This manual provides detailed instructions for the safe and efficient operation of your MYAMi Programmable DC Power Supply. This versatile device is engineered for precision and stability, making it ideal for a wide range of applications including laboratory experiments, mobile device repair, and general electronics work. It features precise voltage and current regulation, multiple protection functions, and programmable settings for enhanced usability.


Key Features
- Adjustable Voltage and Current: Precise control over output parameters for various testing needs.
- Power Display: Real-time display of output power for immediate feedback.
- Output Switch Control: Unique front-output on-off one-key switch for convenient operation.
- Parameter Storage: Three groups of preset parameters (M1, M2, M3) for quick recall of frequently used settings.
- Low Noise and Ripple: Designed for stable and clean power delivery, crucial for sensitive electronics.
- Digital Control: Coding switch for convenient, stable, and durable digital control.
- Multiple Protection Functions: Includes Over Voltage Protection (OVP) and Over Current Protection (OCP) to safeguard your device and connected circuits.
- Programmable Setting: Supports Modbus communication protocol for advanced control and automation.
- USB Fast Charging Interface: Integrated USB port for quick charging of compatible devices.
- Anti-collision LOCK Function: Prevents accidental changes to settings during operation.

Product Overview
Familiarize yourself with the components and controls of your power supply for optimal use.
Front Panel Controls and Indicators:

- Voltage Value Display: Shows the current output voltage.
- Current Value Display: Shows the current output current.
- Power Value Display: Shows the current output power.
- OCP Setting Button: Activates/deactivates Over Current Protection.
- OVP Setting Button: Activates/deactivates Over Voltage Protection.
- M1-M3 Buttons: Used to save and recall preset parameter values.
- ON/OFF Button: Controls the output power (turns output on/off).
- USB Charge Port: Provides a USB output for charging devices.
- C.V (Constant Voltage) Mode Indicator: Illuminates when the unit is operating in constant voltage mode.
- C.C (Constant Current) Mode Indicator: Illuminates when the unit is operating in constant current mode.
- Locked State Indicator: Illuminates when the control buttons are locked.
- Adjustment Knob: Rotary encoder for adjusting voltage and current values.
- Voltage Regulation Button: Press to select and set the voltage value.
- Current Regulation Button: Press to select and set the current value.
- Positive Output Terminal (RED +): Connect positive lead of load here.
Rear Panel Components:

- Negative Output Terminal (BLACK -): Connect negative lead of load here.
- Power On/Off Switch: Main power switch for the unit.
- Cooling Fan: Provides necessary ventilation to prevent overheating.
- AC Input (110V ±10% 50Hz/60Hz): Power input port.
- Fuse Box: Contains the protective fuse for the unit.
- Communication Port (RS232/RS485/USB): For programmable control and data communication.
Setup
- Initial Connection: Ensure the DC power supply is in the fully OFF state using the rear power switch (17) before connecting any wires to the output terminals.
- Secure Connections: Always double-check that all wire connections, especially to the positive (15) and negative (16) output terminals, are secure and properly seated before powering on the unit.
- Grounding: For safety, ensure the power supply is connected to an earth-grounded power outlet. The ground wire of your AC input cable must be properly connected to earth ground.
- Ventilation: Operate the product in a well-ventilated environment. Maintain at least 10 cm (approximately 4 inches) of clear space around the unit from other objects to ensure proper airflow for the cooling fan (18).
- Environmental Conditions: Avoid operating the device in environments with excessive dust, moisture, corrosive gases, or harmful substances.
- Warm-up: For optimal accuracy and stable performance, allow the device to warm up for at least 15 minutes after powering on before taking precise measurements or conducting critical tests.
- Voltage Compatibility: Verify that the input voltage from your local power grid matches the specified AC input requirement of the power supply (AC 110V ±10% 50Hz/60Hz).
Operating Instructions
Adjusting Voltage and Current
- Rotate the Adjustment Knob (12) to change the desired voltage or current value.
- Press the Adjustment Knob (12) to confirm the digit you are currently setting.
- Press the Voltage Regulation Button (13) to select and set the voltage value. The digits will flash briefly once successfully set.
- Press the Current Regulation Button (14) to select and set the current value. The digits will flash briefly once successfully set.
Output Switch Control
Use the ON/OFF button (7) on the front panel to turn the output power on or off. This button remains functional even when the unit's controls are locked.
Parameter Storage (M1/M2/M3)
The device allows you to save and recall three sets of parameters (voltage, current, etc.) using the M1, M2, and M3 buttons (6).
- Saving a Value:
- Set the desired voltage and current values using the adjustment knob and regulation buttons.
- Long press one of the M1, M2, or M3 buttons (6) until its indicator light turns on. This confirms the values have been successfully saved to that memory slot.
- Reading a Value:
- Press the desired M1, M2, or M3 button (6) to light its indicator. The saved values will then be loaded and displayed on the screen.
Over Current Protection (OCP) Setup
- Press the OCP setting button (4) to enable the function. The button will illuminate red when enabled.
- Rotate the Adjustment Knob (12) to set the desired OCP value.
- If the output current exceeds the set OCP value, the screen will display "OCP" and the output will be cut off.
- Press the ON/OFF button (7) to reset the OCP state and restore output.
- To disable OCP, press the OCP setting button (4) again. The button's red light will turn off.
Over Voltage Protection (OVP) Setup
- Press the OVP setting button (5) to enable the function. The button will illuminate red when enabled.
- Rotate the Adjustment Knob (12) to set the desired OVP value.
- If the output voltage exceeds the set OVP value, the screen will display "OVP" and the output will be cut off.
- Press the ON/OFF button (7) to reset the OVP state and restore output.
- To disable OVP, press the OVP setting button (5) again. The button's red light will turn off.
Lock/Unlock Function
To prevent accidental changes to settings during operation, you can lock the control buttons.
- Locking: Long press the Adjustment Knob (12) to lock the buttons. The Locked State Indicator (11) will illuminate. In this locked state, only the ON/OFF button (7) remains functional.
- Unlocking: Long press the Adjustment Knob (12) again to unlock the buttons. The Locked State Indicator (11) will turn off.
- It is recommended to lock the buttons before starting critical work to ensure the accuracy and stability of power values.
USB Output
The USB Charge Port (8) provides a convenient fast charging interface for compatible devices. Ensure your device supports USB charging before connecting.
Maintenance
Fuse Replacement
If the power supply fails to turn on or operate, and you suspect a blown fuse:
- Turn off the DC power supply using the Power On/Off Switch (17) on the rear panel and disconnect the AC input cable from the wall outlet.
- Locate the Fuse Box (20) on the rear panel.
- Carefully remove the fuse box (often by prying it out or unscrewing) and replace the blown fuse with a new one of the correct type and rating. Refer to the specifications for the correct fuse type.
- If the power supply still does not function after fuse replacement, or if you are unsure about the process, it is strongly recommended to seek professional assistance.

General Care
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Store and operate the device in a dry environment, away from moisture and extreme temperatures.
- Do not expose the device to corrosive gases or harmful substances, as this can damage internal components.
Troubleshooting
Q1: Why doesn't the digital display work properly?
A1: Check the input voltage to determine if it is functioning correctly and within the specified range (AC 110V ±10% 50Hz/60Hz). Ensure the power cable is securely connected.
Q2: Why does the C.C. (Constant Current) indicator light up?
A2:
- When operating in constant voltage (C.V.) mode, if the output voltage is set too low, it can trigger current protection, causing the C.C. indicator (10) to light up.
- The DC power supply automatically switches to constant current (C.C.) mode to protect the product and the connected load.
- To resolve, check and increase the maximum current setting according to your needs. Press the Current Regulation Button (14) and rotate the Adjustment Knob (12) to adjust the current.
Q3: Why does the C.V. (Constant Voltage) indicator light up?
A3:
- When operating in constant current (C.C.) mode, if the output current is set too low, it can trigger voltage protection, causing the C.V. indicator (9) to light up.
- The DC power supply automatically switches to constant voltage (C.V.) mode to protect the product and the connected load.
- To resolve, check and increase the maximum voltage setting according to your needs. Press the Voltage Regulation Button (13) and rotate the Adjustment Knob (12) to adjust the voltage.
General Issues
If you encounter a serious problem that cannot be resolved using the troubleshooting steps above, please contact the seller or manufacturer for assistance. Do not attempt to repair the unit yourself unless you are a qualified professional.
Specifications
The MYAMi Programmable DC Power Supply is available in various models, each with specific output capabilities. Below are the general specifications applicable to the series, followed by model-specific output ranges.
General Specifications:
| Parameter | Value |
|---|---|
| Output Power Range | 150-500W (specific models 201-300W) |
| Application | Rectifier, Power Supply |
| EU LVD Voltage | High voltage: Above 50Vac or 75Vdc |
| Rated Capacity | 40-1000VA (including 40VA) |
| Output Current Range | 0-10A (varies by model) |
| Brand Name | MYAMi |
| Output Type | SINGLE |
| Origin | Mainland China |
| Certification | CE |
| Color | Black/White |
| Voltage Regulation | ≤0.5%+5mV |
| Line Regulation (Voltage) | ≤0.05%+5mV |
| Load Regulation (Voltage) | ≤0.1%+10mV |
| Setting Resolution (Voltage) | 10mV |
| Feedback Accuracy (Voltage) | ≤0.5%+1 digit |
| Ripple and Noise (Voltage) | ≤10mVrms |
| Current Regulation | ≤0.5%+3mA |
| Line Regulation (Current) | ≤0.2%+3mA |
| Load Regulation (Current) | ≤0.2%+3mA |
| Setting Resolution (Current) | 1mA |
| Feedback Accuracy (Current) | ≤0.2%+3mA |
| Ripple and Noise (Current) | ≤3mArms |
| OVP Max. Output Voltage | 0-Vmax±0.2%FS |
| OCP Max. Output Current | 0-Cmax±0.2%FS |
| Operating Temperature Range | 0°C to 40°C, ≤80% RH |
| Suggested Operating Temperature | 23°C Earth 5°C |
| Storage Temperature Range | -20°C to 60°C, ≤80% RH |
| Weight | 1.95KG±0.05KG |
| Dimensions (L*W*H) | 80*150*230 mm |
Model-Specific Output Ranges (HP Model Range):
| HP Model | V-Output (0-Vmax) | C-Output (0-Amax) | P-Output (0-Pmax) |
|---|---|---|---|
| 40V/20A | 0-40V | 0-20A | 0-300W |
| 80V/10A | 0-80V | 0-10A | 0-300W |
| 160V/5A | 0-160V | 0-5A | 0-300W |
Model-Specific Output Ranges (MP Model Range):
| Model | Output Voltage | Output Current | Communication |
|---|---|---|---|
| MY-K1502MP (15V/2A) | 0-15V | 0-2A | USB |
| MY-K1505MP (15V/5A) | 0-15V | 0-5A | USB |
| MY-K3005MP (30V/5A) | 0-32V | 0-5A | USB |
| MY-K3010MP (30V/10A) | 0-32V | 0-10A | USB |
| MY-K6005MP (60V/5A) | 0-64V | 0-5A | USB |
| MY-K10003MP (100V/3A) | 0-102V | 0-3A | USB |
| MY-K1520MP (15V/20A) | 0-15V | 0-20A | USB |
| MY-K15002MP (150V/2A) | 0-150V | 0-2A | USB |

User Tips
- Connection Safety: Always double-check your connections and ensure proper grounding before powering on to prevent damage to the power supply or the connected circuit.
- Parameter Presets: Utilize the parameter storage (M1-M3) functions for frequently used voltage/current settings to save time and ensure consistent accuracy across repeated tasks.
- Lock Function: Engage the lock function (11) when performing critical tests or when leaving the device unattended to prevent accidental adjustments that could harm your circuit or the power supply.
- Troubleshooting Start Point: When troubleshooting, always start by checking the most basic elements like input power, fuse integrity, and secure connections before delving into more complex issues.
- Environmental Awareness: Keep the power supply in a clean, dry, and well-ventilated area to ensure its longevity and reliable performance.
Warranty and Support
For detailed warranty information, technical support, or assistance with issues not covered in this manual, please refer to the official user manual PDF or contact MYAMi Official Store directly.
A comprehensive user manual in PDF format is available for download: View User Manual (PDF)