ASAIR AGP3000

Contents

ASAIR AGP3000 MEMS Digital Display Resistor Pirani Vacuum Gauge Instruction Manual

Model: AGP3000 | Brand: ASAIR

1. Introduction

1.1 Product Brief

The AGP3000 is a wide-range pressure measurement Pirani composite vacuum gauge that integrates an advanced pressure sensor module and MEMS Pirani vacuum sensor chip. This vacuum meter is not only powerful but also easy to operate. It is equipped with a color LCD screen (TFT-LCD) and intuitive button control, providing analog voltage output and RS485 communication protocol, facilitating users to connect and exchange data with various devices and systems.

The AGP3000 supports switching between Pa, Torr, and mbar units and is equipped with a standard KF16 pressure interface. Different adapters can be selected as needed to ensure seamless docking with various equipment and systems. Before leaving the factory, the accuracy, repeatability, response time, and other indicators of the AGP3000 have been strictly tested and calibrated to ensure excellent performance.

1.2 Key Features

  • Pressure measurement from 0.05 Pa to 120 kPa
  • Rapid, accurate, reproducible, and long-term stable pressure measurements
  • TFT-LCD color screen display
  • 0-10V analog signal linear output
  • Standard Modbus RTU communication
  • Easy to install
  • Low power consumption
  • High precision
  • Excellent stability
  • Good repeatability
  • Lightweight and easy maintenance

1.3 Application Areas

The AGP3000 Pirani composite vacuum meter is widely used in a variety of precision measurement scenarios with medium and low vacuum requirements. These include:

  • Vacuum baking
  • Vacuum packaging
  • Vacuum coating
  • Vacuum heat treatment
  • Vacuum brazing
  • Metal smelting
  • Semiconductor intelligent equipment
  • Photovoltaic equipment
  • Other industrial fields

1.4 Product Overview Video

Video: Introduction to the ASAIR AGP3000 Pirani Vacuum Gauge, highlighting its features and applications.

2. Setup

2.1 Appearance and Structure

The AGP3000 features an LCD display and three operation buttons. From left to right, these buttons function as: Up/Left, Down/Right, and Confirmation/Return. The device is compact and designed for easy integration.

Front view of the AGP3000 Pirani Vacuum Gauge with display and buttons

Figure: Front view of the AGP3000 Pirani Vacuum Gauge, showing the display and control buttons.

2.2 DB9 Interface Pin Definition

The communication interface of the AGP3000 is a standard DB9 header. The pin definitions are crucial for correct wiring:

Table: DB9 Interface Pin Definition
PinDescription
1Signal positive pole
2RS485 Communication port A
3RS485 Communication port B
49~24 V DC power supply cathode
5, 7, 8GND
69~24 V DC power supply negative electrode
9Signal negative electrode

2.3 Lead Line Definition

The lead line for the AGP3000 uses a DB9 female head and UL2464 material, with 9 lines. The color coding for these lines is as follows:

Table: AGP3000 Lead Line Definition
Lead ColorDefinition
BlackSignal positive pole
BrownRS485 Communication port A
RedRS485 Communication port B
OrangePower positive pole
Yellow, Blue, GrayGND
GreenPower anode
WhiteSignal negative electrode
AGP3000 Pirani Vacuum Gauge with DB9 lead line and transfer kit

Figure: AGP3000 Pirani Vacuum Gauge with DB9 lead line and optional transfer kit.

2.4 Flange Interface

The pressure interface is a standard KF16 flange, made of 304 stainless steel with an electropolished surface. This design ensures high vacuum sealing, convenient installation, and easy disassembly. Various optional connectors are available for KF16 to other interfaces, such as KF16-KF25, KF16-KF40, and various VCR/NPT/VCO types. Contact the manufacturer for specific adapter needs.

3. Operating Instructions

3.1 Work Interface and Navigation

Upon powering up, the AGP3000 displays the home page showing the current air pressure value, device address, communication rate, and current display unit. Use the left or right buttons to navigate the primary menu (Setting, Status, Return). Selecting a function leads to a corresponding secondary menu, and so on. In the Setting menu, you can adjust the product communication address, communication rate, and display pressure value unit. Use the Confirmation/Return button to save settings and return to the previous menu.

Interface Display Summary

Table: AGP3000 Interface Display Summary
ItemDescription
Vacuum degree display interfaceShows current pressure, ID, and unit (e.g., 1.01e+05 Pa)
Level 1 menuAccesses main menu options (Setting, Status, Return)
Device address adjustment pageAdjusts the device address (1-255)
Communication rate regulation pageAdjusts communication rate (4800, 9600, 19200, 115200bps)
Unit setting adjustment pageChanges pressure display units (Pa, Torr, mbar)
Status barDisplays real-time data: operating voltage (V1), current (I), sensor resistance (R), sensor operating voltage (V2), lower limit of calibration (LAD), upper limit of calibration (HAD)
ReturnReturns to the main page or previous menu level

3.2 RS485 Communication

The AGP3000 uses standard Modbus RTU communication. The device acts as a slave with a default address of 1 (0x01), supporting address modification up to 255 (0xFF). This allows access to multiple devices on the bus.

Modbus RTU Register Definitions

Table: Modbus RTU Register Definitions
NameRegister AddressByte Length and TypeRead/Write AttributesFC
Pressure value0x000032bits (float)Read only03
AD value0x000232bits (float)Read only03
Real-time state0x00048bits (byte)Read only03
Device address0x00058bits (byte)Read only03
Communication rate0x000616bits (short)Read only03

Common Modbus RTU Instructions

Table: Common Modbus RTU Instructions
Command FunctionInstruction (Hex)
Calibration at 0.1PaFF 10 00 11 00 03 06 AA F1 00 00 00 00
Under constant pressure calibrationFF 10 00 11 00 03 06 AA F2 00 00 00 00
Write to flashFF 10 00 11 00 03 06 AA FE 00 00 00 00
Read address-1 sensor pressure value01 03 00 00 00 02 C4 0B
Read current device address01 03 00 05 00 01 94 0B
Read current device communication rate01 03 00 06 00 01 64 0B

3.3 Analog Voltage Output

The AGP3000 provides a 0-10V analog voltage output (U, in VDC). The voltage output is a function of pressure (P, in Pa), with the conversion formula: P = 10^((U-6.143)/1.286+2)U = log10 (P/100) × 1.286 + 6.143. A characteristic curve illustrating this relationship is available in the full user manual.

4. Maintenance

4.1 Precautions for Use

  • When purchasing, specify any requirements for different transfer parts.
  • The vacuum gauge supports installation in any direction; vertical installation is recommended for optimal performance.
  • During installation, ensure that the surfaces of the clamp, sealing ring, or other connecting devices are clean and undamaged to prevent air leakage.
  • Ensure the power supply voltage is stable and within the operating voltage range (9-24V) during use.
  • Do not exceed the maximum allowable pressure during operation.
  • In case of product problems, do not disassemble or repair without permission. Contact the manufacturer for assistance.

5. Troubleshooting

No specific troubleshooting steps are provided in the available documentation. If you encounter issues with your AGP3000 Pirani vacuum gauge, please refer to the 'Maintenance' section for general precautions and contact the manufacturer for support.

6. Specifications

6.1 Technical Indicators and Mechanical Parameters

Table: AGP3000 Technical Indicators and Mechanical Parameters
ParameterDescription
Measuring range (N2 and air)5 × 10^-2 ~ 1.2 × 10^5 Pa
Precision (N2)
  • 5×10^-2 ~ 1×10^-1 Pa (error is ±50% of readings)
  • 1×10^-1 ~ 1.5×10^4 Pa (error is ±15% of readings)
  • 1.5×10^4 ~ 1.2×10^5 Pa (error is ±0.5% of readings)
Repeatability (N2)1×10^-1 ~ 1.2×10^5 Pa (error is ±2% of readings)
Response time≤100ms
Communication interfaceDB9 (optional DB9 lead)
Output signalRS485, 0~10VDC
Display unitPa, Torr, mbar, switchable
Pressure interfaceKF16 (optional KF16 adapter/connector)
Supply voltage9~28 VDC
Power dissipation<1.2W
Working temperature0~40 °C
Preheating time60s
Load pressure130KPa
Case materialAluminum

Note: Precision and repeatability values are typical data measured in a room temperature nitrogen environment after calibration.

6.2 Dimensions

The AGP3000 has a compact design. The main dimensions are approximately:

  • Diameter: 30.0 mm
  • Length (excluding flange): 51.0 mm
  • Total Length (including flange): 67.5 mm
  • Tolerance: ±0.5mm

7. User Tips

Based on available user feedback, no specific tips or common usage advice can be extracted at this time. Always ensure proper installation and adherence to the operating voltage range for optimal performance.

8. Warranty and Support

8.1 Quality Assurance

Guangzhou Aosong Electronics Co., Ltd. provides a quality assurance period of 12 months from the date of delivery for the AGP3000 Pirani composite vacuum meter. This warranty covers defects in accordance with the technical specifications outlined in the product documentation. If the product is found to be defective during this period, the company will provide free repair or replacement services.

The company is responsible for the application of the product under its specified technical conditions. It does not guarantee product application in non-recommended special scenarios and makes no commitment to the reliability of products used with other supporting products or circuits.

8.2 Warning and Personal Injury

This product should not be used in safety protection devices, emergency stop equipment, or any other application where product failure could lead to personal injury, unless specifically authorized. Always refer to the product data sheet and instructions before installation, processing, use, or maintenance. Failure to comply with these recommendations may result in death or serious personal injury. The Company will not be liable for personal injury or death arising from such misuse and will be exempt from any claims against its managers, employees, and affiliated agents.

8.3 Further Support

This manual is subject to change without prior notice. The right of final interpretation of this product belongs to Guangzhou Aosong Electronics Co., Ltd. For any issues or further support, please contact the manufacturer directly.

Copyright © 2024, ASAIR ®

For the full user manual in PDF format, please refer to the official document: User manual (PDF)


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.