1. Product Overview
The SUSWE SU300 Series Variable Frequency Drive (VFD) is a high-performance vector universal frequency converter designed for precise motor speed control and energy efficiency. It features a compact design, easy installation, and robust protection functions, making it suitable for a wide range of industrial and commercial applications.

Key Features:
- Low repair rate due to high-quality imported parts.
- Reduced product volume for space-saving installation.
- Easy to install and wire.
- Strong parameter stability and user-friendly operation.
- High-function universal vector converter technology.
- Powerful radiator for efficient heat dissipation.
- Environmental protection features.
- Fast response and high control accuracy.
- Energy-saving capabilities.
- Simple and convenient wiring.
- Excellent stable frequency moment output.

2. Safety Information
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Ensure power is disconnected before any wiring or inspection.
The VFD unit may retain high voltage for up to 5 minutes after power is disconnected. Always wait for the "DANGER 5 min" indicator to clear before touching internal components.

3. Installation
3.1 Package Contents
- Frequency Converter x 1
- English Manual x 1
3.2 Mounting
The VFD supports guide rail one-button installation for convenient mounting.

3.3 Wiring
Refer to the following diagrams for proper electrical connections. Ensure all connections are secure and comply with local electrical codes.

Single-phase Power Supply: Connect L1 and L2 to the input reactor/wave filter. Output U, V, W connect to the motor. A braking resistance can be connected to PB terminals.
Three-phase Power Supply: Connect R, S, T to the input reactor/wave filter. Output U, V, W connect to the motor. A braking resistance can be connected to PB terminals.


For braking functionality, ensure the braking resistor is correctly installed and connected to the P+PB terminals.
4. Operation
4.1 Control Panel Overview
The VFD features a classic ergonomic control panel with clear labeling for easy operation.

- Display: Shows current operating parameters (e.g., frequency, current, voltage).
- PRG (Program): Enters/exits parameter setting mode.
- M-FUN (Multi-function Selection): Used for selecting various functions.
- Speed control knob: Adjusts the output frequency/motor speed.
- Decrement (Down Arrow): Decreases values or navigates menus.
- Increment (Up Arrow): Increases values or navigates menus.
- Shift (>>): Shifts cursor position during parameter editing.
- RUN: Starts motor operation.
- ENTER: Confirms selections or parameter changes.
- STOP/REST: Stops motor operation or resets faults.
4.2 Basic Operation Sequence
- Ensure all wiring is correct and secure.
- Turn on the main power switch to the VFD.
- Press the RUN key to start the operation of the converter and the connected motor.
- Turn the speed control knob to adjust the rotation speed of the motor.
- To slow down the motor, turn the speed control knob counter-clockwise.
- To stop the motor, press the STOP/REST button. The motor will decelerate slowly.
- Once the motor has stopped, pull down the main power switch to fully disconnect power.
4.3 Advanced Functions
The SU300 Series VFD offers several advanced functions for versatile control:
- Multi-segment operation: 16-segment programmable multi-speed control with multiple operation modes optional.
- Simple PLC operation: Up to 16 sections of speed can be set, with adjustable operation time for each section.
- RS485 communication: Multiple communication protocols can be selected with linkage synchronization control function.
- Output frequency range: Wide range, low frequency mode: 0-600Hz; High frequency mode: 0-3000Hz.
- PID control: Widely used in constant pressure water supply, wind pressure constant pressure control, and other applications.
- Built-in brake unit: The machine's built-in brake unit eliminates the need for a separately purchased unit (for 0.75KW-18.5KW models).

5. Maintenance
The VFD is designed for reliable operation with minimal maintenance. It features a silent fan for efficient cooling, which helps in reducing heat generation during operation.

Regularly inspect the VFD for dust accumulation, especially around the fan and heat sinks. Clean as necessary to ensure optimal cooling performance. Ensure proper ventilation around the unit.
6. Troubleshooting
The SU300 Series VFD incorporates several protection functions to ensure safe and stable operation. If an issue occurs, the VFD's display may show an error code or the motor may stop. Consult the full product manual for specific error codes and detailed troubleshooting steps.
Protection Functions:
- Overcurrent protection
- Overvoltage protection
- Undervoltage protection
- Overload protection
- Power module protection
- Overtemperature protection

7. Specifications
The SUSWE SU300 Series VFD is available in various power and voltage configurations. Please refer to the specific model for detailed parameters.
| Parameter | Description |
|---|---|
| Brand Name | SUSWE |
| Origin | Mainland China |
| Certification | CE, RoHS |
| Type | DC/AC Inverters (Frequency Converter) |
| Output Type | SINGLE (refers to single unit, not phase) |
| Output Frequency | 0.1-400Hz (Low frequency mode: 0-600Hz; High frequency mode: 0-3000Hz) |
| Input Voltage | 220V Single Phase or 380V 3 Phase |
| Output Voltage | 220V 3-Phase or 380V 3-Phase (matches input phase) |
| Output Power | 0.75KW (750W) to 5.5KW (5500W) |
| Weight | 1-1.5 KG (varies by model) |
| Dimensions (approx.) | 9.5 cm (W) x 18.0 cm (H) x 11.3 cm (D) |

Specific Model Example (SU300-0R75G2):
| Parameter | Value |
|---|---|
| Model | SU300-0R75G2 |
| Rated current | 4A |
| Adapted motor | 0.75KW 1Hp |
| Input voltage | Single phase 220V |
| Output voltage | Three phase 220V |
| External dimensions | 142 x 85 x 116.35 (mm) |
| Gross weight | 1Kg |

*Please refer to the product manual for detailed parameters of other models.
8. User Tips
- Phase Conversion: This VFD is designed to convert single-phase 220V input to three-phase 220V output, or to operate with three-phase 380V input and output. It is NOT designed to convert three-phase input to single-phase output.
- Motor Torque at Low Speeds: While VFDs allow for speed reduction, the motor's torque characteristics at very low speeds can vary. For applications requiring high torque at low RPMs, ensure your motor is suitable for VFD operation and consider additional cooling if necessary.
- RS485 Communication: The SU300 Series supports RS485 communication, allowing for integration into automated systems for remote control and monitoring. Refer to the detailed manual for programming and connection instructions.
- External Control Panel: If you require an external control panel for your SU300 frequency converter, ensure it is specifically designed for this series to guarantee compatibility and proper function.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your seller or the manufacturer directly. Keep your purchase receipt and product model details handy for faster assistance.