1. Product Overview
The ASAIR AFM3000 is a highly accurate mass air flow sensor designed for precise bidirectional measurement of gas flow. It features a low pressure drop design, fast response time, and is fully calibrated and temperature compensated before delivery, ensuring minimal zero-point deviation. This sensor offers flexible output options, including digital I²C and analog 1-5V, making it suitable for a wide range of applications.
Key Features:
- Low pressure drop design
- Bilateral measurement with high data accuracy
- Fast response time
- Fully calibrated and temperature compensated
- Small deviation of zero point
- 5V power supply
- Digital I²C and Analog 1-5V output options
Applications:
The AFM3000 sensor can be widely used in various fields, including:
- Medical equipment (e.g., Ventilators, Anesthesia Machines)
- Environmental monitoring systems
- Laboratory instruments
- Process automation
- Burner control
- Fuel cell control
- Other gas flow measurement applications
Video: Overview of the AFM3000 Gas Flow Meter, highlighting its features and applications.
2. Setup and Installation
Proper installation is crucial for the accurate operation of the AFM3000 sensor. Please follow these guidelines:
2.1 Physical Installation
- Mounting: The sensor is designed for inline installation within a gas flow path. Ensure the sensor is securely mounted to prevent vibrations or movement that could affect readings.
- Flow Direction: Observe the arrow marking on the sensor body, if present, to align with the intended gas flow direction. The AFM3000 supports bidirectional measurement, but correct orientation can be important for consistent readings or specific application requirements.
- Connection: Ensure the gas inlet and outlet are properly sealed to prevent leaks.

Image: Side view of the AFM3000 sensor, showing the product label and indicating the general flow path.
2.2 Electrical Connection
The AFM3000 sensor requires a 5V DC power supply and offers either I²C digital output or 1-5V analog output. Refer to the interface definition below for correct wiring.

Image: Detailed diagram illustrating the AFM3000 sensor's interface and pin definitions.
AFM3000 Pinout:
| Pin | Name | Description |
|---|---|---|
| 1 | SDA | I²C Data Line |
| 2 | GND | Ground |
| 3 | VDD | Power Supply (5V DC) |
| 4 | SCL | I²C Clock Line |
Note: Ensure all connections are secure and correctly polarized to prevent damage to the sensor or connected equipment.
3. Operating Instructions
Once installed and powered, the AFM3000 sensor will begin measuring gas flow. The output signal will correspond to the measured flow rate within its specified range.
- Power On: Apply 5V DC power to the VDD and GND pins.
- Output Reading:
- For I²C digital output: Interface with a microcontroller or data acquisition system using the SDA and SCL lines to read digital flow data.
- For 1-5V analog output: Connect the analog output pin (if configured for analog output) to an analog-to-digital converter (ADC) or a system that can read voltage signals. The voltage will vary proportionally to the gas flow rate. - Bidirectional Measurement: The sensor is capable of measuring flow in both directions (-200 SLM to +200 SLM). The output signal will indicate both the magnitude and direction of the flow. Consult the sensor's datasheet for specific details on how the output signal differentiates flow direction (e.g., positive voltage for one direction, negative or a specific range for the other).
4. Maintenance
The AFM3000 sensor is designed for reliable operation with minimal maintenance. However, adhering to general care practices can prolong its lifespan and ensure continued accuracy:
- Cleaning: Keep the sensor's flow path and external surfaces clean and free from dust, debris, or corrosive substances. Avoid using harsh chemicals for cleaning.
- Environmental Conditions: Operate and store the sensor within the specified temperature and pressure ranges to prevent damage.
- Inspection: Periodically inspect the sensor for any signs of physical damage or wear.
5. Troubleshooting
If you encounter issues with your AFM3000 sensor, consider the following:
- No Output/Incorrect Readings:
- Verify the 5V DC power supply is stable and correctly connected.
- Check all wiring connections (VDD, GND, SDA, SCL/Analog Out) for looseness or incorrect polarity.
- Ensure the sensor is installed correctly in the gas flow path and that there are no blockages or leaks. - Inconsistent Readings:
- Check for any external factors that might be affecting the gas flow, such as pressure fluctuations or temperature changes outside the operating range.
- Ensure the gas being measured is compatible with the sensor's specifications. - Communication Issues (I²C):
- Confirm the I²C address is correctly configured in your microcontroller or system.
- Check for proper pull-up resistors on the SDA and SCL lines.
For persistent or complex issues, please contact your vendor or the manufacturer's technical support.
6. Specifications
The following table details the technical specifications for the ASAIR AFM3000 Gas Air Flow Sensor:
| Parameter | Value |
|---|---|
| Model No. | AFM3000 |
| Supply Voltage | 5V DC |
| Measuring Range | -200 ~ +200 SLM |
| Operating Temperature | 0 ~ +50°C |
| Storage Temperature | 0 ~ +50°C |
| Accuracy | ±1.5% (typical) |
| Response Time | 10 ms |
| Sampling Period | 10 ms |
| Power Consumption | <10 mW (power consumption) |
| Pressure Loss | <10 Pa (at 200 SLM) |
| Operating Pressure Range | 0.7 ~ 1.3 bar |
| Output Type | Digital (I²C) / Analog (1-5V) |
| Material | Polymer |
| Origin | Mainland China |
| Original Manufacturer | Guangzhou Aosong |
7. Warranty and Support