications
| Type | Specifications and Parameters |
|---|---|
| Working Voltage | 1.9-3.6V |
| Operating Temperature | -40 - 85 °C |
| Maximum Transmit Power | +4 dBm |
| Antenna | PCB Antenna |
| Reception Sensitivity | -96 dBm |
| SMT Welding Temperature | <260 ℃ |
| Communication Interface | UART |
| Average Current | |
| Non-MESH mode wake-up (transparent transmission) current | ~1mA |
| Non-MESH mode slave broadcast light sleep | Within 200uA (related to broadcast interval) |
| MESH mode wake-up communication current | ~4mA |
| MESH mode sleep current | 3uA |
| Deep Sleep mode | 3uA |
4. Setup and Wiring
The JDY-24M module is a compact Bluetooth module designed for easy integration. Below are the dimensions and pinout for proper connection.


Pin Descriptions:
- STAT: Status indicator pin.
- TXD: Transmit Data pin (connect to RX of microcontroller).
- RXD: Receive Data pin (connect to TX of microcontroller).
- VCC: Power supply input (1.9-3.6V).
- GND: Ground connection.
Ensure correct voltage supply to VCC and proper UART connections (TXD to RX, RXD to TX) for communication with a microcontroller or other serial devices.
5. Operating Instructions
The JDY-24M module operates primarily through AT commands sent via its UART interface. The module supports various modes including transparent transmission, iBeacon, and MESH networking.
5.1. Factory Default Configuration
The module comes with the following default settings:
| Sequence | Function | Parameter | AT Command |
|---|---|---|---|
| 1 | Baud Rate | 115200 | AT+BAUD8 |
| 2 | Module Short Address | MAC address (2 bytes) | |
| 3 | Network ID Number | 1189 | AT+NETID1189 |
| 4 | K1 Target Short Address | FFFF | AT+KEY1,FFFF,1,1 |
| 5 | K2 Target Short Address | FFFF | AT+KEY2,FFFF21 |
| 6 | K3 Target Short Address | FFFF | AT+KEY3,FFFF31 |
| 7 | K4 Target Short Address | FFFF | AT+KEY4,FFFF41 |
| 8 | K5 Target Short Address | FFFF | AT+KEY5,FFFF51 |
| 9 | APP Password Switch | Off | AT+TYPE0 |
| 10 | APP Connection Password | 1234 | AT+PIN1234 |
| 11 | Broadcast Name | JDY-24M | AT+NAMEJDY-24M |
5.2. Serial Port AT Instruction Set
To configure the JDY-24M module, send AT commands via the serial port. Each AT command must be terminated with 'rn' (carriage return and newline).
| Sequence | Instruction | Function | Default |
|---|---|---|---|
| 1 | AT | Test commands | - |
| 2 | AT+RESET | Reset module | - |
| 3 | AT+VERSION | Query firmware version | - |
| 4 | AT+LADDR | Read MAC address | - |
| 5 | AT+NAME | Read and write broadcast name | JDY-24M |
| 6 | AT+PIN | Connection password settings | 1234 |
| 7 | AT+TYPE | Whether to open password connection method | 0 |
| 8 | AT+BAUD | Set baud rate | 115200 |
| 9 | AT+DISC | Disconnect | - |
| 10 | AT+STAT | Read connection status | 0 |
| 11 | AT+STARTEN | Boot sleep settings | 1 |
| 12 | AT+ADVINT | Set broadcast interval | 1 |
| 13 | AT+POWR | Set transmission power | 3 |
| 14 | AT+ROLE | Set operating mode | 0 |
| 15 | AT+SLEEP | Sleep instruction | - |
| 16 | AT+DEFAULT | Restore factory configuration | - |
| 17 | AT+INQ | Host search slave broadcast | - |
| 18 | AT+STOP | Stop broadcasting | - |
| 19 | AT+CONN | Connect to the scan list ID number | - |
| 20 | AT+CONA | Instructions MAC address | - |
| 21 | AT+BAND | Binding from machine MAC address | - |
| 22 | AT+CLRBAND | Clear binding | - |
| 23 | AT+SRBAND | Connect the slave with the strongest peripheral signal | - |
| 24 | AT+MESH | MESH - sends the data | - |
| 25 | AT+KEY | Key parameters | - |
| 26 | AT+NETID | Networking ID number of the configuration | 1189 |
| 27 | AT+MADDR | Networking short address | MAC address after two |
| 28 | AT+MCLSS | Networking device type | 0 (router) |
| 29 | AT+FRIEND | Add private friends MAC address | 000000000000 |
| 30 | AT+CLRFRIEND | Clear the private password friends | - |
| 31 | AT+FRTYPE | Friend types | 0 |
| 32 | AT+IBUUID | iBeacon UUID that identifies the configuration | - |
| 33 | AT+MAJOR | iBeacon MAJOR configuration | 000A |
| 34 | AT+MINOR | iBeacon MINOR configuration | 0007 |
| 35 | AT+IBSING | iBeacon SING configuration | - |
| 36 | AT+ENLOG | Serial output status switch | 1 (on) |
5.3. MESH Short Address Table (MADDR)
The MESH network uses short addresses for device identification and communication. A short address is equivalent to a device's ID number within the network.
| Address | Function | Description |
|---|---|---|
| 0XFFFF | Broadcast Address | The device short address cannot be configured as 0XFFFF. Broadcast data can be received by all devices in the network. |
| 0X0002 to 0XFF00 | Unicast Address | Device address. Users can set short addresses within this range. Unicast data can only be received by devices with specified addresses. |
| 0X0001 | Machine Center Address | Designated for the machine center. |
| 0xFF01 to 0XFFFE | System Address | Generally not recommended for user configuration. |
6. User Tips
- Always ensure the power supply voltage is within the specified range (1.9-3.6V) to prevent damage to the module.
- When using AT commands, remember to append 'rn' (carriage return and newline) to each command for proper interpretation by the module.
- For MESH networking, carefully plan your network ID (NETID) and short addresses (MADDR) to avoid conflicts and ensure reliable communication.
- If experiencing connectivity issues, try resetting the module using the AT+RESET command or restoring factory defaults with AT+DEFAULT.
- The PCB antenna is integrated; avoid obstructing it with metal enclosures or other components that could degrade signal strength.
7. Troubleshooting
- Module not responding to AT commands:
Check serial port connections (TXD/RXD swapped?), baud rate (default is 115200), and ensure commands are terminated with 'rn'. Verify power supply. - Cannot connect to the module:
Ensure the module is powered on and advertising (check STAT pin if available). If using a password, ensure it's correct (default 1234). Check if the module is in the correct operating mode (AT+ROLE). - Poor signal strength or range:
Ensure the PCB antenna is not obstructed. Test in an open environment. Check for sources of interference. - MESH network issues:
Verify all modules have the same NETID. Ensure unique short addresses (MADDR) are assigned to each device. Check the networking device type (AT+MCLSS). - Unexpected behavior:
Try restoring the module to factory default settings using the AT+DEFAULT command.
8. Maintenance
The JDY-24M module is a robust electronic component designed for long-term operation with minimal maintenance. Follow these guidelines:
- Environmental Conditions: Keep the module in a dry environment, away from moisture, dust, and corrosive substances. Operate within the specified temperature range of -40 to 85 °C.
- Cleaning: If cleaning is necessary, use a soft, dry cloth. Avoid using liquids or harsh chemicals.
- Handling: Handle the module with care to avoid physical damage to the PCB or components. Electrostatic discharge (ESD) precautions should be observed during handling.
- Firmware Updates: Check the manufacturer's website periodically for any available firmware updates that may improve performance or add new features.
9. Warranty and Support
For specific warranty information, please refer to the terms and conditions provided by your retailer or the manufacturer, SZYTF. Technical support may be available through the seller or manufacturer's official channels. Keep your purchase receipt for any warranty claims.