ATTEN ST-1202

ATTEN ST-1202 Dual-Channel Smoke Purifier

Model: ST-1202 | Brand: ATTEN

1. Introduction

The ATTEN ST-1202 is a high-performance dual-channel smoke purifier and solder filter designed to effectively remove harmful fumes and particles generated during soldering and other industrial processes. Featuring an integrated metal frame, a powerful DC brushless fan, and a multi-layer filtration system, it ensures a cleaner and safer working environment. This manual provides essential information for the proper setup, operation, and maintenance of your ST-1202 unit.

2. Key Features

  • Integrated design with durable metal frame.
  • Equipped with directional wheels and rubber feet for stability and mobility.
  • High-power DC brushless fan for efficient fume extraction and low noise operation.
  • Large LCD display screen for easy monitoring.
  • Advanced 3-layer filtration system with a purification rate of up to 99.97% for 0.3 micron particles.
  • Quick and easy replacement of individual filter layers.
  • Filter blockage alarm for timely maintenance alerts.
  • Supports two independent working positions with flexible extraction arms.
  • Adjustable air volume and flow control.
  • Wind wheel made of special alloy to prevent corrosion.

3. Product Overview and Components

The ATTEN ST-1202 unit consists of the main body, two flexible extraction arms with nozzles, a control panel, and a multi-layer filter system. The main body houses the fan, motor, and filter compartments. The control panel allows for power control and air volume adjustment.

Front view of the ATTEN ST-1202 dual-channel smoke purifier with two flexible extraction arms.

Figure 1: Front view of the ST-1202 with dual extraction arms.

Side view of the ATTEN ST-1202 smoke purifier with flexible extraction arms extended.

Figure 2: Side view of the ST-1202 with extended arms.

Rear view of the ATTEN ST-1202 smoke purifier showing the exhaust port and power input.

Figure 3: Rear view of the ST-1202.

Video 1: Demonstration of the ATTEN ST-1202's flexible extraction arms and overall design.

4. Setup Instructions

  1. Unpacking: Carefully remove the smoke purifier from its packaging. Retain all packaging materials for future transport or storage.
  2. Placement: Place the unit on a stable, level surface. Ensure there is adequate space around the unit for proper airflow and maintenance access.
  3. Arm Installation: Insert the flexible extraction arms into the designated ports on the top of the unit. Ensure they are securely fitted.
  4. Nozzle Adjustment: Position the nozzles of the extraction arms close to the source of fumes (e.g., soldering point) for optimal capture. The flexible pipes can be adjusted to various angles and positions.
  5. Power Connection: Connect the power cord to the unit and then to a suitable 220V EU PLUG power outlet.
  6. Initial Filter Check: Before first use, ensure all three filter layers (Pre-filter, Middle filter, Main filter) are correctly installed in their respective compartments. Refer to the 'Maintenance' section for filter orientation.

5. Operating Instructions

  1. Power On: Press the power button on the control panel to turn on the unit. The LCD screen will illuminate.
  2. Adjust Air Volume: Use the control knob on the panel to adjust the air volume and suction power according to your needs. Start with a lower setting and increase as required for effective fume extraction.
  3. Positioning: During operation, ensure the extraction nozzles are positioned as close as possible to the fume source to maximize capture efficiency.
  4. Monitoring: Observe the LCD display for any alerts, such as a filter blockage alarm, which indicates that a filter needs inspection or replacement.
  5. Power Off: After use, press the power button to turn off the unit.

6. Maintenance

Regular maintenance is crucial for the optimal performance and longevity of your ATTEN ST-1202 smoke purifier. Pay close attention to filter replacement schedules.

6.1 Filter System Overview

The unit utilizes a triple-layer filtration system:

  • Pre-filter: Captures larger particles.
  • Middle filter: Captures medium-sized particles.
  • Main filter: Captures fine particles and absorbs harmful gases.
Diagram showing the three filter layers (Pre-filter, Middle filter, Main filter) and their recommended replacement cycles.

Figure 4: Filter layers and recommended replacement cycles.

6.2 Filter Replacement

The sequence of filters must be subject to the right diagram. Disorganization is strictly forbidden. The relatively dense side of the pre-filter faces down.

Suggested Replacement Cycles:

  • Pre-filter: Every 10-15 days
  • Middle filter: Every 3-6 months
  • Main filter: Every 6-9 months

Remark: The actual replacement cycles of filters shall be subject to the pollution levels of different sites and usage frequency. The unit's filter blockage alarm will also indicate when a filter needs attention.

6.3 Cleaning

Regularly wipe the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the unit is powered off and unplugged before cleaning.

7. Specifications

Technical Specifications for ST-1101 and ST-1202
Item NoST-1101ST-1202
Voltage230V230V
Power160W180W
Work positions12
Air Flow240m³/H (±10%)150m³/H*2 (±10%)
Filtration efficiency (0.3 micron)99.97%99.97%
Dimension465x250x480mm465x250x480mm
N.W.17kg18.2kg

8. Troubleshooting

ProblemPossible CauseSolution
Unit does not power onNo power supply; Power cord loose; Unit faultCheck power connection and outlet; Ensure power cord is securely plugged in; Contact customer support if problem persists.
Low suction powerFilters are clogged; Air volume setting too low; Obstruction in arms/nozzlesCheck and replace filters as needed; Increase air volume setting; Clear any obstructions from the arms or nozzles.
Filter blockage alarm activatesOne or more filters are saturated/cloggedInspect and replace the indicated filter(s) immediately.
Unusual noise during operationForeign object in fan; Fan malfunctionPower off and unplug the unit. Carefully inspect for foreign objects. If noise persists, contact customer support.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation provided at the time of purchase or contact your authorized ATTEN dealer. Keep your purchase receipt as proof of purchase.

Related Documents - ST-1202

Preview ATTEN ST-2090D Soldering Station User Manual - Features, Operation, and Safety
Comprehensive user manual for the ATTEN ST-2090D Soldering Station. Learn about its features, operational guide, safety precautions, specifications, and troubleshooting. Includes detailed descriptions of diagrams and controls.
Preview ATTEN ST-7500/ST-7800 Preheating & Reflow Platform User Manual
Official user manual for the ATTEN ST-7500 and ST-7800 Preheating & Reflow Platforms. Provides comprehensive guidance on operation, specifications, safety, and troubleshooting for professional electronic rework.
Preview Atten ST-965 Soldering Station User Manual
User manual for the Atten ST-965 65 Watt soldering station, listing included components and specifications.
Preview ATTEN ST-862D Hot Air Station User Manual - Operation and Maintenance Guide
Comprehensive user manual for the ATTEN ST-862D Hot Air Station, covering operation, settings, maintenance, troubleshooting, and technical specifications. Learn how to use and care for your rework station.
Preview Atten GT-1028 Hot Air Station with Vacuum Pen User Manual
User manual for the Atten GT-1028 hot air station and vacuum pen, detailing features, specifications, operation, safety, and troubleshooting for electronics repair and rework.
Preview ATTEN ST-862D Hot Air Station User Manual - Operation and Safety Guide
Comprehensive user manual for the ATTEN ST-862D Hot Air Station, covering operation, technical specifications, safety precautions, maintenance, and warranty information for electronics rework and repair.