1. Introduction
This manual provides essential information for the safe and effective use of Cooper BS88:4 series slow melt fuses. These fuses are designed to protect electrical circuits from overcurrent conditions, preventing damage to equipment and ensuring safety. Please read this manual thoroughly before installation and operation.
2. Product Overview
The Cooper BS88:4 series slow melt fuses are high-quality protective devices suitable for various industrial and commercial applications. They are designed to withstand temporary overcurrents without blowing, making them ideal for circuits with high inrush currents, such as those found in motor starting applications. Each fuse is rated for 690V AC and is available in multiple amperage ratings from 25A to 80A.

Figure 2.1: Cooper 25ET 25A BS88:4 Slow Melt Fuse

Figure 2.2: Various Cooper BS88:4 Slow Melt Fuses
3. Safety Information
WARNING: Electrical work should only be performed by qualified personnel. Failure to follow these safety guidelines may result in electric shock, fire, or serious injury.
- Always disconnect power to the circuit before installing, inspecting, or replacing fuses.
- Ensure the replacement fuse has the correct voltage and amperage rating for the circuit. Using an incorrect fuse can lead to inadequate protection or circuit damage.
- Do not bypass or tamper with fuses.
- Wear appropriate personal protective equipment (PPE), including insulated gloves and safety glasses, when working with electrical circuits.
- Never touch live electrical components.
- Ensure the fuse holder is compatible with the BS88:4 fuse type.
4. Installation
Installation of these fuses should be carried out by a certified electrician or qualified technician in accordance with local electrical codes and regulations.
- Power Disconnection: Before beginning any work, ensure that the main power supply to the circuit is completely disconnected and locked out to prevent accidental re-energization.
- Identify Fuse Holder: Locate the appropriate fuse holder for the circuit requiring protection.
- Verify Ratings: Confirm that the new Cooper BS88:4 fuse matches the required voltage (690V) and amperage rating (e.g., 25A, 32A, 63A, 80A) for the specific application.
- Insert Fuse: Carefully insert the fuse into the fuse holder, ensuring it is seated firmly and correctly.
- Secure Connections: If applicable, ensure any terminal connections to the fuse holder are tight and secure.
- Restore Power: Once the fuse is correctly installed and all connections are secure, restore power to the circuit.

Figure 4.1: Cooper 63ET 63A BS88:4 Fuse, showing terminals
5. Operation
Cooper BS88:4 slow melt fuses are passive protective devices. When installed correctly, they continuously monitor the current flowing through the circuit. Under normal operating conditions, the fuse allows current to pass unimpeded. In the event of an overcurrent or short circuit, the fuse element will melt, interrupting the circuit and protecting downstream equipment from damage. The "slow melt" characteristic means it can tolerate temporary, harmless overloads (like motor start-up currents) without blowing, but will open quickly on sustained or severe overcurrents.
6. Maintenance
These fuses are generally maintenance-free. However, periodic inspection of the fuse and its holder is recommended as part of a regular electrical system maintenance schedule.
- Visual Inspection: Check for any signs of physical damage, discoloration, or loose connections on the fuse and its holder.
- Replacement: If a fuse has blown, it must be replaced with a new fuse of the exact same type, voltage, and amperage rating. Do not attempt to repair a blown fuse.
- Environmental Conditions: Ensure the operating environment remains within specified temperature and humidity ranges to prevent premature fuse degradation.
7. Troubleshooting
The primary function of a fuse is to blow when an overcurrent condition occurs. If a fuse blows, it indicates a problem within the electrical circuit it is protecting.
- Repeated Blowing: If a fuse blows repeatedly after replacement, it is a strong indication of a persistent fault in the circuit, such as a short circuit, ground fault, or sustained overload. Do not continue to replace the fuse without investigating and resolving the underlying issue.
- No Power: If a circuit loses power, check the fuse. A blown fuse will typically show a visible break in the element or a discoloration.
- Consult a Professional: For any persistent issues or if you are unsure about the cause of a blown fuse, consult a qualified electrician.
8. User Tips
- Amperage Matching: Always ensure the replacement fuse's amperage rating precisely matches the original fuse or the circuit's design requirements. Using a fuse with a higher amperage rating can lead to inadequate protection and potential equipment damage or fire hazards.
- Application Specifics: Slow melt fuses are particularly useful for inductive loads (like motors) that have a high initial current draw but settle to a lower operating current. Ensure this fuse type is appropriate for your specific application.
9. Specifications
| Feature | Specification |
|---|---|
| Fuse Type | Slow Melt (Time-Delay) |
| Standard | BS88:4 |
| Voltage Rating | 690V AC |
| Amperage Ratings Available | 25A (25ET), 32A (32ET), 35A (35ET), 40A (40ET), 45A (45ET), 56A (56ET), 63A (63ET), 80A (80ET) |
| Manufacturer | Cooper |
| Origin of Manufacture | India (as per product markings) |
| Package Dimensions (approx.) | 15 cm (L) x 8 cm (W) x 5 cm (H) |
| Package Weight (approx.) | 0.021 kg |

Figure 9.1: Cooper 80ET 80A BS88:4 Fuse, showing voltage and amperage
10. Warranty and Support
For warranty information and technical support, please refer to the manufacturer's official documentation or contact Cooper directly. Contact details found on product packaging include:
- Manufacturer: Cooper (U.K.) Limited
- Address: Burton on the Wolds, Leicestershire, LE12 5TH, Made in India
- Telephone: +44 (0) 1509 882600
- Fax: +44 (0) 1509 882786
Always ensure you have the specific model and amperage details of your fuse when contacting support.