1. Safety Information
WARNING: Improper use of this meter can cause electric shock or damage to the instrument. Always follow standard safety procedures and the safety measures outlined in this manual.
- Before use, inspect the meter and test leads for any damage. Do not use if they appear broken or compromised.
- Ensure the correct input terminals, function, and range are selected for each measurement.
- Do not exceed the input limit values specified for each range to prevent damage to the meter.
- Exercise extreme caution when working around bare conductors or busbars.
- Do not use the meter in environments with explosive gases, vapors, or dust.
- When the measured voltage exceeds 60V DC or 30V AC RMS, proceed with caution to prevent electric shock.
- When using test leads, keep your fingers behind the guard rings.
- The meter complies with IEC-61010, GB/T13978-92, and GB4793.1-1995 safety standards, rated for CAT III 600V.
Safety Symbols
- ⚠ Warning: Important safety sign. Refer to the instruction manual before use. Incorrect use may lead to damage.
- 🔋 AC (Alternating Current)
- −–– DC (Direct Current)
- ⊕− AC or DC
- ⊥ Ground
- ⓒ CE: Conforms to European Union directives.
2. Product Overview
The Mastfuyi Digital Clamp Meter is a versatile tool designed for electricians and DIY enthusiasts, offering a wide range of measurement capabilities including AC/DC voltage, AC/DC current, resistance, capacitance, frequency, and temperature. It features a large digital display and intelligent overload protection.
Product Components and Functions

- Clamp Head: AC/DC current transformer.
- Head Trigger: Press to open the clamp head, release to close.
- LCD Display: Shows measurement readings and indicators.
- Power On Button: Turns the meter on/off.
- Function Switching and Flashlight Key: Short press to cycle through functions (NCV, LIVE, Capacitance, Diode, Temperature). Long press to turn the flashlight on/off.
- Data Lock Key (HOLD): Short press to lock the current display reading; short press again to unlock.
- Common Ground Input.
- Positive Input.
- Lighting (Flashlight).
- NCV Non-Contact Electric Field Measurement.
Note:
- The FY372 model features a dual-chip design for simultaneous measurement of voltage and current.
- FY372 and FY375 models feature a large screen capable of displaying two types of data simultaneously.
3. Setup
3.1 Battery Installation
The meter requires two 1.5V AAA batteries (included). To install or replace batteries:
- Ensure the meter is powered off and all test leads are disconnected.
- Locate the battery compartment on the back of the meter.
- Use a screwdriver to loosen the screw securing the battery cover.
- Remove the battery cover.
- Insert two new 1.5V AAA batteries, observing the correct polarity (+/-).
- Replace the battery cover and tighten the screw.
WARNING: Replace batteries immediately when the low battery indicator appears on the display to avoid inaccurate readings or potential safety hazards.
3.2 Connecting Test Leads
For measurements requiring test leads (e.g., voltage, resistance, capacitance, diode, temperature), insert the red test lead into the positive input terminal (8) and the black test lead into the common ground input terminal (7).
4. Operating Instructions
4.1 General Operation
- Power On: Short press the power button (4) to turn on the meter. The meter will enter auto-ranging mode, automatically identifying AC/DC voltage, resistance, continuity, and frequency functions.
- Function Selection: Short press the function switching key (5) to cycle through NCV, LIVE, Capacitance, Diode, and Temperature measurement modes.
- Flashlight: Long press the function switching key (5) to turn the built-in flashlight on or off.
- Data Hold: Short press the HOLD key (6) to freeze the current reading on the display. Press again to release.
4.2 Measurement Modes
The meter supports various measurement modes. Refer to the '12 Measurement Modes' image for visual guidance.

4.2.1 AC/DC Current Measurement
Supported by FY375 (AC/DC) and FY372/FY371 (AC only). The clamp jaw opening is 25mm.

Important:
- When measuring current, ensure the conductor is placed in the center of the clamp head to minimize measurement error.
- The meter can only measure one current-carrying conductor at a time. Measuring two or more conductors simultaneously will result in incorrect readings.
4.2.2 AC/DC Voltage Measurement
The meter automatically identifies AC or DC voltage. For AC voltage, the frequency will also be displayed.
Video: Demonstration of various measurement functions including AC/DC current, NCV, Live Wire Check, AC/DC voltage, Resistance, Continuity, Capacitance, Diode, and Temperature.
4.2.3 Resistance Measurement
Connect the test leads to the component to measure its resistance.
4.2.4 Capacitance Measurement
Supported by FY375 (up to 60mF) and FY372 (up to 1mF).

4.2.5 Frequency Measurement
The meter can measure frequencies up to 1000Hz.
4.2.6 Continuity Test
A built-in buzzer will sound if the measured resistance is less than 30Ω, indicating continuity.
4.2.7 Diode Test
Displays the approximate forward voltage drop of a diode.
4.2.8 NCV (Non-Contact Voltage) Detection
The NCV function detects alternating current voltage without direct contact. It displays an analog bar strength and emits sounds of varying frequencies based on the proximity to the power source.

4.2.9 Live Wire Mode
When testing a live wire, the display will show 'LIVE' and an alarm will sound. There will be no reaction for a neutral wire.

4.2.10 Temperature Measurement
Supported by FY375 and FY372 models, with a range of -20°C to 1000°C (-4°F to 1832°F).

5. Maintenance
This section provides basic maintenance information, including battery replacement instructions. Do not attempt to repair this meter unless you are an experienced service technician with relevant calibration, performance testing, and repair documentation.
5.1 General Maintenance
- To avoid electric shock or damage to the meter, do not allow moisture inside the meter.
- Before opening the casing or battery cover, ensure all test leads and input signal connections are removed.
- Regularly clean the meter casing with a damp cloth and a small amount of mild detergent. Do not use abrasive cleaners or chemical solvents.
- Dirty or wet input jacks can affect readings. To clean:
- Turn off the meter and remove all test leads from the input jacks.
- Remove any visible dirt from the jacks.
- Use a new cotton swab with a cleaning agent or lubricant to clean each jack. Lubricants can help prevent moisture-related contamination.
5.2 Battery Replacement
WARNING: To avoid incorrect readings that could lead to electric shock or personal injury, replace the batteries immediately when the 🔋 symbol appears on the display.
Follow the steps in Section 3.1 for battery replacement.
6. Troubleshooting
- No Display/Meter Not Turning On: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- Unstable Readings: Ensure the meter is not being used near strong electromagnetic interference. Check test lead connections for cleanliness and secure fit.
- 'OL' on Display: This indicates an over-range condition. Select a higher range or ensure the measured value is within the meter's capabilities.
- Low Battery Indicator: The 🔋 symbol indicates low battery. Replace the two 1.5V AAA batteries as described in Section 3.1.
- No Continuity Buzzer: Ensure the resistance being measured is below 30Ω. Check test leads for proper connection and integrity.
- Inaccurate Current Measurement: Ensure only one current-carrying conductor is placed within the clamp jaw and it is centered.
7. Specifications
General Specifications
- Max Display: 9999 Counts (FY375/FY372), 5999 Counts (FY371)
- Display Type: Analog and Digital
- Power: 2 x 1.5V AAA Battery
- Auto Power Off: After 14 minutes of no signal input.
- Low Battery Indication: Yes
- Polarity Display: Automatic '-' symbol for negative polarity.
- Overrange Display: 'OL' on LCD.
- Conversion Rate: Approximately 3 times/second.
- Operating Environment: 0-40°C (32-104°F), <80% RH (not considered below 10°C).
- Storage Environment: -10-50°C (14-122°F), <70% RH (remove battery).
- Altitude: <2000m.
- Max Voltage to Ground: 600V DC or 600V AC RMS.
- Dimensions: 177 x 66 x 30mm.
- Weight: Approximately 138g (without battery).
- Certifications: CE, FCC, RoHS.
- Standard: JBT9285-1999.
Measurement Range and Accuracy

| Feature | FY375 | FY372 | FY371 |
|---|---|---|---|
| AC Voltage | 600V | 600V | 600V |
| DC Voltage | 600V | 600V | 600V |
| AC Current | 200A | 200A | 200A |
| DC Current | 200A | No | No |
| Resistance | 60MΩ | 10MΩ | 10MΩ |
| Frequency | 1000Hz | 1000Hz | 1000Hz |
| Max Display | 9999 Counts | 9999 Counts | 5999 Counts |
| Capacitance | 60mF | 1mF | No |
| Temperature | -20°C~1000°C | -20°C~1000°C | No |
| Diode | Yes | Yes | Yes |
| Continuity | Yes | Yes | Yes |
| NCV | Yes | Yes | Yes |
| Live wire mode | Yes | Yes | Yes |
| Data hold | Yes | Yes | Yes |
| Zero calibration | Yes | No | No |
| True RMS | Yes | Yes | No |
| Auto range | Yes | Yes | Yes |
8. User Tips
- Start with Auto-Ranging: For unknown values, especially voltage or resistance, always start with the auto-ranging feature (if available on your model) to prevent damage to the meter or circuit.
- Correct Lead Placement: Double-check that your test leads are inserted into the correct input jacks for the measurement you intend to perform. Incorrect placement can lead to false readings or damage.
- NCV for Initial Safety: Before touching any wires, use the NCV function to quickly check for the presence of voltage. This is a crucial safety step.
- One Conductor for Current: Remember that clamp meters measure current by detecting the magnetic field around a single conductor. Never clamp around multiple wires simultaneously for current measurement.
- Keep it Clean: Regularly wipe down your meter and clean the test lead jacks to ensure optimal performance and longevity.
9. Warranty and Support
Warranty
This meter is guaranteed for one year from the date of manufacture against defects in materials and workmanship. This warranty does not cover damage caused by misuse, neglect, accident, unauthorized repair, or normal wear and tear.
Contact Information
For technical support, warranty claims, or service inquiries, please contact:
Huizhou Fuyi Electronic Technology Co., Ltd.Address: 5th Building, 4-5th Floor, Yinghui Electronic Technology Park, Dongsheng North Road No. 6, Chenjiang Street, Zhongkai High-tech Zone, Huizhou City
Sales Phone: 0752-2608993
Email: fuyikeji@1
Website: http://www.fuyikeji.com.cn/
10. Package Contents
The package for your Mastfuyi Digital Clamp Meter includes the following items:
- User Manual (1)
- Test Leads (1 set)
- 1.5V AAA Batteries (2)
- Warranty Card (1)
- Cloth Bag (1)
- K-type Temperature Probe (For FY375 and FY372 models only)
Note on User Manual Languages:
- FY375: User manuals in English, German, French, Spanish, Italian.
- FY372: English-language user manual.
- FY371: English-language user manual.


