Product Overview
The VEVOR LPG Gas Water Heater provides instant hot water for various applications. This tankless unit is designed for efficiency and convenience, featuring a durable stainless steel shell and copper components. It is suitable for domestic use, outdoor activities like camping and RV showering, and other scenarios where a portable hot water solution is needed.

Figure 1: VEVOR LPG Gas Water Heater and included accessories.
Video 1: Overview of the VEVOR LPG Gas Water Heater features.
Specifications
| Attribute | Value |
|---|---|
| Brand Name | VEVOR |
| Model | L-LPG |
| Product Name | Gas Water Heater |
| Storage / Tankless | Instant / Tankless |
| Power Source | AC |
| Power (W) | 24KW (for 12L model, other capacities vary) |
| Gas Type | LPG |
| Rated Gas Pressure | 2800Pa |
| Water Producing Rate | 6/8/10/12/16/18 L/min (depending on model) |
| Rubber Gas Hose (outer diameter) | 20 mm (0.79 inch) |
| Min. Water Pressure | 0.02 MPa |
| Max. Water Pressure | 0.8 MPa |
| Smoke Extraction Method | Balanced Type |
| Certificate | CE |
| Origin | Mainland China |

Figure 2: Example dimensions for a 6L model (21.7" H x 11.8" W x 5.9" D).

Figure 3: Dimensions for various capacity models (6L, 8L, 10L, 12L, 16L, 18L).
Setup and Installation
Before installation, ensure you have all necessary components and tools. Installation should be performed by a qualified professional in accordance with local codes and regulations.
Components Included:

Figure 4: Shower head kit, hoses, washers, wall plugs, and screws.
Mounting the Unit:
- Select a suitable location for the water heater. Ensure adequate ventilation and clearance from combustible materials. The unit is designed for outdoor or well-ventilated areas, as indicated by "No installation in the room" on the casing.
- Use the mounting brackets on the back of the unit as a template to mark drilling points on the wall.
- Drill holes and insert the provided wall plugs.
- Secure the unit to the wall using the provided screws.

Figure 5: Rear view of the unit with mounting brackets.
Connecting Gas and Water:
- Gas Connection: Connect the LPG gas supply to the gas inlet on the unit using the provided rubber gas hose (20 mm outer diameter) and regulator. Ensure all connections are tight and leak-free.
- Water Inlet: Connect the cold water supply to the water inlet port.
- Water Outlet: Connect the shower hose and shower head to the hot water outlet port.
- Battery Installation: Open the battery compartment (typically for D-type batteries) and insert the required batteries to power the ignition system.

Figure 6: Close-up of water/gas connections and battery compartment.

Figure 7: Example setup showing gas connection to a propane tank.
Operating Instructions
The VEVOR LPG Gas Water Heater is designed for user-friendly operation with intuitive controls.
Control Panel:

Figure 8: Control panel with LED display, Gas Regulator, Water Regulator, and Winter/Summer mode selector.
- Power On: Ensure gas and water supplies are connected and turned on. The unit will typically ignite automatically when water flow is detected.
- Adjusting Water Temperature:
- Use the Water Regulator knob to control the water flow rate. Higher flow generally results in cooler water, while lower flow allows for hotter water.
- Use the Gas Regulator knob to adjust the gas supply to the burner, directly impacting the heating power and water temperature.
- The LED Display shows the current water temperature.
- Seasonal Mode Selection:
- Turn the Winter/Summer mode selector knob to choose the appropriate setting.
- Summer Mode: Low-level fire power, suitable for warmer ambient temperatures.
- Winter Mode: High-level fire power, suitable for colder ambient temperatures to achieve desired hot water.

Figure 9: Seasonal modes for optimal heating efficiency.
Safety Features:
The water heater is equipped with multiple safety protections:
- Anti-Frozen Protection
- Over-Heat Protection
- Wind Blow In Protection
- 20-minute Timer (automatic shut-off)
- Dry Combustion Protection
- Low Water Flow Protection

Figure 10: Multi-level safety protections for user safety and product longevity.
Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your VEVOR LPG Gas Water Heater.
- Cleaning: Periodically clean the exterior of the unit with a soft, damp cloth. Avoid abrasive cleaners.
- Gas Connections: Regularly check gas connections for any signs of leaks. Use a soapy water solution; bubbles indicate a leak.
- Water Connections: Inspect water inlet and outlet connections for leaks or corrosion.
- Ventilation: Ensure the exhaust flue and ventilation openings are clear of obstructions.
- Battery Replacement: Replace the D-type batteries when the ignition becomes weak or fails to ignite.
- Professional Inspection: It is recommended to have the unit inspected by a qualified technician annually to ensure safe and efficient operation.
Troubleshooting
This section provides solutions to common issues you might encounter with your gas water heater.
- No Hot Water:
- Check if the gas supply is open and the gas tank has sufficient fuel.
- Ensure water supply is turned on and water pressure is adequate (min. 0.02 MPa).
- Verify batteries are correctly installed and have sufficient charge.
- Check if the unit is in the correct seasonal mode (Winter/Summer).
- Low Water Flow:
- Inspect water inlet filter for clogs.
- Ensure water pressure from the source is sufficient.
- Adjust the Water Regulator knob to increase flow.
- Unit Not Igniting:
- Check battery charge and replacement if necessary.
- Ensure gas and water are flowing.
- Listen for the ignition click. If no click, check ignition electrodes.
- Water Not Hot Enough:
- Adjust the Gas Regulator to increase gas flow.
- Switch to Winter mode if ambient temperature is low.
- Reduce water flow using the Water Regulator.
- Error Codes on LED Display:
While specific error codes are not detailed here, refer to the full user manual (if available) for a comprehensive list and troubleshooting steps for any displayed codes.
Warranty and Support
VEVOR is committed to providing quality products and customer satisfaction.
- Free Returns: Enjoy free returns within 15 days of purchase.
- Fast Delivery Guarantee: The product is eligible for fast delivery. In case of delays, a JMD160.38 coupon may be collected. Refunds are provided if the package is lost or items are damaged, or if delivery is not made within 20 days.
- Security & Privacy: VEVOR ensures safe payments and protects your personal details, not sharing them with third parties without consent.
- Customer Service: For any issues or support, please contact VEVOR customer service.