1. Introduction
The A-BF RX-350 is a cost-effective thermal imager designed for a wide range of applications. It features a 160x120 infrared resolution, a broad temperature measurement range, and PC software analysis capabilities. This device is an ideal tool for electricians, maintenance technicians, and professionals in various fields to quickly identify problem areas by visualizing temperature differences.
Applications include:
- Electronic device detection
- Mechanical overhaul
- Research on architectural defects
- Motor fault detection
- Detection of floor heating equipment
- Distribution box detection

2. Specifications
| Feature | Specification |
|---|---|
| Brand Name | A-BF |
| Model Number | RX-350 |
| Certification | CE, FCC |
| Infrared Resolution | 160x120 Pixels |
| Infrared Response Band | 8 to 14μm |
| Pixel Size | 12um |
| NETD | ≤50mK@25C.@F/1.1 |
| Lens Focal Length | 3.2mm |
| IFOV | 3.75mrad |
| Field of View | 35°x27° |
| Focus Mode | Focus-free |
| Temperature Measurement Range | -20℃ to +550℃ (-4F to 1022F) |
| Temperature Measurement Accuracy | ±2℃ (35.6F) or ±2% |
| Temperature Measurement Resolution | 0.1℃ |
| Temperature Measurement Mode | Center point/hot and cold spot tracking |
| Color Palette | Rainbow/iron red/cold color/white hot/black hot |
| Emissivity Setting | 0.01 to 1.00 adjustable |
| Thermal Imaging Frame Rate | <25Hz |
| Visible Light Resolution | 640x480 |
| Display Screen Size | 2.8 inches (240x320) |
| Image Display Mode | Infrared/visible light/dual light fusion |
| Lighting System | LED fill light |
| Built-in Storage | 4G eMMC (approx. 3G user available) |
| Storage Image/Video Format | JPG/MP4 |
| Image/Video Export Method | USB connection to computer |
| Image Analysis Function | PC offline analysis support |
| Menu Languages | Chinese, English, German, Italian |
| Battery Type | Removable rechargeable lithium battery (18650) |
| Battery Capacity | 2200mAh |
| Working Time | 2 to 3 hours |
| Power Interface | Micro USB |
| Automatic Shutdown | Configurable (5 min/20 min/none) |
| Operating Temperature | -10℃ to +50℃ |
| Storage Temperature | -20℃ to +60℃ |
| Relative Humidity | 10% to 85%RH (non-condensing) |
| Product Weight | 389g |
| Product Size | 96mm x 72mm x 22mm (approximate) |
3. Package Contents
Upon opening the package, please verify that all the following items are included:
- A-BF RX-350 Thermal Imager
- Carrying Case
- User Manual
- Power Adapter / Charging Cable

4. Device Overview
Familiarize yourself with the main components and screen elements of your RX-350 thermal imager.

Screen Elements Explanation:
- Emissivity (e=0.95 shown)
- Battery level
- The highest temperature cursor
- The lowest temperature cursor
- Color code
- Time
- Date
- Central temperature
- Central point temperature cursor
Controls:
- MENU Button: Accesses the main menu.
- SELECT/ENTER Button: Confirms selections or enters sub-menus.
- Directional Buttons (Up, Down, Left, Right): Navigate through menus and adjust settings.
5. Setup
5.1 Charging the Battery
The RX-350 uses a removable 18650 rechargeable lithium battery. Before first use, ensure the battery is fully charged. Connect the device to a power source using the provided Micro USB cable and power adapter. The battery indicator on the screen will show charging status.
5.2 Powering On/Off
Press and hold the power button (usually located on the handle or side) to turn the device on or off. The device has configurable automatic shutdown settings (5 minutes, 20 minutes, or none) to conserve battery life.
5.3 Language Selection
Navigate to the 'Settings' menu using the MENU button and directional controls. Select 'Language' to choose your preferred interface language from Chinese, English, German, or Italian.
6. Operating Instructions
6.1 Basic Operation
Once powered on, the device will display a thermal image. Use the directional buttons to navigate through menus and adjust settings. The SELECT/ENTER button confirms your choices.
6.2 Temperature Measurement
The RX-350 provides real-time temperature readings. It supports center point measurement, as well as hot and cold spot tracking, which automatically highlights the highest and lowest temperatures within the field of view.

6.3 Emissivity Setting
Emissivity (ε) is a crucial setting for accurate temperature measurement. It can be adjusted from 0.01 to 1.00. Different materials have different emissivities. Refer to standard emissivity tables for common materials or adjust as needed for specific surfaces, especially those with reflective properties.
6.4 Color Palettes
The device offers several color palettes to visualize temperature differences. You can select from: Rainbow, Iron Red, Cold Color, White Hot, and Black Hot. Each palette emphasizes different aspects of the thermal image, making certain temperature variations more apparent.

6.5 Image Display Modes
The RX-350 supports multiple display modes:
- Infrared: Displays only the thermal image.
- Visible Light: Displays a standard visual image (from the built-in visible light camera).
- Dual Light Fusion: Overlays the thermal image onto the visible light image, providing context for the temperature data.

6.6 Photo and Video Capture
The device supports capturing images (JPG format) and videos (MP4 format). Use the dedicated photo/video button or menu option to record. All captured media is stored on the internal 4G eMMC storage.
6.7 PC Software Analysis
For detailed analysis, connect the RX-350 to a computer via the Micro USB cable. The device will appear as a mass storage device, allowing you to export stored images and videos. Dedicated PC software is available for offline analysis of the thermal data, providing advanced reporting and measurement capabilities.

7. Maintenance
7.1 Battery Care
To prolong battery life, avoid fully discharging the battery frequently. Recharge the battery regularly, especially if the device will be stored for an extended period. Store the device with a partially charged battery (around 50%).
7.2 Cleaning the Device
Use a soft, dry cloth to clean the exterior of the thermal imager. For the lens, use a lens cleaning cloth and specialized lens cleaning solution to avoid scratches. Do not use abrasive cleaners or solvents.
7.3 Storage
Store the device in its protective carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature is -20℃ to +60℃.
8. Troubleshooting
8.1 Device Not Powering On
- Ensure the battery is sufficiently charged. Connect the device to a charger and wait for a few minutes before attempting to power on again.
- Verify the battery is correctly inserted.
8.2 Inaccurate Temperature Readings
- Check and adjust the emissivity setting for the material being measured. Incorrect emissivity is a common cause of inaccurate readings.
- Ensure the target is within the optimal measurement distance.
- Clean the lens if it is dirty or smudged.
8.3 Device Not Detecting Gas Leaks
The A-BF RX-350 is a thermal imager designed for temperature detection and visualization. It is not equipped to detect gas leaks, including ammonia gas. For gas leak detection, specialized gas detectors are required.
9. User Tips
- Emissivity Adjustment: Always adjust the radiation coefficient (emissivity) to match the object's surface for increased measurement accuracy, especially for objects with reflective surfaces.
- Hot/Cold Spot Tracking: Utilize the highest and lowest temperature cursors to quickly identify critical temperature points within the thermal image.
- Color Palette Selection: Experiment with different color palettes to find the one that best highlights the temperature variations relevant to your inspection task.
- PC Software: For in-depth analysis and professional reporting, make use of the PC offline analysis software.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official A-BF website. Keep your proof of purchase for warranty claims.