PowMr HHJ-60A

Contents

PowMr 60A MPPT Solar Charge Controller User Manual

Model: HHJ-60A | Brand: PowMr

1. Overview

The PowMr HHJ-60A MPPT Solar Charge Controller is an advanced maximum power point tracking (MPPT) technology-based device designed for solar systems. It offers a charge controller conversion efficiency of up to 97%.

Key features include:

  • 100% MPPT technology for optimal power harvesting.
  • Built-in DSP controller with high performance.
  • Automatic battery voltage detection for 12V, 24V, 36V, and 48V battery banks.
  • Three-stage charging process to optimize battery performance.
  • Multi-function LCD display for monitoring system data and statuses.
  • Comprehensive protection features including reverse polarity protection for solar panels, overcharge protection, and over-temperature protection.
  • Suitable for various battery types: sealed lead acid, vented Gel, and Lithium batteries.
  • Easy to mount and install.

Note: The output terminal is designed for low-power loads (lamps only: 12V system less than 60W, 24V/36V/48V system less than 100W). Connecting to other loads may cause damage. The output for the battery does not have reverse polarity protection.

Video: Unboxing and initial overview of the PowMr HHJ-60A MPPT Solar Charge Controller, demonstrating its components and basic setup.

2. Important Safety Instructions

Please read all instructions and cautions carefully before installation and operation. This manual uses the following symbols to indicate potentially dangerous conditions or important safety information:

⚠ WARNING: Indicates a potentially dangerous condition. User extreme caution when performing this task.

CAUTION: Indicates a critical procedure for safe and proper operation of the controller.

NOTE: Indicates a procedure or function that is important to the safe and proper operation of the controller.

2.1. General Safety Information

  • Read all instructions and cautions in the manual before beginning installation.
  • There are no serviceable parts inside this controller. DO NOT disassemble or attempt to repair it.
  • DO NOT allow water to enter the controller.
  • Ensure all connections going into and from the controller are tight.

2.2. Charge Controller Safety

  • NEVER connect the solar panel array to the controller without a battery. The battery MUST be connected first.
  • Ensure input voltage does not exceed 190 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to ensure the voltage does not exceed this value when connecting panels together.

2.3. Battery Safety

  • Use only sealed lead-acid, flooded, gel, or lithium batteries which must be deep cycle.
  • Explosive battery gases may be present while charging. Ensure adequate ventilation to release gases.
  • Be careful when working with large lead-acid batteries. Wear eye protection and have fresh water available in case of contact with battery acid.
  • Carefully read battery manuals before operation.
  • DO NOT let the positive (+) and negative (-) terminals of the battery touch each other. Recycle batteries when replaced.
  • Over-charging and excessive gas precipitation can damage battery plates and activate material shedding. Too high or too long an equalizing charge may cause damage. Review specific requirements for the battery used.
  • Equalization is only for non-sealed/vented/flooded/wet cell lead-acid batteries.
  • DO NOT equalize VRLA type AGM/Gel/Lithium cell batteries UNLESS permitted by the battery manufacturer.

⚠ WARNING:
• Connect battery terminals to the charge controller BEFORE connecting the solar panel(s) to the charge controller. NEVER connect solar panels to the charge controller until the battery is connected.
• DO NOT connect any inverters or battery charger into the load terminal of the charge controller.
• Once equalization is active in battery charging, it will not exit this stage unless there is adequate charging current from the solar panel. There should be NO load on the batteries when in the equalization charging stage.

3. Setup & Installation

Follow these steps for proper installation:

3.1. Instruction Notes

  1. 1st step: Connect the batteries
    Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (marked with the battery symbol). If the system is 12V, ensure your battery voltage is more than 12V for the controller to boot up.
  2. 2nd step: Connect the solar panel
    Ensure that the PV modules are protected from incident light. Ensure the solar panel input does not exceed the maximum permissible input current. Connect the PV modules connection cable to the correct polarity of the left pair of terminals on the solar charge controller (marked with the PV modules symbol).
  3. 3rd step: Connect loads
    Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (marked with the lamp symbol). To avoid any voltage on the wires, connect the wire to the load before connecting to the controller.
  4. 4th step: Final work
    Tighten all cables connected to the controller and remove all debris around the controller, leaving a space of approximately 5.91 inches (15 cm) for ventilation.

Note: If the reading data of PV or battery is constantly changing, do not worry. The controller is finding the MPP point, which can be caused by insufficient PV input power or voltage. Contact our technical team for assistance if needed.

3.2. Air Circuit Breaker Installation

We strongly recommend connecting a fuse directly to the battery to protect against any short circuit at the battery wiring. Solar PV modules generate current when exposed to light. This current varies with light intensity, but even low light levels can produce full voltage. Protect solar modules from incident light during installation. Never touch uninsulated cable ends, use only insulated tools, and ensure the wire diameter is appropriate for the expected currents of the solar charge controller. Connections must always be made in the sequence described below.

Wiring diagram for PowMr MPPT Solar Charge Controller
Wiring diagram for the PowMr MPPT Solar Charge Controller, showing connections for solar panels, battery, and DC load. Always connect the battery bank first.

Reminder: It's better to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, it's the same way to connect wires.

  1. Install an air circuit breaker between the controller and batteries. Turn off the circuit breaker, then connect batteries to the controller with correct polarity.
  2. Install an air circuit breaker between the controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity is correct, then connect wires between PV modules and the controller.
  3. Turn on the air circuit breaker between the controller and batteries.
  4. Turn on the air circuit breaker between the controller and PV modules.
  5. The controller will enter self-test mode. Its LCD will display parameters if all connections are correct. The RUN lamp (under the fan inside the casing) will flash every one second. If the controller does not respond, please re-read the manual or contact support.

3.3. Air Circuit Breaker and Wires Requirement

ModelsCopper wiresAir circuit breakers
HHJ-60A6mm²x2PCS100A

4. Operation

4.1. LCD Display

The LCD provides real-time information about the system's status. The main interface shows PV voltage/output power, battery voltage/charging current, working mode/temperature, and fault codes. A sub-interface provides more detailed settings and readings.

Functional design, LCD, fan cooling
Detailed view of the controller's functional design, including the backlight LCD screen and fan cooling system. The LCD displays various parameters like battery charging, working mode, and production mode.
ItemDescription
1PV voltage / Output power
2Battery voltage / Charging current
3Working mode / Temperature
4Fault code

4.2. Working Mode

ModeDescription
3.0Night mode, no charging
4.0MPPT mode
7.0Absorption mode
8.0Floating mode

4.3. Manual Setting

Reminder: The controller will work fine under default settings except for lithium batteries.

CAUTION: All steps must be carried out when the PV modules are disconnected from the controller.

  1. Step 1: D00 (Load Working Time)
    Press the PRG button, then the LCD displays D00. This setting is for load working time (Default is 24-hour). Press ENT until numbers flash, then use UP/DOWN to set the desired time. Long-press ENT to confirm. The output voltage is the same as the battery. This load output is only for small DC loads less than 5A. If no load is connected, leave it.
  2. Step 2: D01 (Floating Charging Voltage)
    Press the UP button, the LCD shows 13.8 (default value). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.
  3. CAUTION: This value is for one 12V battery. If multiple batteries are in series, the controller will automatically multiply the voltage proportionally, and the LCD will only display the voltage of one battery (e.g., for a 4x12V battery bank, setting 14.1V will result in a 4x14.1V charge voltage, but the LCD will still display 14.1V).

  4. Step 3: D02 (Absorption Charging Voltage)
    Continue to press the UP button, the LCD shows 14.5 (highest absorption charging voltage). Follow the same procedure as D01 to set and confirm the voltage.
  5. Step 4: D03 (Battery Discharge Protection)
    Continue to press the UP button, the LCD shows 10.0. This is the protection value for battery discharge. Follow the same procedure as D01 to set and confirm the voltage. This means the output power from OU+ and OU- will be cut off when a 12V battery drops below 10.0V.
  6. Step 5: D04 (Battery Voltage Calibration)
    Continue to press the UP button, the LCD shows C12.2. This setting is used to calibrate the battery voltage, ensuring the controller's detected battery voltage matches the actual battery voltage.
  7. Step 6: D05 (Battery Type Setting)
    Continue to press the UP button, the LCD shows the battery type setting program. The default option is USE. The available battery types are:
    TypeDescription
    SELSealed Lead-Acid Battery
    GELGel Sealed Lead-Acid Battery
    FLdFlooded Lead-Acid Battery
    L044-series Lithium Iron Phosphate Battery
    L088-series Lithium Iron Phosphate Battery
    L1515-series Lithium Iron Phosphate Battery
    L1616-series Lithium Iron Phosphate Battery
    USEUser-defined Battery Type

    CAUTION: When selecting SEL, GEL, and FLd battery types, the controller automatically detects the system voltage.

  8. Step 7: D06 (User-defined System Voltage)
    If you choose the USE option in the D05 battery type setting, you will need to manually configure the system voltage in the D06 setup program. The configuration range is 12V/24V/36V/48V.

Press ESC to exit the setting menu.

Reminder: After setting all steps, please disconnect the battery. Reconnect the controller to verify successful settings. Once all settings are confirmed, connect the PV modules to the controller.

5. Troubleshooting & Protections

5.1. Troubleshooting Guide

CodeDescriptionHow to solve
18Input PV voltage is lowIncrease the PV voltage
60Over-temperature protectionFan will work and temperature reduction automatically
63Battery voltage is highBattery high voltage protection and wait for recovery
65Battery voltage is lowBattery over-discharge and wait for recovery
71Input PV voltage is highDecrease the PV voltage
73Over-charging currentDecrease the PV power

5.2. Protections

  1. PV Over Current: The controller will limit charging power to the rated charge power. An over-sized PV array will not operate at maximum power point.
  2. PV Short Circuit: When a PV short circuit occurs, the controller will stop charging. Remove the short circuit to resume normal operation.
  3. PV Reverse Polarity: Full protection against PV reverse polarity. No damage to the controller. Correct the connection to start normal operation.
  4. Battery Over Voltage: If other energy sources charge the battery, and the battery voltage exceeds 15.5V (for 12V system), 31.0V (for 24V system), 46.5V (for 36V system), or 62.0V (for 48V system), the controller will stop charging to protect the battery from overcharging damage. (Note: 'Stop charging' means the charging current becomes very low).
  5. Battery Over Discharge: When battery voltage drops to the set low voltage disconnect point, the controller will stop discharging to protect the battery from over-discharging damage.
  6. Load Over Current Protection: If the load current exceeds 1.25 times the maximum load current rating, the controller will disconnect the load.
  7. Load Short Circuit Protection: Once a load short circuit happens, the Load Short circuit protection will activate automatically.
  8. Over Temperature Protection: The controller includes mechanisms to protect against overheating.

6. Specifications

ParameterValue (HHJ-60A)
Model NameMPPT-60A
Charging modeMPPT Maximum power point tracking automatically
Charging3-stage: constant current (MPPT), constant voltage (Absorption Voltage), floating charge
System typeDC12V/24V/36V/48V Recognition automatically
System voltage automatic recognition12V system (DC9V-DC15V)
24V system (DC18V-DC29V)
36V system (DC30V-DC39V)
48V system (DC40V-DC60V)
Soft start time≤1S
Dynamic response and recovery time≥98.1% (Voc is 1.5 or 2 times than battery, then it’s best efficiency)
PV utilization≥99%
Input specification
Voc from PV (Make sure Voc of PV meets requirement. Voc is 1.5 or 2 times than battery for best efficiency.)12V system (DC20V~DC80V)
24V system (DC37V~DC105V)
36V system (DC50V~DC160V)
48V system (DC72V~DC160V)
The maximum PV input voltage (Voc)DC190V (Controller can’t work at this voltage for long duration, will break controller. Refer to Input voltage from PV.)
The maximum PV input power (Total power rated of PV can’t be over this watt that will break the controller.)12V (360W)
24V (720W)
36V (1080W)
48V (1440W)
12V (480W)
24V (960W)
36V (1400W)
48V (1700W)
12V (600W)
24V (1200W)
36V (1800W)
48V (2200W)
12V (720W)
24V (1440W)
36V (2100W)
48V (2800W)
Output specification
Selectable battery type (default is Sealed)Vented/Sealed/Gel/NiCd/Lithium battery (defined voltage for other battery by user)
Absorption Charging VoltageRefer to Batteries charging reference
Floating Charging VoltageRefer to Batteries charging reference
Overcharging protection voltage12V system (15V)
24V system (30V)
36V system (45V)
48V system (60V)
Rated output current30A40A50A60A
Temperature Coefficient±0.02%/centi-degree
Automatic temperature compensation14.2V-(Max temperature-25 centi-degree)*0.3
Output voltage ripple-peak100mV
Output voltage accuracy≤±1%
Input Anti-intrusion protectionYes
Temperature Protection75°C
Temperature increased protectionOutput power will reduce when it’s more than 70°C
Output power will be normal when it’s less than 55°C
Fan-on temperature>40°C
Fan-off temperature<35°C
Acoustic noise≤40dB
Cooling wayForced air cooling
ComponentsImported materials, Accord to EU standards, Industrial grade range.
Environmental requirementsMeet 2002/95/EC; No cadmium, hydrides and fluorides
Security LevelAccord to CE, PSE, FCC, EMC, EN60950
Electromagnetic compatibilityAccord to EN61000, EN55022, EN55024
EnclosureIP21
Environmental temperature-20°C ~ +55°C
Storage temperature-40°C ~ +75°C
Size (mm)/(in)214x115x50mm / 8.43x4.53x1.97in
Net weight (Kg)/(lb)1.1 / 2.43
Gross weight (Kg)/(lb)1.2 / 2.65
PowMr MPPT Solar Charge Controller dimensions and internal components
Image showing the dimensions (11.5cm x 21.4cm x 5cm) and internal components like capacitance and copper coil transformer, highlighting multi-function protection features.

7. Content Included

The product package typically includes:

  • 1x MPPT Solar Charge Controller (HHJ-60A)
  • 4x Corner connections
  • 4x Screws for controller casing
  • 1x User Manual (English)
PowMr MPPT Solar Charge Controller package contents
Image showing the PowMr MPPT Solar Charge Controller, its packaging box, user manual, and mounting accessories.

8. User Tips

No specific user tips were found in the provided reviews or Q&A content.

9. Warranty & Support

9.1. Warranty Regulations

Any damaged unit caused by the user's failure to install, disassemble, or incorrect use of this product may void the warranty.

  • Within 30 days from the date of purchase, a faulty controller will be replaced free of charge under normal use (with authorization from technical personnel).
  • Within 2 years from the date of purchase, a faulty controller will be repaired free of charge.

Note: Disassembling the product privately voids the warranty.

9.2. Liability Disclaimer

The manufacturer shall not be liable for damages, especially to the battery, caused by use other than as intended or as mentioned in this manual, or if the recommendations of the battery manufacturer are neglected. The manufacturer is not liable if service or repair has been carried out by any unauthorized person, or due to unusual use, wrong installation, or bad system design.

9.3. Contact Information

For support or inquiries, please use the following contact details:

  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.