Mestek TI120

Contents

Mestek TI120 Thermal Imager User Manual

Model: TI120 | Brand: Mestek

1. Introduction

Thank you for choosing the Mestek TI120 Thermal Imager. This device is a handheld, dual-mode infrared and visible light imaging camera designed for accurate temperature measurement and analysis. It features a 3.5-inch color display, automatic hot and cold spot tracking, and USB connectivity for data export. This manual provides essential information for the safe and effective use of your thermal imager.

2. Safety Information

Please read and understand all safety warnings and operating instructions before using this product. Failure to follow these instructions may result in injury or damage to the device.

  • Do not point the thermal imager directly at strong light sources (e.g., the sun, lasers) as this may damage the sensor.
  • Keep the device away from water and moisture.
  • Do not attempt to disassemble or modify the device. Repairs should only be performed by qualified personnel.
  • Use only the provided charging cable and power adapter.
  • Ensure the operating environment is within the specified temperature and humidity ranges.

3. Package Contents

Verify that all items are present in your package:

  • 1 x Thermal Imaging Host (Mestek TI120)
  • 1 x Cloth Bag
  • 1 x Color Box
  • 1 x Charging/Data Cable (USB Type-C)
  • 1 x Leather Strap
  • 1 x Certificate
  • 1 x Lens Cleaning Cloth
  • 1 x Multilingual Manual
Mestek TI120 Thermal Imager package contents
Figure 3.1: Included accessories and packaging.

4. Product Overview

The Mestek TI120 is a versatile thermal imager equipped with both infrared and visible light cameras, displayed on a clear 3.5-inch color screen. It supports various imaging modes and features for comprehensive temperature analysis.

4.1 Device Layout

Mestek TI120 Thermal Imager labeled parts
Figure 4.1: Front and rear view of the TI120 with labeled components.
  1. 3.5 inch screen
  2. On/off key (Long press to power on/off)
  3. LED light switch (Short press to turn on/off, toggle between 1st/2nd gear brightness)
  4. Image storage record (Short press to enter picture storage, long press to delete current image)
  5. Return key (Short press to return to previous menu)
  6. Setting buttons (Short press to enter settings menu or data settings)
  7. Up/down/left/right keys (Used for navigation and viewing image history)
  8. LED lighting
  9. Infrared camera
  10. Visible light camera
  11. Camera cover
  12. Tripod screw holes
  13. Shooting key (Short press to capture and save the current scene)

4.2 Key Features

  • Dual Camera: Infrared and Visible Light for enhanced imaging.
  • Large Storage: Capable of storing up to 2000 images.
  • Strong Battery Life: Built-in rechargeable lithium battery provides up to 10 hours of use.
  • USB Type-C: For convenient charging and data transfer.
  • Hot and Cold Automatic Tracking: Automatically identifies and tracks the hottest and coldest spots.
  • High and Low Temperature Alarm: Alerts when temperatures exceed set thresholds.
  • Emissivity Adjustable: Allows for more accurate measurements based on material.
  • 3.5-inch Color Screen: Clear and intuitive display.
  • External Micro SD Card: For expanded storage.
Mestek TI120 Thermal Imager key features summary
Figure 4.2: Summary of TI120 features.

5. Setup

5.1 Charging the Device

Before first use, fully charge the thermal imager. Connect the provided USB Type-C cable to the device's charging port and the other end to a suitable USB power adapter (e.g., 5V/1A). The battery indicator on the screen will show charging status. A full charge can provide up to 10 hours of operation.

Mestek TI120 Thermal Imager charging via USB-C
Figure 5.1: Charging the TI120.

5.2 Powering On/Off

  • To Power On: Long press the On/off key (2) until the screen illuminates.
  • To Power Off: Long press the On/off key (2) until the device shuts down.

6. Operating Instructions

6.1 Menu Navigation

To access the settings menu, press the SET button (6). Use the Up/down/left/right keys (7) to navigate through options and the SET button to confirm selections. Press the Return key (5) to go back to the previous menu or exit the menu.

Mestek TI120 Thermal Imager menu operation instructions
Figure 6.1: Menu operation instructions.

6.2 Imaging Modes

The TI120 supports dual camera mode, allowing you to switch between infrared thermal imaging and visible light imaging, or a fusion of both. This helps in accurately identifying fault points and problem areas.

  • Infrared Thermal Imaging: Displays temperature distribution.
  • Visible Light Imaging: Provides a standard visual image.
  • Fusion Modes: Blends infrared and visible light images at various percentages (e.g., 0% visible light/100% infrared, 25% fusion, 50% fusion, 75% fusion, 100% visible light).
Mestek TI120 Thermal Imager dual camera display
Figure 6.2: Dual camera display modes.
Mestek TI120 Thermal Imager infrared and visible light display adjustable
Figure 6.3: Adjustable infrared and visible light display options.

6.3 Color Palettes

The device offers six color imaging modes (palettes) to visualize temperature differences. Press the Up/down/left/right keys (7) to switch between these palettes:

  • Red Hot
  • High Contrast Rainbow
  • Rainbow
  • Lava
  • Iron Red
  • White Hot
Mestek TI120 Thermal Imager palette options
Figure 6.4: Six color imaging modes.

6.4 Automatic Tracking and Alarm

The TI120 automatically tracks the central, highest, and lowest temperature points within the field of view. You can set maximum and minimum temperature thresholds. If the measured temperature exceeds these values, an alarm icon will be displayed on the screen.

Mestek TI120 Thermal Imager hot and cold automatic tracking and alarm
Figure 6.5: Automatic tracking and temperature alarm.

6.5 Capturing and Storing Images

To capture an image, short press the Shooting key (13). The device has mass storage for up to 2000 photos. Short press the Image storage record key (4) to enter the picture storage record. Long press the Image storage record key (4) to delete the current image.

Mestek TI120 Thermal Imager mass storage
Figure 6.6: Image storage capability.

6.6 Data Export to Computer

Stored images can be transferred to a computer using the USB data cable. Connect the device to your computer via the USB Type-C port. The image transfer speed is up to 12Mbps/sec.

Mestek TI120 Thermal Imager USB data export
Figure 6.7: Connecting the TI120 to a computer for data export.

6.7 LED Lighting

The built-in LED lighting (8) provides illumination in dark environments. Short press the LED light switch (3) to turn it on, and press again to cycle through two brightness levels and off.

Mestek TI120 Thermal Imager bright LED lighting
Figure 6.8: Bright LED lighting feature.

7. Emissivity Adjustment

Emissivity is a measure of an object's ability to emit infrared energy. Adjusting the emissivity setting based on the target material ensures higher accuracy in temperature measurements. You can adjust this setting in the menu.

7.1 Common Object Emissivity Table

MaterialEmissivityMaterialEmissivity
Wood0.85Black paper0.86
Water0.96Polycarbonate0.80
Brick0.75Concrete0.97
Stainless steel0.14Copper oxide0.78
Adhesive tape0.96Cast iron0.71
Aluminum plate0.09Rust0.80
Copper plate0.06Plaster0.75
Black aluminum0.95Paint0.90
Human skin0.98Rubber0.95
Asphalt0.96Soil0.93
PVC plastic0.93
Mestek TI120 Thermal Imager emissivity table
Figure 7.1: Emissivity values for common materials.

8. Maintenance

  • Cleaning: Use the provided lens cleaning cloth to gently wipe the camera lenses. For the device body, use a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Storage: When not in use for extended periods, store the device in its cloth bag in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use.

9. Troubleshooting

If you encounter issues with your Mestek TI120, please refer to the following common problems and solutions:

  • Device does not power on: Ensure the battery is charged. Connect the device to a charger and try again. If the issue persists, contact support.
  • Image is unclear or blurry: Check if the camera lenses are clean. Use the provided lens cloth to gently clean them. Ensure you are within the optimal detection distance (0.5m-1.2m).
  • Temperature readings seem inaccurate: Verify that the emissivity setting matches the material being measured. Ensure the ambient temperature is within the operating range.
  • Cannot transfer data to computer: Check the USB cable connection. Ensure the device is powered on and recognized by your computer. Try a different USB port or cable.
  • Screen is unresponsive: Try restarting the device by long-pressing the power button.

10. Specifications

ParameterValue
Product NameHandheld Infrared Thermal Imager
Thermal Imaging Pixels10800 (120*90)
Spectral Response Band8-14μm
Field of View50° * 63.4°
Cell Size17um
Output Frame Rate≤ 20Hz
Thermal Sensitivity≤ 60mK
Measure Working Environment Temp0-35°C
Temperature Measurement Range-20~400°C
Temperature Measurement Accuracy1) -20°C~0°C: ± 5°C
2) 0°C~100°C: ± 3°C
3) 100°C~120°C: ± 5%
Best Detection Distance Range0.5m-1.2m
PaletteSix Color Imaging Palettes
High and Low Temperature Alarm√
SENSOR Non-uniformity< 5%
Size3.5 inch
Display Resolution320*240
Visible Light Resolution30W (640*480)
StorageExternal 8G Micro SD Card
Storage MemorySDRAM: 256Mbit + SPI
Communication InterfaceNORFLASH: 64Mbit
Powered ByUSB2.0 (FS)
LED Lighting26650 lithium battery; 5000mAh/3.7V
Waterproof LevelHigh power white LED
Operating TemperatureIP65
-10 ~ 50°C; - 40 ~ 70°C
Anti-drop1.5m
Size238*95*85.5mm
Weight540g
Mestek TI120 Thermal Imager product parameters
Figure 10.1: Detailed product specifications.

11. Wide Range of Applications

The Mestek TI120 Thermal Imager is suitable for various professional and home inspection tasks, including:

  • Equipment Maintenance
  • Power Detection
  • Floor Heating Detection
  • Pipeline Maintenance
  • Electronic Component Testing
  • Automobile Fault Detection
Mestek TI120 Thermal Imager applications
Figure 11.1: Examples of TI120 applications.

12. User Tips

  • For best results, ensure the target object fills a significant portion of the screen when taking measurements.
  • Experiment with different color palettes to find the one that best highlights the temperature differences for your specific application.
  • Regularly check for firmware updates to ensure optimal performance and access to new features.

13. Warranty and Support

Your Mestek TI120 Thermal Imager comes with a standard manufacturer's warranty. Please refer to the warranty card included in your package for specific terms and conditions. For technical support, troubleshooting assistance, or warranty claims, please contact your retailer or the manufacturer's customer service department.

14. Manufacturing Process

The following video provides a glimpse into the manufacturing process of Mestek products, showcasing the assembly line and quality control measures.

Video 14.1: Mestek factory production line.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.