1. Product Overview
The INKBIRD C216T Plug-in Timer Thermostat is a versatile device designed for precise temperature control. It supports three distinct operating modes: Temperature mode, Cycle Time mode, and Countdown mode. This product is ideal for intelligent temperature management in various settings, including heating systems, cultivation environments, seedling growth, wooden sheds, and general home use.

Figure 1: INKBIRD C216T Plug-in Timer Thermostat
Key Features:
- Three Control Modes: Temperature, Cycle Time, and Countdown.
- Wide Temperature Control Range: -40℉ to 212℉ (-40℃ to 100℃) with high accuracy.
- Automatic Heating/Cooling: Device starts and stops based on preset temperatures.
- Safety Features: High/low temperature alarms, child lock, and memory function.
- Advanced Functions: Refrigeration delay and temperature calibration.
- User-Friendly Display: Backlit LCD for clear visibility, even in low light.
- Flexible Timing: Four timing modes for precise scheduling.
- Durable Probe: IP67 waterproof temperature probe.
2. Package Contents
- 1x INKBIRD C216T Plug-in Timer Thermostat
- 1x Temperature Probe (2m/79in)
- 1x User Manual
3. Product Diagram

Figure 2: C216T Thermostat Components
- LCD with White Backlight
- Operational Buttons (MODE, UP, SET, DOWN)
- Output (max 10A 1200W(120Vac), 2200W(220 Vac))
- Temperature Probe (2m/79in)
- Input (100~240Vac 50/60Hz max 10A)
- Heating Icon
- Cooling Icon
- Timing Icon
- Child Lock Icon
- START: Start Temperature/Time
- STOP: Stop Temperature/Time
4. Setup
4.1 Initial Connection
- Insert the temperature probe (4) into its designated port on the thermostat.
- Plug the thermostat into a standard power outlet (Input 5).
- Plug your heating or cooling device into the thermostat's output socket (3).
The device is designed for plug-and-play operation. Upon power-on, the backlit LCD display (1) will illuminate, showing current temperature and default settings.
Video 1: Product demonstration showing plug-and-play setup and basic operation.
4.2 Memory Function
The C216T features a memory function. In case of a power failure, all your settings will be saved, and the device will resume operation with the last configured settings once power is restored. This eliminates the need to set it up again.
5. Operating Modes
The thermostat offers three primary control modes to suit various applications:

Figure 3: Three Control Modes Overview
5.1 Temperature Mode
This mode allows you to set a desired temperature range for heating or cooling. The device will automatically activate or deactivate the connected appliance to maintain the set temperature.

Figure 4: Heating and Cooling Operation
- Setting Temperature: Use the UP and DOWN buttons to adjust the START and STOP temperatures.
- High/Low Temperature Alarm: Set alarm thresholds. If the detected temperature exceeds these values, an alarm will sound. The buzzer can be muted.
- Refrigeration Delay: Prevents rapid cycling of cooling equipment, extending its lifespan. Adjustable from 0-10 minutes.
- Temperature Calibration: Allows fine-tuning of temperature readings to match a reference thermometer. Range: -8.8℉ to 8.8℉ (-4.9℃ to 4.9℃).

Figure 5: High/Low Temperature Alarm Function
5.2 Cycle Time Mode
This mode allows for cyclic operation of your connected device, turning it ON and OFF at set intervals. This is useful for applications requiring periodic activation, such as irrigation or ventilation.

Figure 6: Flexible Timing Functions
- P01 Cycle Time: Set a specific ON duration and OFF duration for continuous cycling.
5.3 Countdown Mode
The Countdown mode provides precise control over device activation or deactivation after a set period.
- P02 Countdown ON: The device will turn ON after a specified countdown period.
- P03 Countdown OFF: The device will turn OFF after a specified countdown period.
- P04 Countdown ON & OFF: The device will turn ON after a first countdown, and then turn OFF after a second countdown.
Maximum timing range for all countdown functions is 99 hours and 59 minutes.
6. Advanced Features
6.1 Backlit LCD Display
The large LCD screen with white backlight ensures that temperature and settings are easily readable, even in dark environments.

Figure 7: Backlit LCD and Calibration/Delay
6.2 Child Lock
To prevent accidental changes to settings, the thermostat includes a child lock feature. When activated, the operational buttons are locked, preventing misoperation.

Figure 8: Child Lock and Other Features
6.3 Factory Reset
If you need to revert all settings to their default factory values, a factory reset option is available. Refer to the detailed instructions in the included user manual for the specific button combination to perform this action.
7. Maintenance
- Cleaning: Wipe the thermostat and probe with a soft, dry cloth. Do not use abrasive cleaners or immerse the main unit in water.
- Probe Care: Ensure the temperature probe is clean and free from debris for accurate readings. While the probe is IP67 waterproof, avoid unnecessary exposure to harsh chemicals.
- Storage: Store the device in a cool, dry place when not in use.
8. Troubleshooting
- No Display/Power: Ensure the thermostat is securely plugged into a working power outlet. Check the power outlet with another device.
- Inaccurate Temperature Reading: Verify the temperature probe is correctly inserted and clean. Perform a temperature calibration if necessary (refer to section 5.1).
- Device Not Responding to Settings: Check if the child lock is activated (look for the lock icon on the display). If so, unlock it. Ensure the correct operating mode is selected.
- Alarm Constantly Triggering: Review your high/low temperature alarm settings. Adjust them to an appropriate range for your application.
- Timing Issues: Double-check the set ON/OFF times or countdown durations in Cycle Time or Countdown modes.
9. Specifications
| Attribute | Value |
|---|---|
| Model | C216T Temperature Controller |
| Brand Name | INKBIRD |
| Origin | Mainland China |
| Use | Household |
| Certification | CE, FCC |
| Display Size | 1.9 Inches & Under |
| Input | 100-240Vac 50/60Hz max 10A |
| Output | 100-240Vac 50/60Hz max 10A 1200W(120Vac), 2200W(220 Vac) |
| Temperature Control Range | -40℉-212℉/-40℃-100℃ |
| Temperature Display Accuracy | 0.1℉/℃ |
| Temperature Measurement Error | ±2.0℉/±1.0℃ |
| Refrigeration Delay Time | 0-10 minutes |
| Temperature Calibration Range | -8.8℉-8.8℉/-4.9℃-4.9℃ |
| Maximum Timing Range | 99 hour and 59 minutes |
| Time Error | ±2 seconds per day |
| Operating Temperature | Room temperature |
| Storage Temperature | 32℉-140℉/0℃-60℃ |
| Storage Humidity | 20%RH-80%RH (non-condensing) |
| Battery Included | No |
| High-concerned chemical | None |
| Is Smart Device | No |
10. User Tips
- For critical applications, always use a secondary thermometer to verify the C216T's readings, especially after initial setup or calibration.
- When using the Cycle Time mode, consider the warm-up or cool-down time of your connected appliance to ensure optimal performance.
- Utilize the child lock feature in environments where settings might be accidentally altered, such as in homes with children or pets.
- Regularly check the temperature probe for any signs of damage or wear, as this can affect accuracy.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official INKBIRD website or contact their customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.