Important Safety Instructions
Before using this product, read and understand all instructions in this manual. Retain this manual for future reference.
Intended Use
This product is for household use only. Use only as described in this manual.
Product Condition
Do not use the product if it is damaged in any way.
User Suitability
This product is intended for persons aged 18 years and above. It may be used by persons with reduced physical, sensory or mental capabilities, or lack of experience/knowledge, only if they are supervised or instructed on safe use and understand the hazards involved.
Product Overview
The RIDEN RK6006-C is a 60V 6A 4-digit adjustable AC to DC step-down voltage bench power supply. It offers precise control over output voltage and current, making it suitable for various electronic applications. This model comes as an assembled set, ready for use without complicated installation or testing.
Included Accessories

- RK Power Supply x1
- X15A Output Cable x1
- Backup Fuse x1
- Micro Communication Cable x1 (inside X15A bag)
- Packing Box
Note: The RK6006-C model does not include an AC power cord; you will need to provide your own. It also does not include an external temperature sensor cable.
Product Video Overview
Specifications

| Parameter | Value |
|---|---|
| Model | RK6006-C |
| Screen | 1.54 inch color HD display |
| Screen brightness setting | 0-5 (6 level in total) |
| Input voltage range | 100-120V/200-240V AC |
| Output voltage range | 0-60.00V |
| Output current range | 0-6.000A |
| Output power range | 0-360W |
| Output voltage setting/reading resolution | 0.01V |
| Output current setting/reading resolution | 0.001A |
| Output voltage accuracy | ±(0.3%+3 digits) |
| Output current accuracy | ±(0.5%+5 digits) |
| Output ripple typical | 100mV VPP |
| Constant voltage mode response time | 2ms (0.1A-5A load) |
| Constant voltage mode load regulation | ±(0.1%+2 digits) |
| Constant current mode load regulation | ±(0.1%+3 digits) |
| Capacity measurement range | 0-9999.99Ah |
| Energy measurement range | 0-9999.99Wh |
| Constant voltage mode response time | ±2% |
| Working temperature range | -10°C ~ 40°C |
| Over temperature protection | System temperature > 90°C |
| Weight (with package) | About 1.3kg |
| Product dimension | 200*115*57mm |
*Ripple measurement method: noise and ripple are measured at X1 range, AC coupling, 20 MHz of bandwidth on your oscilloscope with a 0.1uF parallel capacitor at the output terminals.
Setup
Physical Connections
The RK6006-C comes as an assembled unit. Connect the provided X15A Output Cable to the output terminals on the front panel. Ensure the Micro Communication Cable is connected if you plan to use PC software or mobile app control.

- AC Power Input: Connect your AC power cord (not included) to the AC Power Inlet Socket on the rear panel.
- AC Selector: The RK6006-C is set to use 200-240V AC input by default. If you are using 100-120V AC, please adjust the AC selector switch on the rear panel to the "110V" gear before powering on.
- Output Terminals: Connect the red and black leads of the X15A Output Cable to the corresponding output terminals on the front of the device.
Initial Power-On
After ensuring all connections are secure and the AC selector is correctly set for your region's voltage, flip the Power Switch on the rear panel to the 'ON' position. The device display should illuminate.
Operating Instructions
Front Panel Controls

- V-SET Button: Used to set the output voltage.
- I-SET Button: Used to set the output current.
- OK Button: Confirms selections and enters/exits menus.
- Encoder Potentiometer: Rotates to adjust values, press to confirm or navigate.
- ON/OFF Button: Toggles the output power.
- Micro-USB Port: For PC communication.
Setting Output Voltage and Current
- Press the V-SET button to enter voltage setting mode. The voltage value on the display will blink.
- Rotate the Encoder Potentiometer to adjust the desired voltage. Press the encoder to move between digits.
- Press the OK button to confirm the voltage setting.
- Repeat steps 1-3 for current setting using the I-SET button.
- Once voltage and current are set, press the green ON/OFF button to enable the output. Press again to disable.
Display Styles and Customization

The device supports multiple display styles and color customization for an optimized user experience.
- Classic Style: The system defaults to the classic display style.
- Digits Style: Click the encoder potentiometer to cycle through display styles.
- Nixie Tube Display: Enter the setting interface (usually by long-pressing OK or a dedicated settings button), select "Digits Style", and rotate the encoder to "Seg1" or "Seg2" to enable the Nixie tube display.

The display color supports over 15 colors. To enable color customization, the color customization switch must be turned on in the settings.
Multiple Protection Features

The power supply includes multiple protection mechanisms to safeguard both the device and the connected load:
- OVP (Over Voltage Protection): Protects the load from excessive voltage.
- OCP (Over Current Protection): Protects the load from excessive current.
- OTP (Over Temperature Protection): Shuts down the device if internal temperature exceeds safe limits.
- Power Limit: Limits the output power to prevent overload.
When the output voltage/current exceeds the set protection value, the power supply will automatically stop the output to prevent damage to the device. Abnormal status indications (OVP, OCP, OTP) will be displayed on the screen.
PC Software Control

You can monitor and control the power supply using the dedicated PC software. Connect the device to your computer via the Micro-USB port. The software allows for advanced functions, firmware updates, and detailed monitoring.
- Compatibility: The PC software only supports Windows 7 or above.
- Installation: If you need the software, please install and test it before purchasing the product to ensure compatibility.
Mobile App Control

The RK6006-C supports Bluetooth communication, allowing control via a mobile app (Android and iOS). This provides easy and fast control from your smartphone.
- Android App: For Android (5.0-10.0), download the app from the accessory pack or search for "Ruideng" in the app store.
- Apple iOS App: For iOS (10.0-13.4, iPhone 6-iPhone 11), search for "Ruideng" to download the app.
- Compatibility Note: Due to the variety of mobile phones and operating systems, there may be incompatibilities. It is recommended to install and test the app before purchasing if app control is a critical feature for you.
- Language Setting: The app supports Simplified/Traditional Chinese, English, and more languages will be added.
Maintenance
Firmware Updates

Firmware updates are available to optimize product experience and ensure the device is constantly updated and optimized.
- Update Process: Firmware can be upgraded in normal mode. If the device cannot start normally, you must enter Boot mode to upgrade the firmware. Refer to the official Riden documentation or support for detailed instructions on entering Boot mode and performing updates.
General Care
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Ensure proper ventilation around the heat dissipation fan to prevent overheating.
- Store the device in a dry environment, away from direct sunlight and extreme temperatures.
Troubleshooting
Noise and Fan Operation
- High-frequency noise: A slight high-frequency noise when the switching power supply is unloaded is normal.
- Fan noise: A loud sound when the fan is running is normal. When the ambient temperature is high, the fan may operate even if the unit is unloaded.
- Recommendation: It is recommended to turn off the AC switch when the product is not in use to minimize noise and power consumption.
Abnormal Status Indications
The device provides visual indications for abnormal operating conditions:
- OVP (Over Voltage Status Indication): Appears if the output voltage exceeds the set Over Voltage Protection limit.
- OCP (Over Current Status Indication): Appears if the output current exceeds the set Over Current Protection limit. If the OCP value is lower than the I-SET value, the output will shut down for protection. If the OCP value is higher than the I-SET value, and the output is shorted, it will enter constant current mode, suitable for constant current devices like high power LED lamps.
- OTP (Over Temperature Status Indication): Appears if the internal temperature exceeds the safe operating limit (System temperature > 90°C).
If any of these indications appear, immediately disconnect the load and investigate the cause before resuming operation.
User Tips
- For optimal performance, ensure a stable AC input. Some users have successfully connected the unit to a 30V AC source with diodes and capacitors to achieve stable DC output up to 6A at 40V DC.
- The device is noted for its ability to filter out voltage fluctuations, providing a clean DC output.
- Consider the RK6006-BT model if an external temperature sensor and Bluetooth board are desired, as the RK6006-C does not include these.
Frequently Asked Questions (FAQ)
- Q: What type of product is this?
- A: This is a power supply, specifically an adjustable AC to DC step-down voltage bench power supply.
Manufacturer Information
Product Name: Measuring instruments
Manufacturer: Shenzhen Pingtudi Electronic Technology Co., Ltd.
Address: Building A, Jianye Tai Industrial Zone, No. 11 Minhuan Road, Longhua District, Longhua Street, Shenzhen, Guangdong, CN (China)
EU Representative (EC REP):
SUCCESS COURIER SLCALLE RIO TORMES NUM.1,
PLANTA 1, DERECHA, OFICINA 3
Fuenlabrada Madrid, Spain
TEL: +34-910602659
Email: successservice2@hotmail.com
Compliance Information

This product complies with relevant international standards. The following markings are present on the product:
- CE: Conforms to European Union health, safety, and environmental protection standards.
- FC: Conforms to Federal Communications Commission standards.
- RoHS: Compliant with the Restriction of Hazardous Substances Directive.
- WEEE (Waste Electrical and Electronic Equipment): Indicates that the product should not be disposed of with other household waste.
The product is manufactured in China.
For a detailed user manual in PDF format, please refer to the official documentation: User manual (PDF).
Warranty and Support
For warranty information, technical support, or service inquiries, please contact the manufacturer or your point of purchase. Keep your purchase receipt as proof of purchase for any warranty claims.