1. Introduction

This manual provides essential information for the installation, operation, and maintenance of your SUMRY HGS Off Grid Solar Inverter. The HGS series is a multi-functional inverter/charger combining functions of inverter, solar charger, and battery charger to offer uninterruptible power support in a portable size. Its comprehensive LCD display allows user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

The SUMRY HGS Off Grid Solar Inverter is designed to provide reliable power for various household appliances and can operate with or without batteries, making it a versatile solution for your energy needs.

2. Key Features

  • Pure sine wave output for sensitive electronics.
  • Output power factor 1.0.
  • Programmable supply priority for PV, battery, or grid.
  • User-adjustable charge current and voltage.
  • Wide PV input range (120VDC-500VDC) with 110A MPPT solar charge controller.
  • Capable of working without batteries on sunny days.
  • Optional WiFi Monitoring Function for remote access.
  • Optional anti-dusk kit for harsh environments.
  • Optional LCD remote control with a 10-meter wire.
  • PV and electricity complementary functionality.
  • Compatible with various battery types including lithium, LiFePO4, and Gel batteries.
  • Integrated protections: Overload, Overheating, High/Low Voltage, Battery, Short Circuit, Overcurrent, Anti-Reverse, and Power Failure Protection.
Diagram illustrating key features of the SUMRY HGS inverter including battery-less operation, wide PV voltage, MPPT charging, and optional WiFi/remote display.
Figure 2.1: Key Features of the HGS Inverter.

3. Product Overview

The SUMRY HGS inverter features a user-friendly design with clearly labeled components for easy operation and monitoring.

Diagram showing the front and bottom panels of the SUMRY HGS inverter with numbered labels for each component.
Figure 3.1: Product Overview - Front and Bottom Panels.

Component Identification:

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on/off switch
  7. AC input
  8. AC output
  9. PV input
  10. Battery input
  11. Circuit breaker
  12. RS485/RS232 communication port

4. Specifications

The SUMRY HGS series offers models with different power ratings and battery voltages to suit various applications.

Table detailing product parameters for HGS 3500W and HGS 5500W models, including rated power, PV array power, surge power, charging current, battery voltage, MPPT range, efficiency, dimensions, and net weight.
Figure 4.1: Product Parameters for HGS 3500W and HGS 5500W.
Table 4.1: General Specifications
AttributeHGS 3500WHGS 5500W
Rated Power3500VA/3500W5500VA/5500W
MAX.PV Array Power5000W6000W
Surge Power7000VA11000VA
MAX.Charging Current110A110A
Battery Voltage24V48V
MPPT Range @Operating Voltage120-500VDC120-500VDC
MAX. Efficiency98%98%
Dimension (D*W*H)472*298*129mm472*298*129mm
Net Weight9.5kg10.5kg

Additional Specifications:

  • Output Power: 1 - 200 KW
  • Output Type: SINGLE
  • Output Frequency: 50Hz/60Hz
  • Certification: CE
  • Input Voltage: 220/230/240VAC
  • Frequency Range: 50/60Hz AUTO sensing
  • Work without battery: Yes

Note: Ensure the power rating is higher than the appliance you want to apply. You should purchase a larger model (at least 10% to 20% more than the maximum load). If you want to run more than one appliance at the same time, refer to the total wattage. To run inductive loads for a long time, a pure sine wave inverter is recommended.

5. Setup

5.1 Mounting the Unit

Consider the following points before selecting where to install the inverter:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install the inverter at eye level in order to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Diagram showing mounting clearances for the inverter: 20cm to sides, 50cm above and below.
Figure 5.1: Mounting the Unit with Recommended Clearances.

5.2 Battery Connection

Proper battery connection is crucial for the safe and efficient operation of your inverter. Please follow these steps and refer to the recommended cable and terminal sizes.

Table showing recommended battery cable and terminal sizes for 3.5KW 24V and 5.5KW 48V models, including typical amperage, battery capacity, wire size, ring terminal dimensions, and torque value.
Figure 5.2: Recommended Battery Cable and Terminal Size.

Connection Steps:

  1. Assemble battery ring terminal based on recommended battery cable and terminal size.
  2. Connect all battery packs as units require.

NOTE: Please only use sealed lead acid battery or sealed GEL/AGM lead-acid battery.

5.3 System Diagram

The following diagrams illustrate typical solar system connections for the HGS inverter, both with and without AC power availability.

System connection diagram for an off-grid solar inverter, showing solar modules, inverter, generator, utility grid, battery packs, and home appliances connected via air switches.
Figure 5.3: Solar System Connection Diagram.
System diagram showing inverter operation with battery connected, both when solar power and AC power are available, and when only solar power is available.
Figure 5.4: System Diagram - Operation with Battery Connected.

6. Operating Instructions

6.1 Operation and Display Panel

The inverter features an intuitive display panel with LED indicators and function keys to monitor status and configure settings.

Diagram of the inverter's operation and display panel, showing the LCD display, LED indicators, and function keys.
Figure 6.1: Operation and Display Panel.
Table 6.1: LED Indicator Messages
LED IndicatorMessages
AC / INV (Green Solid On)Output is powered by utility in Line mode.
AC / INV (Green Flashing)Output is powered by battery or PV in battery mode.
CHG (Green Solid On)Battery is fully charged.
CHG (Green Flashing)Battery is charging.
FAULT (Red Solid On)Fault occurs in the inverter.
FAULT (Red Flashing)Warning condition occurs in the inverter.
Table 6.2: Function Keys Description
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

6.2 LCD Function Description

The LCD provides detailed information about the inverter's status and operation through various icons and numerical readings.

Detailed diagram of the LCD display with numbered labels explaining each icon and reading, such as PV input, AC input, voltage, frequency, load level, battery level, and various operational statuses.
Figure 6.2: LCD Function Description.
  1. PV input
  2. AC input
  3. Input voltage, input frequency, PV voltage, battery voltage, charger current
  4. Setting programs
  5. Flashing with warning code, Lighting with fault code
  6. Output voltage, output frequency, load percent, load in VA, load in watt and discharging current
  7. Load level
  8. DC/AC inverter circuit is working
  9. Battery level
  10. Utility charger circuit is working
  11. Unit connects to the PV panel
  12. Unit connects to the mains
  13. Load is supplied by utility power
  14. Unit alarm is disabled
  15. Overload

6.3 Wi-Fi Monitoring (Optional)

For enhanced monitoring and control, the inverter supports Wi-Fi connectivity. You can download the SmartESS app for iOS and Android devices to monitor your system remotely.

Image showing the SUMRY HGS inverter with a Wi-Fi module and QR codes for downloading the SmartESS app for iOS and Android.
Figure 6.3: Wi-Fi Monitoring with SmartESS App.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your SUMRY HGS inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris to prevent overheating.
  • Connection Checks: Regularly inspect all electrical connections (PV, battery, AC input/output) to ensure they are tight and free from corrosion. Loose connections can lead to poor performance or safety hazards.
  • Ventilation: Ensure that the inverter's installation area maintains the recommended clearances for proper airflow. Blocked vents can cause the unit to overheat and shut down.
  • Battery Health: If using batteries, monitor their health and charge status as recommended by the battery manufacturer. Ensure they are compatible with the inverter's charging parameters.

8. Troubleshooting

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For specific fault codes, consult the LCD Function Description and LED Indicator Messages.

  • No Power Output: Check all input power sources (PV, AC grid, battery) and ensure they are connected and supplying power. Verify the circuit breaker is not tripped.
  • Inverter Not Turning On: Ensure the power on/off switch is in the 'ON' position. Check battery voltage to ensure it's within the operating range.
  • Fault Indicator On/Flashing: Refer to Table 6.1 for LED indicator messages to identify the type of fault or warning. This may indicate an overload, overheating, or voltage issue.
  • Overload Protection: If an overload occurs, the inverter may shut down. Reduce the connected load and restart the inverter. Ensure total load does not exceed the inverter's rated power.
  • Overheating: If the inverter is hot, check for blocked ventilation and ensure adequate clearance around the unit. Allow it to cool down before restarting.
  • Battery Not Charging: Verify PV input and AC input connections. Check the charging indicator LED. Ensure battery settings are correctly configured.

If the problem persists after following these steps, please contact customer support.

9. User Tips

  • The SUMRY HGS inverter is capable of operating without batteries, especially beneficial on sunny days when direct solar power can be used to run loads.

10. Warranty and Support

Your SUMRY HGS Off Grid Solar Inverter comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and ensures reliable operation under normal use conditions.

For any technical assistance, installation queries, or troubleshooting support, our professional engineer team is available to help you. Please contact our customer support for pre-sale and after-sale service.

Image detailing warranty and service information, including 1-year warranty and professional engineer support.
Figure 10.1: Warranty & Service Information.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.