KKMOON KKM828

Contents

KKM828 Intelligent Graphical Oscilloscope Multimeter

Model: KKM828 | Brand: KKMOON

User Manual

1. Introduction

The KKM828 is a versatile 2-in-1 intelligent graphical oscilloscope multimeter designed for efficient and accurate electrical measurements. This device combines the functionality of a digital multimeter with a graphical oscilloscope, featuring a 2.4-inch color screen for clear waveform display and data analysis. Made from fine quality materials, it is practical, easy to operate, and suitable for a wide range of applications.

2. Package Contents

Please check the package contents upon unboxing to ensure all items are present:

  • 1 x KKM828 Graphical Multimeter
  • 1 x Pair of Test Pens
  • 1 x Protective Bag
  • 1 x User Manual (this document)

3. Product Overview

The KKM828 features a compact design with a clear color display and intuitive controls.

KKM828 Oscilloscope Multimeter main view with kickstand

Figure 3.1: KKM828 Intelligent Graphical Oscilloscope Multimeter with integrated kickstand.

Key Features:

  • 2.4-inch Color Screen: Provides a clearer display for measurements and waveforms. The secondary display at the bottom offers additional function menus.
  • Function Dial: A sensitive pressing function dial allows for accurate gear selection between different measurement modes.
  • Silicone Buttons: Responsive buttons (F1, F2, F3, F4, R, S) for navigating menus and controlling functions.
  • Back Bracket: The integrated back bracket can be tilted at 60° for convenient viewing during operation.
  • Test Lead Ports: Clearly labeled ports for 10A, mA/uAmF, VΩCap, and COM connections.
Detailed view of KKM828 screen, function dial, and back bracket

Figure 3.2: Detailed view highlighting the screen, function dial, and back bracket for easy reading.

4. Setup

4.1. Battery Installation

  1. Locate the battery compartment on the back of the KKM828.
  2. Open the battery compartment cover.
  3. Insert 3 x AA batteries (not included) into the compartment, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.

Note: Ensure the device is OFF before installing or replacing batteries.

5. Operating Modes

5.1. Multimeter Functions

The KKM828 offers a comprehensive range of multimeter measurement functions. Rotate the central dial to select the desired measurement type.

KKM828 performing Frequency, Duty Cycle, Diode Test, and Continuity Test

Figure 5.1: Examples of multimeter functions including Frequency, Duty Cycle, Diode Test, and Continuity Test.

  • AC/DC Voltage: Measure voltage by connecting test leads to the appropriate VΩCap and COM ports.
  • AC/DC Current: Measure current by connecting test leads to the 10A or mA/uAmF and COM ports, depending on the expected current range.
  • Resistance: Measure resistance by connecting test leads to the VΩCap and COM ports.
  • Capacitance: Measure capacitance by connecting test leads to the VΩCap and COM ports.
  • Frequency: Measure frequency by connecting test leads to the VΩCap and COM ports.
  • Duty Cycle: Measure duty cycle by connecting test leads to the VΩCap and COM ports.
  • Diode Test: Test diodes by connecting test leads to the VΩCap and COM ports.
  • Continuity Test: Check for circuit continuity by connecting test leads to the VΩCap and COM ports. An audible beep indicates continuity (<50Ω).

5.2. Oscilloscope Functions

The KKM828 integrates an oscilloscope for waveform analysis. To enter oscilloscope mode, long-press the 'R' button (often labeled F1 or R on the dial). The device can measure waveforms directly without a dedicated oscilloscope probe.

KKM828 in oscilloscope mode with test leads connected

Figure 5.2: KKM828 displaying a waveform in oscilloscope mode. Long press 'R' to enter this mode.

Trigger Modes:

The oscilloscope function supports three different trigger modes to suit various user needs:

  • AUTO Mode: No trigger signal detected; acquires waveform data continuously.
  • NORMAL Mode: Trigger signal detected; acquires waveform data when a stable trigger condition is met.
  • SINGLE Mode: Trigger signal detected; acquires a single waveform data capture when the trigger condition is met.
KKM828 oscilloscope parameter setting with Auto, Normal, and Single trigger modes illustrated

Figure 5.3: Illustration of the three trigger modes available for the oscilloscope function.

Waveform Display:

The 2.4-inch color screen provides a clear graphical representation of waveforms, including parameters such as VP-P (Peak-to-Peak Voltage), average value, effective value (RMS), frequency, time base, and amplitude.

Examples of various waveforms displayed on the KKM828 screen

Figure 5.4: Examples of different waveform types displayed on the KKM828's color screen.

6. Specifications

General Specifications:

  • Material: ABS
  • Color: Black
  • Display: 320*240 LCM, approx. 2.4 inches
  • Backlit: White
  • Input Resistance: 10MΩ
  • Battery: 3 * AA battery (not included)
  • Power Consumption: Approx. 80mA
  • Use Time (low light): Approx. 5 hours
  • Storage: 100 data / 10 waveforms
  • Use Environment: 0~40℃, <75%RH
  • Storage Environment: -10~60℃, <90%RH
  • Bandwidth: ACV/1MHz, ACA/5KHz
  • Max. Real-time Sampling Rate: 2.5Msps
  • Multimeter Measurement: Automatic range + Manual range
  • Oscilloscope Function Secondary Display: VP-P, average value, effective value, frequency, time base, amplitude
  • Measurement Mode: Normal, Automatic
  • Item Size: 160 * 83 * 32mm / 6.3 * 3.3 * 1.3in
  • Item Weight: 195g / 6.9ounce

Multimeter Specifications:

Measurement Type Range Uncertainty
DC Voltage 400mV/4V/40V/400V/1000V 0.75% rdg+10dgt
AC Voltage 400mV/4V/40V/400V/750V 1.0% rdg+10dgt
DC Current 40mA/400mA/4A/10A 1.2% rdg+10dgt
AC Current 40mA/400mA/4A/10A 1.5% rdg+10dgt
Resistance 400.0Ω~40.00MΩ 1.0% rdg+5dgt
Capacitance 0.1nF~100, 10.00mF 2.0% rdg+10dgt
Frequency 5Hz~10MHz 1.0% rdg+5dgt
Duty Cycle 0.1%~99.9% 1.0% rdg+5dgt
Diode Test Voltage approx. 5V, current approx. 1.5mA N/A
Continuity Test Judgment resistance: <50Ω (beep) N/A

Fuse Specifications: 500mA/250V, 10A/250V

7. Safety Warnings

To ensure safe operation and prevent damage to the device or injury, please observe the following safety precautions:

  • Double Insurance Tube: The device is equipped with double insurance tubes (500mA/250V and 10A/250V) for enhanced safety. Do not bypass or use incorrect fuses.
  • Input Voltage Warning: If the input voltage exceeds 24V, the device will emit a beep warning. Exercise caution when measuring high voltages.
  • Input Over Range Warning: An audible beep warning will sound if the input measurement exceeds the selected range. Adjust the range or disconnect the test leads immediately.
  • Always ensure the test leads are correctly connected to the appropriate ports for the measurement being performed.
  • Do not attempt to measure circuits with voltages or currents exceeding the device's maximum ratings.
  • Do not operate the device if it appears damaged or if the battery compartment is not securely closed.
  • Avoid using the device in wet environments or with wet hands.

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: When not in use for extended periods, remove the batteries to prevent leakage. Store the device in its protective bag in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Fuse Replacement: If a fuse blows, replace it only with a fuse of the same type and rating as specified in the specifications section.

9. Troubleshooting

  • Device does not power on: Check if the batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
  • Inaccurate readings: Ensure test leads are properly connected and not damaged. Verify the correct measurement function and range are selected.
  • No waveform displayed in oscilloscope mode: Check if the 'R' button was long-pressed to enter oscilloscope mode. Ensure the input signal is within the device's bandwidth and amplitude limits. Adjust trigger settings if necessary.
  • Beeping sound during measurement: This indicates either an input voltage greater than 24V or an over-range condition. Disconnect immediately and re-evaluate your measurement setup.

10. User Tips

  • Always refer to this user manual for detailed instructions on specific functions and safety guidelines.
  • For critical measurements, perform a quick check on a known good circuit to verify the device's functionality.
  • Utilize the back bracket for hands-free operation and improved visibility during prolonged use.
  • Take advantage of the data storage feature to record and review up to 100 data points and 10 waveforms for later analysis.

11. Warranty and Support

For any issues not covered in this manual or for technical support, please contact the seller or manufacturer. Keep your purchase receipt as proof of purchase for warranty claims.

© 2024 KKMOON. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.