Signal Fire ZS-20C-V20

Contents

Signal Fire ZS-20C-V20 Optical Power Meter and Visual Fault Locator

User Instruction Manual

1. Introduction

The Signal Fire ZS-20C-V20 is a compact and versatile fiber optic tool kit designed for FTTH (Fiber To The Home) applications. It integrates multiple essential functions including an Optical Power Meter (OPM), Visual Fault Locator (VFL), LED flashlight, and RJ-45 cable test capabilities. This manual provides detailed instructions for the safe and efficient use of your device.

2. Safety Information

  • Do not look directly into the VFL output port or any fiber connected to it, as the laser light can cause eye damage.
  • Keep the device away from water and high humidity environments.
  • Avoid dropping or subjecting the device to strong impacts.
  • Use only the specified Type-C cable for charging.
  • Ensure connectors are clean before use to prevent inaccurate readings and damage.
  • Do not attempt to disassemble or repair the device yourself. Contact qualified personnel for service.

3. Package Contents

Please check the contents of your package. If any items are missing or damaged, contact your supplier.

  • ZS-20C-V20 Main Unit (OPM/VFL/LED/Cable Tester) x1
  • User Manual x1
  • Type-C Charging Cable x1
  • Lanyard x1
  • Storage Box x1
Image showing the Signal Fire ZS-20C-V20 device, its manual, Type-C cable, lanyard, and storage box.
Figure 3.1: Package Contents

4. Product Overview

The ZS-20C-V20 features a compact design with a 4.7-inch body, making it highly portable. It includes a clear display for readings and intuitive button controls.

Front view of the Signal Fire ZS-20C-V20 device, highlighting its compact size and integrated functions: OPM, VFL, LED, and Cable Test.
Figure 4.1: Device Front View and Key Features

4.1 Key Features

  • Optical Power Meter (OPM): High-precision measurements across multiple wavelengths (850/1300/1310/1490/1550/1625nm) with ±0.2dB accuracy.
  • Visual Fault Locator (VFL): Stable and strong light source (20mW) for easily penetrating long-distance optical fibers.
  • LED Flashlight: Built-in high-brightness LED for working in dark environments.
  • RJ-45 Cable Test: Integrated remote cable module for network cable testing.
  • Data Storage: 500 loop coverage for storing and reviewing measurement records.
  • Wavelength Memory: Remembers the last used wavelength upon power-on.
  • Energy Saving: Automatic shutdown after 10 minutes of inactivity.
  • User Self-Calibration: Allows for DIY adjustment of offset settings.
  • Type-C Interface: Convenient charging.
  • Compact Body: 100mm x 59mm x 28mm, weighing only 95g.
Detailed overview of the Signal Fire ZS-20C-V20, showing its compact body, 500 data storage, Type-C interface, backlight, wavelength memory, and 450mAh lithium battery.
Figure 4.2: Detailed Features Overview

5. Setup

5.1 Charging the Device

The ZS-20C-V20 is equipped with a Type-C interface for charging. Connect the provided Type-C cable to the device's USB port and plug the other end into a compatible USB power adapter (not included).

  • A full charge takes approximately 3 hours.
  • The device offers up to 60 hours of use (OPM only) and 90 days of standby in full power shutdown state.
Image showing the Type-C charging port of the Signal Fire ZS-20C-V20 and various charging scenarios like wall adapter, power bank, and car charger.
Figure 5.1: Type-C Charging Interface

5.2 Connecting Fiber Optic Cables

The OPM and VFL ports use a 2.5mm universal connector, compatible with FC/SC/ST adapters. Ensure the fiber optic connector is clean before insertion.

  1. Remove the protective cap from the OPM or VFL port.
  2. Clean the fiber optic connector end-face using appropriate cleaning tools.
  3. Carefully insert the fiber optic connector into the corresponding port until it clicks into place.
Image demonstrating how to connect a fiber optic cable to the OPM port of the Signal Fire ZS-20C-V20.
Figure 5.2: Fiber Optic Cable Connection

5.3 Cable Test Module

The device features a built-in remote cable module for RJ-45 cable testing.

  1. To detach the remote module, press the lock key located on the side of the device and pull the module out.
  2. To re-attach, align the module with the main unit and push it in until it locks tightly.
Image showing the detachable cable test module of the Signal Fire ZS-20C-V20 and how to connect RJ-45 cables for testing.
Figure 5.3: Cable Test Module

6. Operating Instructions

6.1 Power On/Off and Energy Saving

  • Power On: Short press the ON/OFF button to turn on the device.
  • Auto-Off: The device has an auto-off function and will automatically shut down after 10 minutes of inactivity to conserve battery.
  • Disable Auto-Off: If continuous operation is needed, long press the ON/OFF button until a clock icon appears on the screen when turning on the device.
  • Power Off: Short press the ON/OFF button to turn off the device.
Image illustrating the energy saving function and wavelength switching on the Signal Fire ZS-20C-V20.
Figure 6.1: Power and Energy Saving

6.2 Optical Power Meter (OPM) Operation

  1. Select Wavelength: Short press the Wavelength button to cycle through the available calibrated wavelengths (850/1300/1310/1490/1550/1625nm). The device will remember the last used wavelength.
  2. Switch Unit/Check Reference: Short press the REF button to switch between dBm, dB, and mW units, or to check the reference (REF) value.
  3. Set Reference (REF) Value: Long press the REF button to set the current power reading as the reference value.
  4. Measurement: Connect the fiber optic cable to the OPM port. The device will display the optical power in the selected unit and wavelength.

6.3 Visual Fault Locator (VFL) Operation

  1. Activate VFL: Short press the VFL button to activate the Visual Fault Locator.
  2. Switch Output Mode: Short press the VFL button again to cycle through VFL output modes: ON (continuous light), GLINT (flashing light), and OFF.
  3. Fault Detection: Connect the fiber optic cable to the VFL port. Observe the fiber for red light leakage, which indicates breaks, bends, or poor connections.
Image showing the VFL function of the Signal Fire ZS-20C-V20, demonstrating its stable and strong light source for fault detection.
Figure 6.2: VFL Operation

6.4 LED Flashlight

The device includes an LED flashlight for convenience in dark environments.

  • Turn On/Off: Short press the LED button (flashlight icon) to turn the LED light on or off.
Image showing the LED flashlight function of the Signal Fire ZS-20C-V20, useful for dark environments.
Figure 6.3: LED Flashlight

6.5 RJ-45 Cable Test

To test RJ-45 network cables:

  1. Detach the remote cable module as described in Section 5.3.
  2. Connect one end of the RJ-45 cable to the main unit's RJ-45 port and the other end to the remote module's RJ-45 port.
  3. Long press the ON/OFF button to enter/exit cable test mode. The display will show the wiring status.

6.6 Data Storage and Retrieval

The device can store up to 500 measurement records.

  • Save Data: Long press the Save button to save the current measurement data.
  • View Data: Use the up and down arrow keys to scroll through the stored records.
Image showing the data storage and retrieval function of the Signal Fire ZS-20C-V20, indicating 500 loop coverage.
Figure 6.4: Data Storage and Retrieval

6.7 User Self-Calibration

The device allows for DIY adjustment of the OPM offset.

  1. When the device is off, long press the ON/OFF button and the Wavelength button simultaneously to enter the offset setting interface.
  2. Use the up and down arrow keys to adjust the offset range from -5 to +5 dB.
  3. Short press the ON/OFF button to confirm the setting.
Image detailing the user self-calibration function of the Signal Fire ZS-20C-V20, showing button presses for offset adjustment.
Figure 6.5: User Self-Calibration

7. Specifications

ParameterValue
ModelZS-20C-V20
PD TypeInGaAs
OPM Connector2.5mm Universal connector
Calibrated Wavelengths850/1300/1310/1490/1550/1625nm
Display Range-50~+30dBm
Resolution0.01dB
Accuracy*±0.2dB
Modulation Test270/330/1k/2kHz
VFL Connector2.5mm Universal connector
VFL Power20mW
LEDYes
RJ-45 Cable TestYes
InterfaceType-C
BatteryLithium battery
Storage Temperature-20~60°C, < 90%RH
Operating Temperature-10~50°C, < 90%RH
Weight95g
Size100mm×59mm×28mm

*Accuracy measured at 20±3°C, CW, with FC connector, -10dBm.

Image showing the front, back, and side views of the Signal Fire ZS-20C-V20 with its dimensions and a table of product parameters.
Figure 7.1: Product Dimensions and Parameters

8. Maintenance

  • Cleaning Connectors: Always ensure fiber optic connectors are clean before use. Use lint-free wipes and appropriate fiber optic cleaning solutions.
  • Device Cleaning: Wipe the device exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Battery Care: For optimal battery life, avoid fully discharging the device frequently. If storing for an extended period, charge the battery to about 50%.
  • Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

9. Troubleshooting

  • Device not powering on: Ensure the battery is charged. Connect to a Type-C charger and try again.
  • Inaccurate OPM readings: Clean the fiber optic connectors and the OPM port. Ensure the correct wavelength is selected. Perform user self-calibration if necessary.
  • VFL light is dim or absent: Check if the VFL is set to ON or GLINT mode. Ensure the fiber is properly connected.
  • Cable test failure: Ensure the remote module is securely attached or connected. Check the RJ-45 cable for visible damage.
  • Auto-off too quickly: Disable the auto-off function by long pressing the ON/OFF button until the clock icon disappears during power-on.

10. User Tips

  • Portability: The ZS-20C-V20 is designed to be mini, portable, and light. Utilize the included lanyard for easy carrying during fieldwork.
  • Ergonomics: The device is designed for a comfortable grip, ensuring ease of use during prolonged tasks.
Image showing the Signal Fire ZS-20C-V20 being held in hand, carried in a pocket, placed in a bag, and worn with a lanyard, emphasizing its portability.
Figure 10.1: Portability and Ergonomics

11. Warranty and Support

Signal Fire provides a 5-year warranty for this device. For any technical support, warranty claims, or service inquiries, please contact your authorized dealer or Signal Fire customer service. Professional engineers are available to assist with after-sale service and provide free parts if needed.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.