MatSee Plus PC321-W-TY

Contents

MatSeePlus PC321-W-TY 3 Phase WiFi Bidirectional Energy Meter

Quick Start Guide and User Manual

1. Welcome

The PC321-W-TY Power Clamp is designed to help you monitor electricity usage in your facility by connecting current transformers (CT clamps) to your power cables. It provides real-time measurements of Voltage, Current, Power Factor, and Active Power, and supports bidirectional energy measurement for both consumption and production.

Key Features:

  • Tuya compliant for smart home integration.
  • Supports Tap-to-Run and automation with other Tuya devices.
  • Compatible with Single/3-phase electricity systems.
  • Includes three current transformers for single-phase applications.
  • Measures real-time Voltage, Current, PowerFactor, ActivePower.
  • Features Bi-Directional measurement.
  • Supports both Energy consumption and Production measurement.
  • Suitable for both residential and commercial applications.
  • Lightweight and easy to install.

2. Safety Handling

WARNING: Failure to follow these safety notices could result in fire, electric shock, other injuries, or damage to the Power Clamp and other property. Read all the safety notices below before using the Power Clamp.

  • The power clamp must be installed and serviced only by a qualified electrical personnel.
  • Do not touch the terminals of the device during testing.
  • Turn off all the power supply for this equipment before installing.
  • Make sure that the power supply is off before connecting or disconnecting it to an auxiliary device.
  • Always use a properly rated voltage sensing device to confirm power is off.
  • Replace all devices, doors and covers before applying power to the equipment.
  • Avoid high humidity or extreme temperatures.
  • Avoid long exposure to direct sunlight or strong ultraviolet light.
  • Do not drop or expose the unit to intense vibration.
  • Do not disassemble or try to repair the unit on your own.
  • Do not expose the unit or its accessories to flammable liquids, gases or other explosives.

Failure to follow these instructions will result in death or serious injury.

3. Get to Know Your Device

Familiarize yourself with the components of your PC321-W-TY Power Clamp:

MatSeePlus PC321-W-TY Power Clamp with three CT clamps and external antenna
Overview of the PC321-W-TY Power Clamp components: main unit, three CT clamps, and external antenna.
  • Main Unit: The central processing unit for energy measurement.
  • LED Indicator: Provides status feedback.
  • Antenna Connector: For connecting the external antenna.
  • CT1, CT2, CT3: Current Transformer inputs.
  • AC Input Cable: For powering the device.
  • Clamp (Current Transformer): Used to measure current flow.
  • External Antenna: Improves wireless signal reception.
Back view of the PC321-W-TY Power Clamp showing the Reset Button and model information.
Back view of the main unit, highlighting the Reset Button and model details.

Reset Button

Press and hold the reset button for 5 seconds until the LED indicator flashes red 3 times quickly. This restores the power clamp to default factory settings (energy data will not be cleared). The device will then enter pairing mode for 3 minutes.

If you wish to clear the energy data, please delete the device from the app, wipe its data, and then add it again.

LED Indicator Status

LED StatusWhat it means
Green LED blinkingWait for pairing
Green LED solid onDevice has connected to cloud.
Red LED solid onDevice is connected to the router, but failed to connect to the cloud.
Red LED blinkingWi-Fi has been configured, but failed to connect to the router.

4. Technical Specifications

Wireless Connectivity

  • Wi-Fi: 802.11 B/G/N20 (2.4GHz frequency)
  • BLE (Bluetooth Low Energy): Bluetooth 4.2
  • RF Characteristics: Operating frequency: 2.4GHz, External antenna, Output Power: Up to +20dBm

Physical Specifications

  • Operating Voltage: 100~240 Vac 50/60 Hz
  • Calibrated Metering Accuracy: ≤ 100W (Within ±2W), >100W (Within ±2%)
  • Operating Environment: Temperature: -20 °C~ +55 °C, Humidity: ≤ 90% non-condensing
  • Dimensions (L x W x H): 86mm x 86mm x 37mm
  • Power Source: AC
  • Battery Included: No
  • Inbox Adaptor: No
  • Hign-concerned Chemical: None
  • State of Assembly: Ready-to-Go
  • Certification: CE, RoHS
  • App Name: Tuya Smart or Smart Life
  • Phase: 3 Phase
  • Measure Range: 80A for Each Phase
  • Direction: Bidirectional
Diagram showing the dimensions of the mounting bracket: 65mm width, 49mm height, and 49mm between screw holes.
Mounting bracket dimensions.

5. Setup and Installation

Please make sure the main power in your facility is OFF before installing!

Installation Steps:

  1. External Antenna Placement: Place the External Antenna outside the electrical panel to ensure that the device's signal is not blocked by metal. The base of the antenna is magnetic and can be adsorbed on iron materials. After placement, screw the External Antenna assembly cable to the Antenna connector on the main unit.
  2. Connect Current Transformer Cables: Attach both ends of the Current Transformer Cables. Spin the waterproof latch clockwise until both ends are tightened and secured.
  3. CT Clamp Direction: Open the CT clamp to identify the arrow (P1→P2 or K→L) or find it on the sticker outside the clamp. This arrow indicates the direction of the CT. The CT supports bi-directional sensing.
Diagram illustrating the correct and incorrect direction for installing CT clamps, emphasizing that all three CTs must face the same direction as indicated by the arrow.
Ensure all 3 CT clamps are installed in the same direction, following the arrow.

For Energy Consumption Measurement: The arrow on the CT should follow the direction of the current flow. In this configuration, the power will be positive, and energy consumption will be accumulated.

Wiring diagram for a 3-phase electricity system to measure energy consumption, showing the PC321 connected to a circuit breaker and three loads (L1, L2, L3) with CT clamps following current direction.
3 Phase electricity wiring diagram for consumption measurement.

For Energy Production Measurement (e.g., Solar PV System): The arrow on the CT should be opposite to the direction of the current flow. In this case, the power will be negative, and energy generation will be accumulated.

Wiring diagram for a 3-phase system with a PV solar inverter, showing the PC321 connected to the grid, circuit breaker, inverter, and loads, with CT clamps oriented for production measurement.
3 Phase with PV system wiring diagram for production measurement.
Wiring diagram for a single-phase system with a PV solar inverter, showing the PC321 connected to the grid, circuit breaker, inverter, and a load, with CT clamps oriented for production measurement.
Single Phase with PV system wiring diagram for production measurement.
  1. Connect AC Input Cable: Connect the AC Input cable to a socket near the Electrical Box to power on the Power Clamp according to the corresponding wiring diagram. Apply the CT on the electric cable and ensure the direction of CT is correct.

Note:

The circuit measured by each CT must be in the same phase as the power supply of that CT. For example, the circuit measured by the CT of L1 is in the same phase as the power supply of L1. You cannot clamp the CT of L1 on the L2 phase if the power supply of L1 is still connected to the L1 phase.

Mounting the Device

The Power Clamp has a mounting bracket for mounting purposes:

  1. Use the mounting bracket as a template to mark the two holes on the wall for installing screws.
  2. Screw the mounting bracket onto the wall according to the marked location. Install wall plugs if necessary.
  3. Locate the hooks of the mounting bracket and line them up with the mounting holes on the Power Clamp. Fit the hooks into the mounting holes. Installation is now completed.
Diagram showing how to mount the PC321-W-TY Power Clamp using its mounting bracket and screws.
Mounting instructions for the main unit.

6. App Configuration

Download the Smart Life App

Please download the application: Smart Life from your App Store or App Market. You can also scan the QR code below to download and install.

QR code for downloading the Smart Life App.
Scan to download the Smart Life App.

Network Configuration (Method 1: Scan)

  1. Open the Smart Life app.
  2. Click the 'Scan' button in the upper right corner of the App Home page.
Screenshot of the Smart Life app home screen, showing the 'Scan' option to add a device.
Smart Life App: Add Device via Scan.

Network Configuration (Method 2: Manual Add with Bluetooth)

  1. Power on the power clamp.
  2. Make sure the LED indicator is flashing green. If not, reset the device (refer to Reset Button section).
  3. Open the Smart Life app and turn on Bluetooth on your phone.
Screenshot of Smart Life app prompting to enable Bluetooth for device discovery.
Smart Life App: Bluetooth permission prompt.

After enabling Bluetooth, the app will search for nearby devices. If a prompt box appears automatically, click 'Add'. If not, click the '+' icon on the top right of the home page to search for devices.

After clicking 'Add', enter your home Wi-Fi account and password (only 2.4GHz Wi-Fi is supported) and wait for the device to be added. If it fails, refer to the Troubleshooting section.

Wiring Video Reference

Video demonstrating the device pairing process and real-time energy monitoring in the Smart Life app.
QR code linking to a wiring video for the energy meter.
Scan for a wiring video tutorial.

7. Operating Instructions

Once successfully configured, the MatSeePlus Power Clamp will send real-time energy data to your Smart Life app. You can monitor various parameters and view historical statistics.

Real-time Monitoring

The app displays real-time data for each phase (A, B, C) including voltage, current, power, and power factor. It also shows total energy consumed and produced.

App screenshot showing real-time energy consumption data for each phase (A, B, C) including voltage, current, active power, and power factor.
App display of energy consumed per phase.
App screenshot showing real-time energy produced data for each phase (A, B, C) including voltage, current, active power, and power factor.
App display of energy produced per phase.

Electricity Statistics

The Smart Life app allows you to check hourly, daily, monthly, and yearly electricity consumption and production in graphical format for both total energy and each phase separately.

App screenshots displaying hourly, daily, and monthly electricity consumption statistics for Phase A.
Hourly, Daily, and Monthly electricity consumption statistics in the app.
App screenshot showing total energy consumed and total energy produced, along with consumption and production for each phase (A, B, C).
Total and per-phase energy consumed and produced.

The app also displays the temperature of the device.

8. Maintenance

  • Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
  • Ensure the external antenna is securely connected and positioned for optimal signal.
  • Regularly check cable connections for any signs of wear or damage.
  • Avoid exposing the device to direct water or excessive moisture.
  • Perform periodic checks of the LED indicator to ensure proper operation and connectivity.

9. Troubleshooting (FAQ)

Wi-Fi configuration of the device failed:

  • Confirm the entered router password is correct.
  • Ensure your Wi-Fi network is 2.4GHz. The device does not support 5GHz Wi-Fi.
  • For iOS users: If you have upgraded to iOS 14 or later, you need to enable the "Local Network" permission for the Smart Life App.
Screenshot of iOS settings showing how to enable Local Network for Smart Life App.
iOS Settings: Enable Local Network for Smart Life App.
  • Confirm that both the location permission of your phone system and the Smart Life App are enabled.

Device not showing data or incorrect readings:

  • Check that the CT clamps are correctly installed and oriented according to the wiring diagrams (following or opposing current flow for consumption/production).
  • Ensure the main power is on and the device is receiving power.
  • Verify that the measured device has a neutral wire, as it is required for voltage, current, and power measurements.
  • Confirm that the circuit measured by each CT is in the same phase as the power supply of that CT.

10. User Tips

  • For optimal Wi-Fi signal, ensure the external antenna is placed in an open area, away from metal obstructions.
  • Regularly review your energy statistics in the app to identify patterns and potential areas for energy saving.
  • Utilize the app's automation features to integrate the energy meter with other smart home devices for enhanced energy management.

11. Warranty and Support

For warranty information and technical support, please refer to the official MatSeePlus website or contact your retailer. Keep your purchase receipt as proof of purchase.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.