1. Introduction

The Sugon 3005PM is a high-precision adjustable switching DC power supply designed for various electronic applications, including cell phone repair, laptop maintenance, PCB repair, laboratory testing, and general electronic repair. It features a 4-digit LED display, continuously adjustable voltage and current outputs, and multiple USB ports for convenience.

2. Safety Information

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Ensure the power supply is connected to a grounded outlet.
  • Do not operate the device in wet or damp conditions.
  • Do not open the casing of the power supply; there are no user-serviceable parts inside. Refer servicing to qualified personnel.
  • Verify the input voltage matches your local power supply (AC 110V or AC 220V).
  • Avoid short-circuiting the output terminals.
  • Keep the ventilation openings clear to prevent overheating.

3. Package Contents

Verify that all items are present in the package:

  • 1 x Sugon 3005PM DC Power Supply
  • 1 x Power Cable

4. Product Overview

The Sugon 3005PM features a clear 4-digit LED display and intuitive controls for precise operation.

Front Panel Layout

Front panel diagram of Sugon 3005PM DC Power Supply with labels for display, knobs, buttons, and USB ports.
Figure 4.1: Front Panel Controls and Display
  • Power Display: Shows the current power output in Watts.
  • Current Display: Shows the current output in Amperes.
  • Voltage Display: Shows the voltage output in Volts.
  • Status Indicator: LED indicators for various modes (CONT.OCP, ONCE.OCP, C.C., C.V.).
  • Voltage Adjustment Knob: Used to adjust the output voltage.
  • Current Adjustment Knob: Used to adjust the output current.
  • 8.4V-30V Limited Switch: Limits the output voltage range.
  • Constant Current and Constant Voltage Mode Button: Toggles between CC and CV modes.
  • Once Overcurrent Protection Button: Activates single overcurrent protection.
  • Continuous Overcurrent Protection Button: Activates continuous overcurrent protection.
  • Adjustable USB Output: Six USB ports with adjustable voltage (0V-30V).
  • Fixed 5V USB Output: Two fixed 5V/2A USB output ports (A and B).
  • Power Switch: Main power on/off.
  • Save Keys (M1, M2, M3, M4): Memory buttons for storing and recalling settings.

Rear Panel Layout

Rear panel diagram of Sugon 3005PM DC Power Supply showing cooling fan, AC power input, and fuse box.
Figure 4.2: Rear Panel Components
  • Cooling Fan: For heat dissipation.
  • AC Power Input: Connects to the main power supply.
  • Fuse Box: Contains the protective fuse.

5. Specifications

FeatureSpecification
ModelSUGON 3005PM
Power150W
Maximum CurrentDC 5A
Output Voltage RangeDC 0-30V (continuously adjustable)
Input Voltage (American Standard)AC 110V, 50Hz/60Hz
Input Voltage (National/European Standard)AC 220V, 50Hz/60Hz
DisplayLED Four-Digit Display (Voltage, Current, Power)
USB Ports6 x Adjustable USB outputs (0V-30V), 2 x Fixed 5V/2A USB outputs
Protection FeaturesOvervoltage Protection (OVP), Overcurrent Protection (OCP), Overload Protection (OPP), High-Temperature Protection
Memory Functions4 memory buttons for voltage, current, and protection settings
Product Dimensions230 x 125 x 25mm
Weight5.1 KG
MaterialMetal
DIY SuppliesElectrical
Icons representing OVP, OCP, OPP, High Temperature Protection, LED four-digit display, four stored memories, 24h full load operation, and low ripple and low noise.
Figure 5.1: Key Features and Protection Mechanisms

6. Setup

  1. Unpacking: Carefully remove the power supply and all accessories from the packaging.
  2. Placement: Place the power supply on a stable, level surface with adequate ventilation. Ensure that the cooling fan at the rear and side vents are not obstructed.
  3. Power Connection: Connect the provided power cable to the AC power input on the rear panel of the device and then to a suitable grounded electrical outlet. The device supports both AC 110V and AC 220V inputs, depending on the model.
  4. Initial Power On: Flip the main power switch on the front panel to the 'ON' position. The LED display should illuminate.

7. Operating Instructions

7.1 Basic Voltage and Current Adjustment

The Sugon 3005PM offers continuously adjustable DC voltage from 0V to 30V and current from 0.001A to 5.1A.

Video 7.1: Demonstration of Voltage and Current Adjustment
  1. Power On: Ensure the device is powered on.
  2. Adjust Voltage: Use the 'Voltage Adjustment' knob to set the desired output voltage. The voltage display will show the current setting.
  3. Adjust Current: Use the 'Current Adjustment' knob to set the desired output current limit. The current display will show the current setting.
  4. Connect Load: Connect your device or circuit to the positive (+) and negative (-) output terminals.
  5. Monitor Output: The display will show the actual voltage, current, and power being delivered to the load.

7.2 USB Output Usage

The power supply features six adjustable USB outputs and two fixed 5V/2A USB outputs.

Sugon 3005PM charging a smartphone and battery, highlighting the 6 USB ports and adjustable 0V-30V output.
Figure 7.2: Using the USB Outputs
  1. Adjustable USB Outputs: These six ports can provide a voltage output from 0V to 30V, synchronized with the main terminal output. Connect your USB-powered device to one of these ports.
  2. Fixed 5V/2A USB Outputs (A & B): These two ports provide a stable 5V at 2A for standard USB charging.

7.3 Memory Functions (M1-M4)

The device allows you to store and recall up to four sets of voltage, current, and protection settings.

  1. Saving Settings: Set the desired voltage, current, and protection modes. Long-press one of the memory buttons (M1-M4) for three seconds until a confirmation beep or display change indicates the settings are saved.
  2. Recalling Settings: Short-press one of the memory buttons (M1-M4) for one second to instantly recall the stored settings.

7.4 Protection Settings

The Sugon 3005PM includes multiple protection features to safeguard the device and connected equipment.

  • Overvoltage Protection (OVP): Prevents output voltage from exceeding a set limit.
  • Overcurrent Protection (OCP): Prevents output current from exceeding a set limit. This can be set as 'Once OCP' (single trigger) or 'Continuous OCP' (sustained protection).
  • Overload Protection (OPP): Protects against excessive power draw.
  • High-Temperature Protection: Activates if the internal temperature exceeds safe limits, often engaging the cooling fan.

7.5 Display Brightness Adjustment

Image showing the display brightness adjustment process on the Sugon 3005PM.
Figure 7.3: Display Brightness Adjustment

To adjust the display brightness:

  1. Under normal use, long-press memory keys M1 and M2 simultaneously.
  2. The voltage position will display "0000", and the current display will show the current brightness level.
  3. Rotate the current knob to change the brightness.
  4. Once the appropriate brightness is set, press the current knob to save the brightness and exit the adjustment mode.

8. Maintenance

  • Cleaning: Regularly clean the exterior of the power supply with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Ventilation: Ensure the cooling fan and ventilation openings are free from dust and debris to maintain optimal performance and prevent overheating.
  • Fuse Replacement: If the device fails to power on, check the fuse located in the fuse box on the rear panel. Replace it with a fuse of the same type and rating if necessary.
  • Storage: When not in use for extended periods, store the power supply in a cool, dry place, away from direct sunlight and extreme temperatures.

9. Troubleshooting

  • No Power:
    • Check if the power cable is securely connected to both the device and the power outlet.
    • Verify the power outlet is functional.
    • Check and replace the fuse if blown.
  • No Output Voltage/Current:
    • Ensure the output terminals are correctly connected to the load.
    • Check if the voltage and current settings are above zero.
    • Verify that no protection mode (OVP, OCP, OPP) has been triggered. Reset if necessary.
  • Unstable Output:
    • Ensure the load is within the specified voltage and current limits of the power supply.
    • Check for loose connections.
    • Ensure adequate ventilation to prevent thermal instability.

10. User Tips

  • When working with sensitive electronics, always start with the lowest voltage and gradually increase it to the required level.
  • Utilize the memory functions (M1-M4) to quickly switch between frequently used voltage and current settings.
  • The device supports both AC110V-60Hz and AC220V-50Hz inputs, making it versatile for different regions. Always confirm your local voltage before connecting.

11. Warranty and Support

For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.