Gaqqee DDS6619

Contents

DDS6619 Din Rail Single Phase Energy Meter User Manual

Model: DDS6619 | Brand: Gaqqee

1. Introduction

The Gaqqee DDS6619 is a DIN rail single-phase electronic energy meter designed for measuring active energy consumption. It incorporates the latest microelectronic technology, imported special large-scale integrated circuits, advanced digital sampling technology, and SMT technology to ensure high reliability, small size, light weight, and a modern appearance. This meter is suitable for measuring energy consumption with a rated frequency of 50Hz or 60Hz.

Key Features:

  • High-quality materials for guaranteed performance.
  • New type of single-phase fully electronic energy meter.
  • Utilizes microelectronic, digital sampling, and SMT technologies.
  • Offers good reliability, compact size, and lightweight design.
  • Measures active energy consumption at 50Hz or 60Hz.
  • LCD backlight display for clear readings.
  • Displays temporary (resettable) and total (non-resettable) power consumption.
  • Capable of displaying voltage, current, power, frequency, and power factor.

2. Specifications

AttributeValue
Model NumberDDS6619
Brand NameGaqqee
Dimensions7.8 x 6.6 x 3.6 cm
Operating Temperature-10 to 50°C
Rated Voltage220V AC
Output Voltage230V AC
Max Operating Current80A
Accuracy Class1
Measuring Energy Range0 to 99999.9 kWh
PhaseSingle phase
Power SupplyAC
Display TypeDigital Only, LCD with Backlight
Pulse Frequency1000imp / kWh
CertificationCE
Dimensional drawing of the DDS6619 energy meter and a side view showing the quality certificate.

Figure 2.1: Dimensions and Quality Certificate

3. Setup and Installation

Proper installation is crucial for the safe and accurate operation of the DDS6619 energy meter. Please read these instructions carefully before proceeding.

3.1 Pre-Installation Checks

  • The meter should be installed and used only after being tested and sealed. If the seals are broken or the meter has been stored for an extended period, it must be retested before use.
  • Inspect the original packaging and the meter cover for any damage. Do not install a damaged meter.
  • Installation should only be performed by experienced electricians or professional technicians who have thoroughly read this user manual.

3.2 Installation Environment

  • Install the meter in a well-ventilated and dry location.
  • The mounting surface (bottom plate) must be fire-resistant and stable, not prone to shaking.
  • In dusty environments, the instrument must be installed within a protective box to prevent mechanical damage.
  • Consider measures to protect against lightning damage in areas prone to thunderstorms.

3.3 Wiring Instructions

  • Ensure all wiring conforms to the wiring diagram provided on the meter's casing or in this instruction manual.
  • It is highly recommended to use soft copper wire for input connections to prevent loose contacts, which could lead to overheating and damage to the meter.
  • After correct connection to the power grid, the meter's power indicator should illuminate, confirming proper power supply.
  • The meter's load capacity is between 0.05Ib and Imax (80A). Exceeding this capacity can result in inaccurate readings or damage to the current coil.
Wiring diagram for the DDS6619 energy meter, showing connections between a power switch, the energy meter, and an air circuit breaker for a single-phase 2-wire setup (L and N lines).

Figure 3.1: Wiring Diagram

Side view of the DDS6619 energy meter, highlighting the DIN rail mounting clip.

Figure 3.2: DIN Rail Mounting Clip

4. Operation

4.1 Display Functions

The DDS6619 meter features a 5+1 bit LCD backlight display, capable of showing up to 99999.9 kWh. The display has two rows:

  • Top Row: Temporary Power Consumption (Resettable) - This value can be reset to zero.
  • Bottom Row: Total Power Consumption (Non-Resettable) - This value accumulates and cannot be reset.

The meter can cycle through various parameters including power consumption (kWh), voltage (V), current (A), power (W), frequency (Hz), and power factor (PF).

Front view of the DDS6619 energy meter showing the LCD display with temporary and total kWh readings, along with examples of voltage, current, power, frequency, and power factor displays.

Figure 4.1: Meter Display Overview

4.2 Button Functions

The meter features a single button, typically labeled 'RESET' or indicated by an arrow symbol, for controlling display and reset functions:

  • Backlight Awakening: The backlight will awaken automatically or by pressing the button.
  • Switching Parameters: Click the button to cycle through and display different parameters (kWh, V, A, W, Hz, PF).
  • Resetting Temporary Power Consumption: To reset the temporary power consumption (top row) to zero, press and hold the button for 3 to 5 seconds (or 6 seconds as indicated in some diagrams). The total power consumption (bottom row) cannot be reset.
Close-up of the meter's display and button, illustrating how to reset temporary power consumption by holding for 6 seconds, and how to switch parameters with a click. It also shows the 5+1 bit backlight display.

Figure 4.2: Display and Reset Instructions

4.3 Indicators

  • Pulse Indication: When the meter is actively consuming electric energy, the pulse indicator light will flash (approximately 80ms per flash).
  • Reverse Indication: If the load connected to the meter is using energy in reverse, the reverse indicator light will illuminate.
Play video
Watch video online

Video 4.1: Demonstration of DDS6619 Display Functions

This video illustrates the various parameters displayed by the energy meter and the functionality of the reset button.

5. Maintenance

The DDS6619 energy meter is designed for long-term, reliable operation with minimal maintenance. To ensure its longevity and accuracy:

  • Keep Clean: Regularly clean the meter's exterior with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • Environmental Protection: Ensure the meter remains in a ventilated and dry environment. If installed in a dusty area, verify that its protective box is intact and sealed to prevent dust ingress and mechanical damage.
  • Avoid Physical Impact: Protect the meter from strong vibrations or physical shocks.
  • Regular Checks: Periodically check the wiring connections to ensure they remain tight and secure, especially if soft copper wire was used as recommended.

6. Troubleshooting

This section provides guidance on common issues you might encounter with your DDS6619 energy meter.

Common Issues and Solutions:

  • Meter Not Powering On / Display Blank:
    • Check the power supply to the meter.
    • Verify all wiring connections are correct and secure according to the wiring diagram (Figure 3.1).
    • Ensure the power switch and air circuit breaker are in the ON position.
  • Inaccurate Readings or Meter Malfunction:
    • Confirm that the load connected to the meter does not exceed its maximum operating current of 80A. Overloading can lead to inaccurate readings or damage.
    • Check for loose wiring connections, which can affect accuracy.
    • If the meter was not sealed or stored for a long time before installation, it might require retesting.
  • Pulse Indicator Not Flashing:
    • Ensure there is an active electrical load connected and drawing power through the meter.
    • Verify the meter is correctly wired and receiving power.
  • Reverse Indicator Light On Continuously:
    • This indicates energy is flowing in the reverse direction. Check your wiring to ensure correct polarity and direction of current flow.

If you encounter issues not covered here or if troubleshooting steps do not resolve the problem, please contact qualified technical support.

7. User Tips

While no specific user tips from reviews or Q&A were available, here are some general recommendations for optimal use:

  • Regular Monitoring: Periodically check the temporary power consumption to track usage over specific periods, and reset it as needed for new measurements.
  • Environmental Awareness: Always ensure the meter is installed in a suitable environment to prevent damage from moisture, dust, or extreme temperatures.
  • Safety First: Always prioritize safety. If you are unsure about any installation or wiring procedures, consult a certified electrician.

8. Warranty and Support

For any technical assistance, warranty claims, or support inquiries regarding your Gaqqee DDS6619 energy meter, please contact the manufacturer or your point of purchase. Ensure you have your product model number (DDS6619) and any relevant purchase information available when seeking support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.