1. Important Safety Instructions
WARNING: Indicates a potentially dangerous condition. Use extreme caution when performing this task.
CAUTION: Indicates a critical procedure for safe and proper operation of the controller.
NOTE: Indicates a procedure or function that is important to the safe and proper operation of the controller.
General Safety Information
- Read all instructions and cautions in the manual before beginning installation.
- There are no serviceable parts for this controller. DO NOT disassemble or attempt to repair.
- DO NOT allow water to enter the controller.
- Make sure all connections going into and from the controller are tight.
Charge Controller Safety
- NEVER connect the solar panel array to the controller without a battery. Battery must be connected first.
- Ensure input voltage does not exceed 190 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to make sure the voltage does not exceed this value when connecting panels together.
Battery Safety
- Use only sealed lead-acid, flooded, gel, or lithium batteries which must be deep cycle.
- Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases.
- Be careful when working with large lead-acid batteries. Wear eye protection and have fresh water available in case there is contact with battery acid.
- Carefully read battery manuals before operation.
- Do NOT let the positive (+) and negative (-) terminals of the battery touch each other.
- Recycle battery when it is replaced.
- Over-charging and excessive gas precipitation may damage battery plates and activate material shedding. Too high or too long an equalizing charge may cause damage. Review specific requirements of the battery used.
- Equalization is carried out only for non-sealed / vented / flooded / wet cell lead-acid batteries.
- Do NOT equalize VRLA type AGM / Gel / Lithium cell batteries UNLESS permitted by battery manufacturer.
WARNING:
- Connect battery terminals to the charge controller BEFORE connecting the solar panel(s) to the charge controller. NEVER connect solar panels to charge controller until the battery is connected.
- Do NOT connect any inverters or battery charger into the load terminal of the charge controller.
- Once equalization is active in battery charging, it will not exit this stage unless there is adequate charging current from the solar panel. There should be NO load on the batteries when in equalization charging stage.
2. Setup and Installation
The PowMr MPPT 60A Solar Charge Controller (Model HHJ-60A) is designed for efficient solar power management. It features 100% MPPT technology, a high-performance DSP controller, and automatic voltage detection for 12V/24V/36V/48V battery banks. It supports various battery types including sealed lead-acid, vented gel, and lithium batteries.
Video: Overview of the PowMr MPPT 60A Solar Charge Controller, highlighting its features and applications.
Dimensions
The controller measures 214mm x 115mm x 50mm (8.43in x 4.53in x 1.97in).

Image: Physical dimensions of the controller and a view of its internal components, including the copper coil transformer and capacitance.
Installation Steps
CAUTION: Use only the provided screws. Using other screws may damage the internal PCB. Apply proper torque to avoid damage.
- Connect the batteries: Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (marked with the battery symbol). If the system is 12V, ensure your battery voltage is above 12V for the controller to boot up.
- Connect the solar panel: Ensure the PV modules are protected from incident light. Do not exceed the maximum permissible input current. Connect the PV modules connection cable to the correct polarity of the left pair of terminals on the solar charge controller (marked with the PV modules symbol).
- Connect loads: Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (marked with the lamp symbol). To avoid voltage on the wires, connect the wire to the load before connecting to the controller.
- Final check: Tighten all cables connected to the controller and remove all debris around the controller, leaving a space of approximately 5.91 inches for ventilation.
NOTE: When the reading data of PV or battery is constantly changing, the controller is finding the Maximum Power Point (MPP). This is normal. If it persists, check your PV input power or voltage.
Air Circuit Breaker Installation
It is strongly recommended to connect a fuse directly to the battery to protect against short circuits at the battery wiring. Solar PV modules generate current whenever light strikes them. Protect solar modules from incident light during installation. Never touch uninsulated cable ends, use only insulated tools, and ensure the wire diameter is in accordance with expected currents.
Air Circuit Breaker and Wires Requirement
| Models | Copper wires | Air circuit breakers |
|---|---|---|
| HHJ-60A | 6mm²x2PCS | 100A |
Reminder: It’s better to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, it’s the same way to connect wires.

Image: Wiring diagram illustrating connections for solar panels, battery, and DC load to the MPPT solar charge controller. Also shows maximum PV input power for different system voltages.
Connection Sequence:
- Install air circuit breaker between controller and batteries. Turn off the circuit breaker, then connect batteries to controller with correct polarity.
- Install air circuit breaker between controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity is correct, then connect wires between PV modules and controller.
- Turn on the air circuit breaker between controller and batteries.
- Turn on the air circuit breaker between controller and PV modules.
- The controller goes into self-test mode. Its LCD displays parameters if all is correct. The RUN lamp (under the fan inside the casing) will flash every one second. If the controller is unresponsive, please read the full manual again or contact support.
3. Operating Instructions
LCD Display
The LCD screen provides real-time information about the system status. The main interface displays PV voltage/output power, battery voltage/charging current, working mode/temperature, and fault codes. Sub-interfaces show load timer, floating voltage, absorption voltage, battery type, calibration voltage, and under-voltage disconnection voltage.

Image: Detailed view of the controller's LCD screen, showing the main display and various sub-interface parameters like load timer, floating voltage, and battery type settings.
Working Modes
- 3.0 Night mode: No charging.
- 4.0 MPPT mode: Maximum Power Point Tracking.
- 7.0 Absorption mode: Battery charging stage.
- 8.0 Floating mode: Battery charging stage.
Manual Settings
Reminder: The controller will work fine under default settings except for lithium batteries.
CAUTION! All steps must be carried out when the PV modules are disconnected from the controller.
Step 1: D00 (Load Working Time)
Press the PRG button, then the LCD displays D00. This sets the load working time (default is 24-hour). Press ENT until numbers flash, then use UP/DOWN to set the desired time. Long-press ENT to confirm. The output voltage is the same as the battery. The load is only for small DC loads less than 5A current. If no load, leave it.
Step 2: D01 (Floating Charging Voltage)
Press the UP button, LCD shows 13.8 (default value). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.
CAUTION! This value is for one 12V battery. If there are multiple batteries in series, the controller will automatically multiply them in proportion. The LCD will only display the voltage of one battery (e.g., for a 4x12V battery, if you set 14.1V, the charge voltage will be 4x14.1V, but the LCD will only display 14.1V).
Step 3: D02 (Absorption Charging Voltage)
Continue to press the UP button, LCD shows 14.5 (highest absorption charging voltage). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.
Step 4: D03 (Battery Discharge Protection)
Continue to press the UP button, LCD shows 10.0 (protection value for battery discharge). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm. This means it’s protected when a 12V battery is less than 10.0V and there is no output power from OU+ and OU-.
Step 5: D04 (Battery Voltage Calibration)
Continue to press the UP button, LCD shows C12.2. This setting calibrates the battery voltage by adjusting the value, ensuring the controller's detected battery voltage matches the actual battery voltage.
Step 6: D05 (Battery Type Setting)
Continue to press the UP button, LCD shows the battery type setting program. The default option is USE. Available battery types:
| Battery Type | Description |
|---|---|
| SEL | Sealed Lead-Acid Battery |
| GEL | Gel Sealed Lead-Acid Battery |
| FLd | Flooded Lead-Acid Battery |
| L04 | 4-series Lithium Iron Phosphate Battery |
| L08 | 8-series Lithium Iron Phosphate Battery |
| L15 | 15-series Lithium Iron Phosphate Battery |
| L16 | 16-series Lithium Iron Phosphate Battery |
| USE | User-defined Battery Type |
CAUTION! When selecting SEL, GEL, and FLd battery types, the controller automatically detects the system voltage.
Step 7: D06 (System Voltage for User-defined Battery Type)
If you choose the USE option in D05, you will need to manually configure the system voltage in the D06 setup program. The configuration range is 12V/24V/36V/48V.
Press ESC to exit the setting menu.
Reminder: After setting all steps, disconnect the battery and then reconnect the controller to confirm settings. Once settings are successful, connect PV modules to the controller.
4. Maintenance
To ensure optimal performance and longevity of your PowMr MPPT 60A Solar Charge Controller, regular maintenance is recommended:
- Cleanliness: Keep the controller free from dust and debris. Ensure ventilation openings are clear to allow for proper airflow and cooling.
- Connections: Periodically check all wiring connections (PV, battery, load) to ensure they are tight and free from corrosion. Loose connections can lead to power loss or overheating.
- Battery Health: Monitor your battery's state of charge and overall health. Ensure proper ventilation around batteries, especially lead-acid types, to dissipate any gases produced during charging.
- Environmental Conditions: Ensure the controller is installed in a cool, dry, and well-ventilated area, away from direct sunlight, moisture, and flammable materials.
- Firmware Updates: Check the manufacturer's website periodically for any available firmware updates that might improve performance or address known issues.
5. Troubleshooting and Protections
The controller includes multi-function protection features to ensure safe operation and easy troubleshooting.

Image: Icons representing various protection features: Load short circuit, Battery over discharge, Battery reverse polarity, PV short circuit, PV over current alarm, Battery overcharge, Controller overheating, and Load overload protection.
Troubleshooting Guide
| Code | Description | How to solve |
|---|---|---|
| 18 | Input PV voltage is low | Increase the PV voltage |
| 60 | Over-temperature protection | Fan will work and temperature reduction automatically |
| 63 | Battery voltage is high | Battery high voltage protection and wait for recovery |
| 65 | Battery voltage is low | Battery over-discharge and wait for recovery |
| 71 | Input PV voltage is high | Decrease the PV voltage |
| 73 | Over-charging current | Decrease the PV power |
Protections
- PV Over Current: The controller will limit charging power to its rated charge power. An over-sized PV array will not operate at maximum power point.
- PV Short Circuit: When a PV short circuit occurs, the controller will stop charging. Remove the short circuit to resume normal operation.
- PV Reverse Polarity: Full protection against PV reverse polarity, causing no damage to the controller. Correct the connection to start normal operation.
- Battery Over Voltage: If other energy sources charge the battery, and the battery voltage exceeds 15.5V (for 12V system), 31.0V (for 24V system), 46.5V (for 36V system), or 62.0V (for 48V system), the controller will stop charging to protect the battery from overcharging damage. (Note: "stop charging" means charging current becomes very low).
- Battery Over Discharge: When battery voltage drops to the set low voltage disconnect point, the controller will stop discharging to protect the battery from over-discharging damage.
- Load Over Current Protection: If the load current exceeds 1.25 times the maximum load current rating, the controller will disconnect the load.
- Load Short Circuit Protection: Once a load short circuit happens, the load short circuit protection will activate automatically.
- Over Temperature Protection: The controller will reduce output power if its internal temperature exceeds 70°C and resume normal operation when it drops below 55°C. The fan will activate if the temperature exceeds 40°C and turn off below 35°C.
6. Specifications
| Feature | Specification |
|---|---|
| Model No. | HHJ-60A Board Set |
| Charging mode | 3-stage (MPPT, Absorption, Floating) |
| System type | DC12V/24V/36V/48V Recognition automatically |
| 12V System Voltage Recognition | DC9V~DC15V |
| 24V System Voltage Recognition | DC18V~DC29V |
| 36V System Voltage Recognition | DC30V~DC39V |
| 48V System Voltage Recognition | DC40V~DC60V |
| Soft start time | ≤1S |
| Dynamic response and recovery time | 100us |
| Max efficiency | ≥98.1% (Voc is 1.5 or 2 times than battery for best efficiency) |
| PV utilization | ≥99% |
| 12V System Voc from PV | DC20V~DC80V |
| 24V System Voc from PV | DC37V~DC105V |
| 36V System Voc from PV | DC50V~DC160V |
| 48V System Voc from PV | DC72V~DC160V |
| Maximum PV input voltage (Voc) | DC190V (Controller cannot work at this voltage for long duration) |
| 12V System Max. PV Input Power | 720W |
| 24V System Max. PV Input Power | 1440W |
| 36V System Max. PV Input Power | 2100W |
| 48V System Max. PV Input Power | 2800W |
| Overcharging protection voltage | 60V |
| Limited current protection | 61A |
| Rated output current | 60A |
| Temperature Coefficient | ±0.02%/ centi-degree |
| Automatic temperature compensation | 14.2V-(Max temperature-25 centi-degree)*0.3 |
| Output voltage ripple-peak | 100mV |
| Output voltage accuracy | ≤±1% |
| Input Anti-intrusion protection | Yes |
| Temperature Protection | 75℃ / 167℉ |
| Fan-on temperature | >45℃ / 104℉ |
| Fan-off temperature | <35℃ / 95℉ |
| Acoustic noise | ≤40dB |
| Cooling way | Forced air cooling |
| Components | Imported materials, Accord to EU standards, Industrial grade range. |
| Environmental requirements | Meet 2002/95/EC; No cadmium, hydrides and fluorides |
| Security Level | Accord to CE, PSE, FCC, EMC, EN60950 |
| Electromagnetic Compatibility | Accord to EN61000, EN55022, EN55024 |
| Enclosure | IP21 |
| Size (mm)/(in) | 214x115x50mm/ 8.43x4.53x1.97in |
| Net weight(Kg)/(Ib) | 1.1/2.43 |
| Gross weight(Kg)/(Ib) | 1.2/2.65 |
| Environmental temperature | -20℃ ~ +55℃ |
| Storage temperature | -40℃ ~ +75℃ |
7. User Tips
- Proper Sizing: Ensure your solar panel array and battery bank are correctly sized for the controller's specifications to maximize efficiency and prevent damage.
- Ventilation: Always ensure adequate ventilation around the controller and batteries to prevent overheating and gas buildup.
- Battery Type Selection: Accurately select your battery type in the settings (D05) for optimal charging and battery longevity. For lithium batteries, manual voltage configuration (D06) is crucial.
- Initial Setup: Follow the connection sequence strictly: Battery first, then PV. Disconnect PV before making any changes to battery settings.
- Monitoring: Regularly check the LCD display for system status and any fault codes to address issues promptly.
8. Warranty and Support
Warranty Regulations
According to the prescription, any damaged unit caused by the user's failure to install, disassemble, or incorrect use of this product may provide maintenance.
- Within 30 days from the date of purchase, a faulty controller will be replaced free of charge under normal use (with authorized technical personnel).
- Within 2 years from the date of purchase, a faulty controller will be repaired free of charge.
Notes: Disassembled privately, no warranty.
Liability Disclaimer
The manufacturer shall not be liable for damages, especially to the battery, caused by use other than as intended or as mentioned in this manual, or if the recommendations of the battery manufacturer are neglected. The manufacturer shall not be liable if service or repair has been carried out by any unauthorized person, due to unusual use, wrong installation, or bad system design.
Content Included
- 1x MPPT Solar Charge Controller
- 4x Corner connections
- 4x Screws for controller casing
- 1x English manual
Contact Information
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Add: Henggang Street, Longgang District, Shenzhen, Guangdong, China
PDF User Manual: For a detailed user manual, please refer to the official PDF document available at PowMr MPPT Solar Charge Controller User Manual (PDF).