1. Introduction
The Hantek USB Virtual Oscilloscope is a PC-based 4-channel digital storage oscilloscope designed for comprehensive automotive diagnostics and general electronic measurements. It offers high sampling rates, broad bandwidth, and compatibility with Windows operating systems, making it a versatile tool for professionals and enthusiasts alike.
2. Package Contents
Please verify that all items are present in your package:
- Hantek USB Virtual Oscilloscope Unit (Model: 6074BE, 6074BC, 6074BD, 6254BD, or 6254BE)
- Oscilloscope Probes (quantity may vary by model, e.g., 2 passive probes)
- BNC to Clip Cables (e.g., 2 or 3 gator clip lines)
- USB Cable
- Software CD (contains drivers and user manual)
- Specific automotive accessories (e.g., HT307, HT19, HT18A, HT30A, HT25, depending on model)

3. Product Overview
The Hantek USB Virtual Oscilloscope features a compact and durable design with an anodized aluminum casing for heat and abrasion resistance. It connects to your computer via a USB 2.0 interface, drawing power directly from the USB port, eliminating the need for an external power supply.

Interface Description:
- USBXI Interface: For connecting to the PC.
- USB Interface: Standard USB connection for data and power.
- CH1, CH2, CH3, CH4 Trigger Sources: BNC connectors for connecting probes to the measurement points.
4. Setup Instructions
4.1. Software Installation
- Insert the provided software CD into your computer's CD/DVD drive.
- Follow the on-screen instructions to install the Hantek oscilloscope software and drivers.
- Alternatively, download the latest software and drivers from the official Hantek website for compatibility with Windows 7, Windows 8, and Windows 10.
4.2. Hardware Connection
- Connect the Hantek oscilloscope unit to your computer using the supplied USB cable. The device is plug-and-play and does not require an external power supply.
- Attach the appropriate probes (e.g., passive probes, BNC-clip cables, or specialized automotive probes like HT307, HT19, HT18A, HT30A, HT25) to the CH1-CH4 trigger source inputs on the oscilloscope unit.
- Connect the other end of the probes to the desired measurement points on the circuit or vehicle component.

For a visual guide on connecting the oscilloscope for automotive testing, please refer to the demonstration video below:
5. Operating Instructions
The Hantek software provides a user-friendly interface for various measurement and diagnostic tasks.
5.1. General Oscilloscope Functions
- Waveform Display: View real-time waveforms on your computer screen.
- Automatic Measurement: Access over 20 types of automatic measurement functions including Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, and Duty Cycle.
- Trigger Function: Utilize resourceful trigger modes such as Edge, Pulse, Video, and Alternative to stabilize waveforms.
- Cursor Tracking: Dynamic cursor tracking allows for precise measurement of waveform parameters.
- Waveform Record & Replay: Capture and review waveform data for detailed analysis.
- Waveform Processing: Perform mathematical operations (+,-,x,÷,FFT, Invert), adjust afterglow, and control lightness.
- FFT Spectrum Analyzer: Analyze frequency components of signals.


5.2. Automotive Diagnostic Functions
The Hantek oscilloscope is equipped with over 80 types of automotive measurement functions, categorized as follows:
- First Diagnosis: Intake manifold vacuum & ignition, petrol fumes adjusting valve vacuum & ignition, idle exhaust ignition, starting exhaust ignition.
- Ignition: Primary and secondary ignition analysis.
- Sensors: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position.
- Bus Diagnosis: CAN bus data examination, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus.
- Performer: Petrol/Diesel engine performance analysis.
- Startup & Charge: Analysis of vehicle starting and charging circuits.


For a detailed demonstration of automotive diagnostic features, please watch the video below:
6. Specifications
Below are the general specifications for the Hantek 6000 Series USB Virtual Oscilloscopes. Specific models may have slight variations.

| Feature | Specification |
|---|---|
| Model | Hantek6074BE |
| Bandwidth | 70MHz |
| Channel | 4 CH |
| Real-time Sampling Rate | 1GSa/s |
| Memory Depth | 64K |
| Time Base Precision | ±50ppm |
| Time Base Range | 2ns/div-1000s/div (1-2-4 sequences) |
| Input Impedance | 1MΩ 25pF |
| Input Sensitivity | 2mV/div~10V/div |
| Vertical Resolution | 8Bit |
| Vertical Displacement Range | 2mV ~ 10V/div @ x1 probe; 20mV ~ 100V/div @ x10 probe; 200mV ~ 1000V/div @ x100 probe; 2V ~ 10000V/div @ x1000 probe |
| DC Gain Accuracy | ±3% |
| Bandwidth | 20MHz |
| Trigger Mode | Edge, Pulse, Video, Alternative |
| Trigger Source | CH1, CH2, CH3, CH4 |
| Waveform Signal Process | +,-,x,÷,FFT, Invert |
| Cursors Measurement | Cross, Trace, Horizontal, Vertical |
| Auto Measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle |
| Volume | 175mm * 105mm * 25mm |
| Weight | 0.9KG |
Note: The 6074BC model does not include the car test option function, but other features are identical to the 6074BE. The 6074BD model includes a 1CH signal generator.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Avoid abrasive cleaners or solvents.
- Storage: Store the oscilloscope in a cool, dry place away from direct sunlight and extreme temperatures.
- Software Updates: Regularly check the Hantek website for software and driver updates to ensure optimal performance and access to new features.
- Probe Care: Handle probes carefully. Avoid bending or stressing the cables excessively.
8. Troubleshooting
- Software Not Recognizing Device: Ensure all drivers are correctly installed from the provided CD or the official Hantek website. Try connecting to a different USB port.
- No Waveform Display: Check probe connections to both the oscilloscope and the measurement point. Verify that the input signal is within the device's measurement range.
- Incorrect Readings: Calibrate the oscilloscope if available in the software settings. Ensure probes are correctly configured (e.g., 1x, 10x attenuation settings).
- Software Language Issues: The software supports multiple languages. Navigate to the 'Utility' menu and select 'Language' to choose your preferred language.

9. User Tips
- Portability: The compact size and USB power make this oscilloscope ideal for mobile use and business trips.
- Expandability: A single computer can connect with multiple Hantek oscilloscopes, allowing for easy expansion of channel numbers for complex measurements.
- Software Development: For advanced users, a secondary development library (DLL) and examples for Labview, VB, VC, and QT are provided.
- Attenuators: Some models come with attenuators (e.g., HT307, HT19, HT18A, HT30A, HT25) which are crucial for measuring higher voltages safely and accurately. Ensure you use the correct attenuator for your application.
10. Warranty and Support
Hantek products are factory brand new and genuine. For any product-related inquiries or technical support, please refer to the contact information provided on the official Hantek website or the documentation included with your product. Regular software updates are provided to enhance functionality and performance.