1. Introduction

The JDY-24M Bluetooth module offers advanced networking capabilities, supporting Bluetooth 5.0 BLE Mesh functionality. It facilitates master-slave transparent transmission, iBeacon, BLE probe, and iBeacon detection. The MESH networking feature allows for up to 65535 device connections, utilizing multi-hop wireless anti-collision technology. It boasts a network communication speed of 50ms for sending 17 bytes of data. The module supports both routing nodes (for data relay, without low power consumption) and terminal nodes (with low power consumption, automatically sleeping after data transmission via button press).

Typically, setting up JDY-24M networking only requires configuring the network NETID and a short circuit address, after which the module automatically networks. When the networking module communicates with an application, it functions as a transparent transmission, simplifying application development for users, especially for compatibility with older products.

2. Product Features

  • Supports transparent data transmission with mobile phone applications (iOS, Android) with a working current of approximately 1mA.
  • Enables high-speed master-slave transparent transmission between modules.
  • Includes iBeacon function with ultra-low power consumption.
  • Supports iBeacon probe functionality.
  • Supports BLE Bluetooth probe functionality.
  • Features multi-link slave mode, allowing connection to multiple mobile phones simultaneously for data pass-through.
  • Supports Bluetooth MESH for serial port data communication, output IO control, and input key-press events.
  • MESH network data transmission supports both response and no-response communication modes.
  • Enables network remote control capabilities.

3. Technical Specifications

TypeSpecifications and Parameters
Working Voltage1.9-3.6V
Operating Temperature-40 - 85 °C
Maximum Transmit Power+4 dBm
AntennaPCB Antenna
Reception Sensitivity-96 dBm
SMT Welding Temperature<260 ℃
Communication InterfaceUART
Average Current
Non-MESH mode wake-up (transparent transmission) current~1mA
Non-MESH mode slave broadcast light sleepWithin 200uA (related to broadcast interval)
MESH mode wake-up communication current~4mA
MESH mode sleep current3uA
Deep Sleep mode3uA

4. Setup and Wiring

The JDY-24M module is a compact Bluetooth module designed for easy integration. Below are the dimensions and pinout for proper connection.

JDY-24M Bluetooth module dimensions
Figure 1: JDY-24M Bluetooth Module Dimensions (27mm x 12.9mm)
JDY-24M Bluetooth module pinout
Figure 2: JDY-24M Bluetooth Module Pinout (STAT, TXD, RXD, VCC, GND)

Pin Descriptions:

  • STAT: Status indicator pin.
  • TXD: Transmit Data pin (connect to RX of microcontroller).
  • RXD: Receive Data pin (connect to TX of microcontroller).
  • VCC: Power supply input (1.9-3.6V).
  • GND: Ground connection.

Ensure correct voltage supply to VCC and proper UART connections (TXD to RX, RXD to TX) for communication with a microcontroller or other serial devices.

5. Operating Instructions

The JDY-24M module operates primarily through AT commands sent via its UART interface. The module supports various modes including transparent transmission, iBeacon, and MESH networking.

5.1. Factory Default Configuration

The module comes with the following default settings:

SequenceFunctionParameterAT Command
1Baud Rate115200AT+BAUD8
2Module Short AddressMAC address (2 bytes)
3Network ID Number1189AT+NETID1189
4K1 Target Short AddressFFFFAT+KEY1,FFFF,1,1
5K2 Target Short AddressFFFFAT+KEY2,FFFF21
6K3 Target Short AddressFFFFAT+KEY3,FFFF31
7K4 Target Short AddressFFFFAT+KEY4,FFFF41
8K5 Target Short AddressFFFFAT+KEY5,FFFF51
9APP Password SwitchOffAT+TYPE0
10APP Connection Password1234AT+PIN1234
11Broadcast NameJDY-24MAT+NAMEJDY-24M

5.2. Serial Port AT Instruction Set

To configure the JDY-24M module, send AT commands via the serial port. Each AT command must be terminated with 'rn' (carriage return and newline).

SequenceInstructionFunctionDefault
1ATTest commands-
2AT+RESETReset module-
3AT+VERSIONQuery firmware version-
4AT+LADDRRead MAC address-
5AT+NAMERead and write broadcast nameJDY-24M
6AT+PINConnection password settings1234
7AT+TYPEWhether to open password connection method0
8AT+BAUDSet baud rate115200
9AT+DISCDisconnect-
10AT+STATRead connection status0
11AT+STARTENBoot sleep settings1
12AT+ADVINTSet broadcast interval1
13AT+POWRSet transmission power3
14AT+ROLESet operating mode0
15AT+SLEEPSleep instruction-
16AT+DEFAULTRestore factory configuration-
17AT+INQHost search slave broadcast-
18AT+STOPStop broadcasting-
19AT+CONNConnect to the scan list ID number-
20AT+CONAInstructions MAC address-
21AT+BANDBinding from machine MAC address-
22AT+CLRBANDClear binding-
23AT+SRBANDConnect the slave with the strongest peripheral signal-
24AT+MESHMESH - sends the data-
25AT+KEYKey parameters-
26AT+NETIDNetworking ID number of the configuration1189
27AT+MADDRNetworking short addressMAC address after two
28AT+MCLSSNetworking device type0 (router)
29AT+FRIENDAdd private friends MAC address000000000000
30AT+CLRFRIENDClear the private password friends-
31AT+FRTYPEFriend types0
32AT+IBUUIDiBeacon UUID that identifies the configuration-
33AT+MAJORiBeacon MAJOR configuration000A
34AT+MINORiBeacon MINOR configuration0007
35AT+IBSINGiBeacon SING configuration-
36AT+ENLOGSerial output status switch1 (on)

5.3. MESH Short Address Table (MADDR)

The MESH network uses short addresses for device identification and communication. A short address is equivalent to a device's ID number within the network.

AddressFunctionDescription
0XFFFFBroadcast AddressThe device short address cannot be configured as 0XFFFF. Broadcast data can be received by all devices in the network.
0X0002 to 0XFF00Unicast AddressDevice address. Users can set short addresses within this range. Unicast data can only be received by devices with specified addresses.
0X0001Machine Center AddressDesignated for the machine center.
0xFF01 to 0XFFFESystem AddressGenerally not recommended for user configuration.

6. User Tips

  • Always ensure the power supply voltage is within the specified range (1.9-3.6V) to prevent damage to the module.
  • When using AT commands, remember to append 'rn' (carriage return and newline) to each command for proper interpretation by the module.
  • For MESH networking, carefully plan your network ID (NETID) and short addresses (MADDR) to avoid conflicts and ensure reliable communication.
  • If experiencing connectivity issues, try resetting the module using the AT+RESET command or restoring factory defaults with AT+DEFAULT.
  • The PCB antenna is integrated; avoid obstructing it with metal enclosures or other components that could degrade signal strength.

7. Troubleshooting

  • Module not responding to AT commands:
    Check serial port connections (TXD/RXD swapped?), baud rate (default is 115200), and ensure commands are terminated with 'rn'. Verify power supply.
  • Cannot connect to the module:
    Ensure the module is powered on and advertising (check STAT pin if available). If using a password, ensure it's correct (default 1234). Check if the module is in the correct operating mode (AT+ROLE).
  • Poor signal strength or range:
    Ensure the PCB antenna is not obstructed. Test in an open environment. Check for sources of interference.
  • MESH network issues:
    Verify all modules have the same NETID. Ensure unique short addresses (MADDR) are assigned to each device. Check the networking device type (AT+MCLSS).
  • Unexpected behavior:
    Try restoring the module to factory default settings using the AT+DEFAULT command.

8. Maintenance

The JDY-24M module is a robust electronic component designed for long-term operation with minimal maintenance. Follow these guidelines:

  • Environmental Conditions: Keep the module in a dry environment, away from moisture, dust, and corrosive substances. Operate within the specified temperature range of -40 to 85 °C.
  • Cleaning: If cleaning is necessary, use a soft, dry cloth. Avoid using liquids or harsh chemicals.
  • Handling: Handle the module with care to avoid physical damage to the PCB or components. Electrostatic discharge (ESD) precautions should be observed during handling.
  • Firmware Updates: Check the manufacturer's website periodically for any available firmware updates that may improve performance or add new features.

9. Warranty and Support

For specific warranty information, please refer to the terms and conditions provided by your retailer or the manufacturer, SZYTF. Technical support may be available through the seller or manufacturer's official channels. Keep your purchase receipt for any warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.