WinAPEX 268B

Contents

WinAPEX 268B Leakage Current Clamp Meter User Manual

Model: 268B | Brand: WinAPEX

1. Introduction

The WinAPEX 268B is a smart digital clamp meter designed for precise and safe electrical measurements. It features True RMS technology and can measure a wide range of parameters including AC/DC leakage current, AC/DC current, AC/DC voltage, resistance, capacitance, frequency, and temperature. Equipped with a clear, large LCD display with adjustable brightness and screen rotation, a Type-C rechargeable lithium battery, and Non-Contact Voltage (NCV) detection, this compact and portable device is ideal for both professional and home use.

Product demonstration video showcasing key features and measurements.

2. Safety Information

Always observe basic safety precautions when using this device to reduce the risk of fire, electric shock, or personal injury. Read all instructions carefully before use.

  • Ensure the device is in good working condition before each use.
  • Do not attempt to measure voltages or currents exceeding the specified maximum ratings.
  • Use appropriate personal protective equipment (PPE) such as insulated gloves and safety glasses.
  • Avoid using the meter in wet environments or during electrical storms.
  • Do not open the meter casing unless specifically instructed for battery replacement or calibration by qualified personnel.
  • Always disconnect power to the circuit before making resistance, capacitance, or diode measurements.
  • When measuring current with the clamp, ensure only one conductor is within the clamp jaw.

3. Package Contents

Verify that all items are present in your package:

  • 1 x WinAPEX 268B Clamp Meter
  • 1 x Pair of Test Leads (Red and Black)
  • 1 x User Manual (PDF available online: View PDF)
  • 1 x Thermocouple (for temperature measurement)
  • 1 x Type-C Charging Cable
  • 1 x Storage Bag
Package contents including clamp meter, test leads, USB cable, thermocouple, and storage bag.

Image: All items included in the WinAPEX 268B package.

4. Product Overview

Familiarize yourself with the components and controls of your WinAPEX 268B Clamp Meter.

Diagram of the clamp meter's operation interface, showing NCV sensing position, Jaw, Trigger, On/Off/Function Selection, Data retention/Backlight adjustment, Flashlight, Current switching button, Battery Compartment, Data return to zero/Flashlight button, Fire line discrimination/Induction power supply, and Socket.

Image: Front and back view of the WinAPEX 268B showing key operational parts.

  • Jaw: Used for clamping around conductors to measure current. Features a 22mm opening.
  • Trigger: Opens and closes the clamp jaw.
  • NCV Sensing Position: Area for non-contact voltage detection.
  • On/Off/Function Selection Button (Red): Powers the device on/off and cycles through measurement functions.
  • HOLD / Backlight Adjustment Button: Short press to hold the current reading; long press to adjust screen backlight brightness.
  • EF / LIVE Button: Activates Electric Field (NCV) detection or Live wire detection.
  • ZERO / Flashlight Button: Short press to zero the current reading (for DC current); long press to turn the flashlight on/off.
  • Current Switching Button: Toggles between AC and DC current measurement modes.
  • Battery Compartment: Houses the internal rechargeable battery.
  • Socket: Input terminals for test leads (COM, VΩ).

5. Setup

5.1 Initial Charging

The WinAPEX 268B is equipped with a built-in 3.7V 750mAh lithium battery. Before first use, or if the battery is low, charge the device using the provided Type-C USB cable.

  1. Connect the Type-C end of the charging cable to the meter's charging port.
  2. Connect the USB-A end to a standard USB power adapter (not included) or a computer USB port.
  3. The charging indicator on the meter will show charging status. A full charge provides approximately 20 hours of continuous use.
Clamp meter connected to a wall charger via Type-C cable, illustrating the charging process.

Image: Type-C charging port and battery specifications.

5.2 Brightness Adjustment

The LCD display brightness can be adjusted for optimal visibility in various environments.

  1. Turn on the meter.
  2. Long press the HOLD button (indicated by a sun icon) to enter brightness adjustment mode.
  3. Short press the HOLD button repeatedly to cycle through 5 levels of brightness.
  4. Release the button to set the desired brightness.

6. Operating Instructions

This section details how to perform various measurements with your WinAPEX 268B Clamp Meter.

6.1 Automatic Identification Mode

The meter can automatically identify AC voltage, DC voltage, resistance, and buzzer functions when test leads are connected.

  1. Connect the red test lead to the VΩ input and the black test lead to the COM input.
  2. Turn on the meter. It will automatically enter identification mode.
  3. Apply the test leads to the circuit or component. The meter will display the detected parameter (e.g., DC voltage, AC voltage, resistance, or continuity buzzer).
Demonstration of automatic identification for DC voltage, AC voltage, buzzer, and resistance measurements.

Image: Automatic identification of AC voltage, DC voltage, resistance, and buzzer.

6.2 AC/DC Current Measurement (Clamp)

Use the clamp jaw to measure AC or DC current without breaking the circuit.

  1. Turn on the meter.
  2. Press the function selection button until the current measurement mode (A~) or (A=) is selected.
  3. Press the current switching button to toggle between AC and DC current if needed.
  4. Open the clamp jaw using the trigger.
  5. Place only one conductor (live or neutral) inside the clamp jaw. Ensure the jaw is fully closed.
  6. Read the current value on the display.
Demonstration of current measurement using the clamp meter on a single wire.

Image: AC Current Measurement on a single wire.

6.3 AC/DC Leakage Current Detection

This meter is specifically designed to detect small leakage currents. For AC leakage, clamp both the neutral and live wires simultaneously.

  1. Turn on the meter.
  2. Select the appropriate AC or DC current range.
  3. For AC leakage current: Clamp both the neutral and live wires of the circuit at the same time. A normal clamp meter would show nothing, but this meter will display the leakage current (e.g., 2.3mA). If the display shows 0.00mA, it means there is no leakage.
  4. For DC leakage current: Clamp the DC circuit wires. The minimum measured current is 5mA. Close the pliers and press the "ZERO" key to reset before testing.
Demonstration of AC leakage current detection by clamping both neutral and live wires. Shows a reading of 2.3mA, indicating leakage.

Image: AC Leakage Current Detection. The pliers clamp the neutral and live wires at the same time. A reading of 2.3mA indicates leakage.

Demonstration of DC leakage current detection on a car engine, showing a reading of 00.30.

Image: DC Leakage Current Detection (6A~60A). Minimum measured: 5mA.

6.4 DC/AC Voltage Measurement

To measure voltage, use the test leads.

  1. Connect the red test lead to the VΩ input and the black test lead to the COM input.
  2. Turn on the meter and select the voltage measurement mode (V= for DC, V~ for AC). The automatic identification mode may also detect voltage.
  3. Connect the test leads in parallel to the circuit or component you wish to measure.
  4. Read the voltage value on the display.
Demonstration of DC Voltage and AC Voltage measurements using test leads.

Image: DC Voltage and AC Voltage measurements.

6.5 Resistance Measurement

To measure resistance, ensure the circuit is de-energized.

  1. Connect the red test lead to the VΩ input and the black test lead to the COM input.
  2. Turn on the meter and select the resistance measurement mode (Ω). The automatic identification mode may also detect resistance.
  3. Connect the test leads across the component to measure its resistance.
  4. Read the resistance value on the display.
Demonstration of Resistance measurement using test leads.

Image: Resistance measurement.

6.6 Capacitance Measurement

To measure capacitance, ensure the capacitor is discharged before testing.

  1. Connect the red test lead to the VΩ input and the black test lead to the COM input.
  2. Turn on the meter and select the capacitance measurement mode (nF, uF, mF).
  3. Connect the test leads across the capacitor terminals.
  4. Read the capacitance value on the display.
Demonstration of Capacitance measurement using test leads.

Image: Capacitance measurement.

6.7 Frequency Measurement

To measure frequency, use the test leads.

  1. Connect the red test lead to the VΩ input and the black test lead to the COM input.
  2. Turn on the meter and select the frequency measurement mode (Hz).
  3. Connect the test leads to the circuit where you want to measure frequency.
  4. Read the frequency value on the display.
Demonstration of Frequency measurement using test leads.

Image: Frequency measurement.

6.8 Temperature Measurement

Use the provided thermocouple for temperature measurements.

  1. Connect the thermocouple to the meter's input sockets (red to VΩ, black to COM).
  2. Turn on the meter and select the temperature measurement mode (°C/°F).
  3. Place the tip of the thermocouple on or near the object whose temperature you want to measure.
  4. Read the temperature value on the display.
Demonstration of Temperature measurement using the thermocouple.

Image: Temperature measurement.

6.9 NCV (Non-Contact Voltage) Test

The NCV function allows for quick detection of AC voltage without direct contact.

  1. Turn on the meter.
  2. Press the EF / LIVE button to activate NCV mode. The display will show 'EF'.
  3. Move the NCV sensing position of the meter close to an AC voltage source (e.g., a power outlet or live wire).
  4. If AC voltage is detected, the buzzer will sound continuously, and the LCD will display different segments according to the signal strength. If no signal is detected, it will show 'EF'.
Demonstration of NCV (Non-Contact Voltage) test near a power outlet. The display shows signal strength when voltage is detected, and 'EF' when no signal.

Image: NCV Non-contact Voltage Test. When AC voltage is nearby, the buzzer sounds continuously, and the LCD displays different segments according to the strength of the signal. 'EF' means no signal.

6.10 Live Wire Detection

This function helps identify live wires.

  1. Connect the red test lead to the VΩ input and the black test lead to the COM input.
  2. Turn on the meter.
  3. Press the EF / LIVE button to activate Live wire detection. The display will show 'LIVE'.
  4. Insert the red test lead into the suspected live terminal of an outlet or touch it to a wire.
  5. If a live wire is detected, the buzzer will sound and the screen will display "OL".

6.11 Diode and Continuity Test

Use these functions to check diodes and circuit continuity.

  1. Connect the red test lead to the VΩ input and the black test lead to the COM input.
  2. Turn on the meter and select the Diode/Continuity mode.
  3. For Diode Test: Connect the test leads across the diode. The display will show the forward voltage drop.
  4. For Continuity Test: Connect the test leads across the circuit or component. The buzzer will emit a long sound if the resistance is below a certain threshold (approximately 50Ω).
Demonstration of Diode and On/Off Beep (Continuity) tests.

Image: Diode and On/Off Beep (Continuity) measurements.

6.12 Screen Rotation

The display can be rotated for convenient viewing during operation, especially when using the clamp in awkward positions.

  1. During any measurement, long press the SELECT button.
  2. The screen display will rotate 180 degrees.
  3. Repeat the long press to rotate it back.
Image showing the clamp meter held in two different orientations, with the screen display rotating to match, for easy readability.

Image: Screen Rotation feature, allowing free operation with both hands.

6.13 Flashlight

The built-in flashlight assists in observing the environment and working in dimly lit areas.

  1. Long press the ZERO / Flashlight button.
  2. The flashlight will turn on.
  3. Long press again to turn it off.
Image showing the clamp meter's flashlight illuminating a dark area, highlighting its utility in low-light conditions.

Image: Flashlight feature for easy observation and work.

7. Specifications

Detailed technical specifications for the WinAPEX 268B Clamp Meter:

FunctionRangeAccuracyResolution
DC Voltage (DCV)6V/60V/600V/1000V±(0.5%+3) for 6V/60V/600V, ±(0.8%+10) for 1000V1mV/10mV/100mV/1V
AC Voltage (ACV) RMS6V/60V/600V/750V±(0.8%+3) for 6V/60V, ±(0.8%+3) for 600V, ±(1.2%+10) for 750V1mV/10mV/100mV/1V
DC Current (DCA) (clamp)6A/60A±(2.0%+5)1mA/10mA
AC Current (ACA) (clamp type)600mA/6A/60A±(2.0%+5)0.1mA/1mA/10mA
Resistance (Ω)600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ±(0.8%+3) for 600Ω to 6MΩ, ±(2.5%+15) for 60MΩ0.1Ω/1Ω/10Ω/100Ω/1kΩ/10kΩ
Capacitance (C)6nF/60nF/600nF/6uF/60uF/600uF/6mF/60mF±(3.5%+20) for 6nF to 600uF, ±(5.0%+20) for 6mF/60mF1pF to 10uF
Frequency measurement (Hz)6Hz/60Hz/600Hz/6kHz/60kHz/600kHz/6MHz/10MHz±(0.5%+5)0.001Hz to 10kHz
Temperature measurement (°C/°F)(-20-1000)°C / (0-1832)°F±(1.0%+5) < 400°C; ±(1.5%+15) ≥ 400°C
±(0.75%+5) < 750°F; ±(1.5%+15) ≥ 750°F
1°C / 1°F
Diode and on/off testSupportDiode forward voltage drop is about 1mA. Buzzer emits long sound when resistance value at two points is tested to be less than 50Ω.Open circuit voltage approximately 3V
Display TypeDigital Only
Operating Temperature0-40°C
Dimensions165mm x 68mm x 26mm
Weight400g
Jaw Size22mm
Battery IncludedNo (Internal rechargeable battery)
CertificationCE, RoHS
Detailed specifications table for Capacitance, Frequency, and Temperature measurements.

Image: Capacitance, Frequency, and Temperature measurement specifications.

Detailed specifications table for DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Diode, and On/Off Test.

Image: DCV, ACV, DCA, ACA, Resistance, Diode, and On/Off Test specifications.

Product dimensions: 165mm length, 68mm width, 26mm thickness.

Image: Product dimensions.

8. Maintenance

Proper maintenance ensures the longevity and accuracy of your clamp meter.

  • Cleaning: Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.
  • Storage: Store the meter in its protective bag in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: Recharge the battery regularly, even if not in frequent use, to maintain battery health. Avoid fully discharging the battery for extended periods.
  • Calibration: For professional applications requiring high accuracy, periodic calibration by a qualified service center is recommended.
  • Test Leads: Inspect test leads for any damage (cracks, frayed insulation) before each use. Replace damaged leads immediately.

9. Troubleshooting

If you encounter issues with your WinAPEX 268B, try the following:

  • Meter does not turn on: Ensure the battery is charged. Connect the Type-C charging cable and try again.
  • Inaccurate readings: Check that the correct measurement function is selected. Ensure test leads are properly connected and not damaged. For current measurements, verify only one conductor is within the clamp jaw.
  • Display shows 'OL' (Overload): The measured value exceeds the selected range. Switch to a higher range if available, or ensure the circuit is within the meter's capabilities.
  • Display shows 'EF' in NCV mode: This indicates no AC voltage signal is detected. Ensure the meter is close enough to a live AC source.
  • Buzzer not working for continuity: Check if the resistance is above the continuity threshold (approx. 50Ω).

10. User Tips

Enhance your experience with these practical tips:

  • Leakage Current Precision: This clamp meter is particularly effective for detecting small leakage currents (below 30mA for AC) which might not trip a differential circuit breaker but still indicate a fault.
  • Cable Compatibility: The 22mm jaw opening is comfortable for use with cables up to 25mm in section.
  • DC Current Measurement: The meter supports DC current measurement in mA, A, and 6A/60A ranges, making it versatile for various applications including automotive.
  • Screen Rotation for Convenience: Utilize the screen rotation feature when working in tight spaces or at awkward angles to always have a clear view of your readings.
  • Portability: Its lightweight and small size, along with the included storage bag, make it an excellent tool for on-the-go electrical work.

11. Warranty and Support

WinAPEX products are manufactured to high-quality standards. For any warranty claims or technical support, please contact your retailer or the official WinAPEX customer service. Keep your purchase receipt as proof of purchase.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.