1. Product Overview
The PowMr MPPT Solar Charge Controller is a powerful and high-quality solar charger designed for various battery types, automatically identifying battery voltage. It is suitable for a wide range of applications including solar working stations and home use.
This controller utilizes advanced Maximum Power Point Tracking (MPPT) technology, achieving a charging conversion efficiency of up to 97%. It features a built-in DSP controller for high performance and automatically switches for 12V, 24V, 36V, and 48V battery banks.
Video: Overview of PowMr Keeper series solar charge controllers, highlighting key features like MPPT charging efficiency, maximum charging current, 3-stage charging algorithm, maximum PV input voltage, system voltage compatibility, and DC output capabilities.
Key Features:
- 100% MPPT technology for optimal power harvesting.
- Built-in DSP controller for high performance.
- Automatic voltage recognition for 12V/24V/36V/48V battery banks.
- 3-stage charging algorithm to optimize battery performance and extend battery life.
- Comprehensive protection features: Overcharge protection, Input PV polarity reverse protection, Output limited current protection, Over-temperature protection.
- Troubleshooting promotion function for easy diagnostics.
- Compatible with various battery types: Sealed lead acid, Vented, Gel, LiFePO4, Li(NiCoMn)O2, and Lithium batteries.
- Easy to mount design.
Important Note: The load output terminal is intended for low-power DC loads only (e.g., lamps: 12V system less than 60W, 24V/36V/48V system less than 100W). Connecting to other loads may damage the controller. The output for the battery does not have polarity reverse protection.

Image: PowMr MPPT Solar Charge Controller (20A-40A model shown).
2. Setup and Installation
2.1. Wiring Precautions
CRITICAL WARNING: Please connect the battery first, and then connect the solar panel after setting the system parameters. If you do not operate in this order, the battery will be damaged.

Image: Solar energy system wiring diagram for the 60A controller, showing connections for PV array, battery, DC load, AC load (via inverter), and breakers.
Connection Steps:
- Step 1: Connect Batteries - Ensure correct polarity.
- Step 2: Connect the Load - Connect your DC loads to the designated terminals.
- Step 3: Connect the Solar Panels - Connect the PV array to the controller.
- Step 4: Connect the Inverter to the Battery - If using an inverter for AC loads, connect it directly to the battery, not to the controller's load terminal. (This step can be ignored if no inverter is used).
2.2. Important Notices
- This MPPT series controller uses a common positive design. The positive poles of the PV array, battery, and load can be grounded simultaneously.
- If an inverter or other high-current device is part of your system, connect it directly to the battery, not to the controller's load terminal.
- When using lithium batteries, it is crucial to set the system voltage first, and then select the corresponding battery type before use. Refer to sections 3.7 (Setting Pages) and 3.9 (System Voltage Setting) for detailed instructions.

Image: Example of controller wiring connections for PV, Battery, and Load terminals.
3. Operation
3.1. LCD Screen Overview
The controller features a backlight LCD screen that displays various system parameters and status indicators. Understanding these icons is key to operating your controller effectively.

Image: Detailed view of the 60A controller's LCD screen and functional design, showing various display parameters and fan cooling.
Status Icons:
| Item | Icon | Status |
|---|---|---|
| PV array | Sun / Moon | Day / Night |
| PV array | PV to MPPT to Battery | Charging |
| Battery | Battery icon | Uncharged / Battery capacity |
| Battery | LiPo / LiFe | Battery type |
| Load | Light bulb | Load on / Load off |
3.2. Button Functions
The controller has two main buttons: MENU and SET.
| Button | Function |
|---|---|
| MENU | Short Press: Switch down through interfaces. Long Press (3 seconds): Enter the next interface. |
| SET | Short Press: Switch up through interfaces. Long Press (3 seconds): Exit without saving. |
3.3. Boot Screen
When the system is powered on, the LCD will first display a starting interface, followed by the battery voltage, and then the software revision. This sequence confirms the controller is powering on correctly.
3.4. Navigation and Settings
After the controller powers on, the LCD screen will enter the main page. From the main page:
- Switching Main Loop Pages: Short press 'MENU' or 'SET' to cycle through the main display pages (e.g., battery temperature, charging current, accumulated charging/discharging AH).
- Entering Setting Pages: Long press 'MENU' for 3 seconds to enter the setting page.
- Navigating Setting Pages: Once in the setting page, short press 'MENU' or 'SET' to switch between different setting parameters.
- Saving Settings: After adjusting parameters, long press 'MENU' for 3 seconds to save the settings.
- Exiting Without Saving: Long press 'SET' for 3 seconds to return to the main page without saving changes.
Note: If no action is taken for 15 seconds on the secondary interface, it will automatically switch back to the first interface without saving any changes.
3.5. Load Switch On/Off
On the main page, the 'SET' button can be short-pressed to switch the load output on or off. This function is available in any load operating mode.
3.6. Battery Type Configuration
It is crucial to correctly configure the battery type for optimal charging and battery longevity.
- From the main page, long press 'MENU' for 3 seconds to enter the setting page.
- Short press 'MENU' until you reach the battery type page (User Mode 1).
- Long press 'MENU' for 3 seconds to enter the battery type selection.
- Short press 'MENU' or 'SET' to cycle through available battery types: GEL, Sealed, Flooded, and various Lithium battery types (e.g., 4S LiFePO4, 5S LiFePO4, 3S Lithium-ion, 4S Lithium-ion, User Mode 2 for custom lithium settings).
- For custom lithium battery settings (User Mode 2), long press 'MENU' for 3 seconds on the specific lithium battery page. The parameters on the screen will start flashing. Keep long pressing 'MENU' for 3 seconds to set the battery capacity. Use short presses of 'MENU' or 'SET' to adjust the capacity. Long press 'MENU' for 3 seconds to save.
Reminder: For lithium batteries, always set the system voltage before selecting the battery type.
Battery Type Display Codes:
| Display | Battery type |
|---|---|
| USE 1 | Lead-acid battery custom |
| GEL | Colloidal lead acid battery |
| SLD | Sealed lead acid battery |
| FLD | Valve-Regulated Lead-Acid Battery |
| 4*3.2 | 4S LiFePO4 battery |
| 5*3.2 | 5S LiFePO4 battery |
| 3*3.7 | 3S Lithium-ion battery |
| 4*3.7 | 4S Lithium-ion battery |
| USE 2 | Lithium battery custom |
3.7. System Voltage Setting
After configuring the battery type, proceed to set the system voltage. The 'AUTO' setting allows the controller to automatically detect the system voltage (12V or 24V).
- From the setting pages, navigate to the system voltage page.
- Long press 'MENU' for 3 seconds until 'AUTO' starts to flash.
- Short press 'MENU' or 'SET' to select between 'AUTO', '12V', or '24V'.
- Long press 'MENU' for 3 seconds to save the selection.
3.8. Battery Charging Parameters
If you select a custom battery type (USE1/USE2), you can configure specific charging voltages. When a voltage parameter interface can be configured, a '!' icon will be displayed above the numerical value.
Default Battery Parameters (for reference):
| Parameter | USE 1 | GEL | SLD | FLD |
|---|---|---|---|---|
| Resume charge voltage | 13.6V | 13.6V | 13.6V | 13.6V |
| Constant voltage charge voltage | 14.4V | 14.4V | 14.4V | 14.4V |
| Equalization charge voltage | 14.6V | 14.2V | 14.6V | 14.8V |
| Absorption charge voltage | 14.4V | 14.2V | 14.4V | 14.6V |
| Float charge voltage | 13.8V | 13.8V | 13.8V | 13.8V |
| Low voltage protection voltage | 10.8V | 10.8V | 10.8V | 10.8V |
| Low voltage recovery voltage | 12.6V | 12.6V | 12.6V | 12.6V |
| Parameter | 4*3.2 | 5*3.2 | 3*3.7 | 4*3.7 | USE 2 |
|---|---|---|---|---|---|
| Resume charge voltage | 13.0V | 16.2V | 12.0V | 16.0V | 13.6V |
| Constant voltage charge voltage | 14.4V | 18.0V | 12.6V | 16.8V | 14.4V |
| Equalization charge voltage | - | - | - | - | - |
| Absorption charge voltage | - | - | - | - | - |
| Float charge voltage | - | - | - | - | - |
| Low voltage protection voltage | 11.2V | 14.0V | 9.9V | 13.2V | 11.2V |
| Low voltage recovery voltage | 12.8V | 16.0V | 11.1V | 14.8V | 12.8V |
3.9. Load Working Modes
The controller offers four distinct load working modes, allowing you to configure load output conditions and durations based on specific application requirements.
- LD1 (Regular Mode): The load operates normally and can be manually turned on or off.
- LD2 (Light Control Mode): The load automatically turns on at dusk and turns off at dawn.
- LD3 (Light & Time Control Mode): The load turns on after dark for a specified duration and turns off before dawn. The controller automatically identifies dark and light conditions based on the local environment.
- LD4 (Reverse Light Control Mode): The load automatically turns on at dawn and turns off at dark.
In light control, light & time control, and reverse light control modes, the controller will start or stop the load with a delay of approximately 30 seconds after light conditions are detected or disappear.
3.10. PV Voltage Page
To view the current PV (Photovoltaic) voltage, long press the 'SET' button for 3 seconds to switch between the main page and the PV voltage display page.
3.11. Setting Equalization and Absorption Charging Duration
To adjust the duration for equalization or absorption charging:
- Navigate to the respective equalization or absorption charge page from the main page.
- Long press 'MENU' for 3 seconds until the parameter starts to flash.
- Keep pressing 'MENU' for 3 seconds to enter the duration setting page.
- Short press 'MENU' or 'SET' to increase or decrease the time.
- Long press 'MENU' for 3 seconds to save the new duration.
4. Maintenance
To ensure the longevity and optimal performance of your PowMr MPPT Solar Charge Controller, regular maintenance is recommended:
- Keep Clean: Periodically clean the exterior of the controller to prevent dust and debris buildup, especially around the cooling fan and vents. The controller uses forced air cooling, so clear airflow is essential.
- Check Connections: Regularly inspect all wiring connections (PV, battery, load) to ensure they are tight and free from corrosion. Loose connections can lead to power loss or damage.
- Monitor Performance: Observe the LCD display for any unusual readings or error codes. Address any issues promptly using the troubleshooting guide.
- Battery Health: Ensure your batteries are well-maintained according to their manufacturer's guidelines. The controller optimizes charging, but battery health is crucial for overall system efficiency.

Image: Internal view of the controller, highlighting components like the copper coil transformer and capacitance, which benefit from proper cooling.
5. Troubleshooting
5.1. Protection Functions
The controller is equipped with multiple protection features to safeguard the system. When a protection is triggered, the controller will react as follows:
| Protection | Condition | Status |
|---|---|---|
| Solar panel reversed | Solar panel connected with reversed polarity (if battery is not connected). | Controller is not broken. |
| Battery is reversed | Battery connected with reversed polarity (if PV is unconnected). | Controller is not broken. |
| Battery over-voltage | Battery voltage reaches the over-voltage point. | Stop charging and discharging. |
| Battery over-discharge | Battery voltage drops below the under-voltage point. | Stop discharging. |
| Over-load | The load current exceeds the rated current. | Turn off the output. |
5.2. Fault Management and Error Codes
The controller displays error codes to help diagnose issues. Fault codes consist of an 'E' followed by two digits. The first digit indicates the current error count, and the second digit indicates the specific fault condition. For example, 'E-12' means there is one error at the moment, and the specific reason is overvoltage in the battery.
| Error Code | Cause | Correction |
|---|---|---|
| E1 (Ex1) | Battery over discharge. | The load will stop automatically and recover when battery voltage reaches 12.6V (LVR). |
| E2 (Ex2) | Battery over voltage. | Make sure the set high voltage disconnection voltage is above battery voltage and reconnect PV array. |
| E3 (Ex3) | Over load. | Reduce load or check load connection. |
| E5 (Ex5) | Controller overheating. | The controller will restart after it cools down. |
| E6 (Ex6) | Input voltage of solar panel is too high. | Check voltage of solar panel and reduce quantities of solar panel in series. |
| E7 (Ex7) | No operation. | Controller will restart after setting system voltage. |
| PV array indicator is off when sunlight is enough. | Solar panel is disconnected. | Check whether PV array connection is proper or not. |
| No sign on the LCD when connection is right. | 1. Battery voltage is less than 8V. 2. Voltage of solar panel is less than battery voltage. | 1. Check battery voltage (at least 8V to activate the controller). 2. The voltage of PV must be higher than battery voltage. |
6. Specifications

Image: Comparison highlighting PowMr MPPT Controller's superior efficiency, wider battery compatibility (12V/24V/36V/48V), and higher current/PV voltage limits (Max. PV 160VDC) compared to other controllers.
General Technical Data:
| Parameter | 20A | 30A | 40A | 60A |
|---|---|---|---|---|
| Charging Mode | 3-stage: Constant Current (MPPT), Constant Voltage, Floating | 4-stage: Constant current (MPPT), Constant voltage (Absorption Voltage), floating charge, bulk charge | ||
| System Voltage | 12/24V Auto recognized | 12/24/36/48V Auto | ||
| Max PV Input Power | 260W (12V), 520W (24V) | 390W (12V), 780W (24V) | 520W (12V), 1040W (24V) | 720W (12V), 1440W (24V), 2160W (36V), 2880W (48V) |
| Max PV Input Voltage | 60V | 75V | 100V | 150Voc |
| Battery voltage automatic recognition | 8V-32V | 12V System (8.7V-15.5V); 24V System (16V-31V); 36V System (33V-41V); 48V System (42V-64V) | ||
| Limited Current Protection | 20A | 30A | 40A | 60A |
| Battery type | User default, Sealed, Flooded, GEL, LiFePO4, Li(NiCoMn)O2 | |||
| Enclosure | IP30 | IP21 | ||
| Rated Discharge Current | 20A | 20A | 30A | 30A |
| Static loss | ≤50mA | |||
| HVD (High Voltage Disconnect) | Lead acid battery 16V | |||
| Light control voltage | 5V/10A | |||
| Temperature compensation coefficient | -4mV/°C/2V (25℃) | |||
| Discharge loop voltage drop | ≤0.2V | |||
| LCD temperature | -20°C ~ +70°C | |||
| Operating temperature | -20°C ~ +55°C | |||
| Storage temperature | -30°C ~ +80°C | |||
| Working humidity | ≤90%, No condensation | |||
| Protection class | IP30 (20A-40A), IP21 (60A) | |||
| Grounded type | Positive grounded | |||
| Aperture for installation | Φ5mm | |||
*Note: Above parameters are for 12V system at 25°C; values are twice for 24V system.
Charging Voltage Parameters (for specific battery types):
| Parameter | GEL | SLD | FLD |
|---|---|---|---|
| Equalize charging voltage | 14.2V | 14.6V | 14.6V (Duration: 2 hours) |
| Absorption charging voltage | No | 14.4V | 14.8V (Duration: 2 hours) |
| Float charging voltage | 13.8V | 13.8V | 13.8V |
| LVR (Low Voltage Recovery) | 12.6V | 12.6V | 12.6V |
| LVD (Low Voltage Disconnect) | 10.8V | 10.8V | 10.8V |
*Note: These parameters are for Maintenance-free lead-acid battery types.
7. User Tips
- Prioritize Battery Connection: Always connect the battery to the controller first, and disconnect it last. This prevents potential damage to the controller or battery.
- Lithium Battery Setup: If using lithium batteries, remember to set the system voltage and then the specific battery type in the controller's settings before connecting the solar panels. This is a critical step for proper operation.
- Inverter Connection: For optimal performance and safety, connect your inverter directly to the battery bank, not through the controller's load terminals.
- Understand Load Modes: Familiarize yourself with the four load output modes (LD1, LD2, LD3, LD4) to effectively manage your DC loads based on your specific needs (e.g., automatic light control, timed operation).
- Monitor PV Voltage: Regularly check the PV input voltage on the controller's display to ensure it's within the specified limits for your model (e.g., Max PV 160VDC for 60A model).
8. Warranty and Support
8.1. Warranty Information
The PowMr MPPT Solar Charge Controller comes with a 1-Year Warranty. For specific components, a 2-year guarantee may apply, with fans guaranteed for 5000 hours.
8.2. Contact and Support
For technical support, inquiries, or warranty claims, please contact:
- Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Website: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
A detailed user manual in PDF format is also available for download: View User Manual (PDF)