1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the FGHGF CDZ11RR Dock Charger Circuit Board. This component is designed as a replacement power board for the charging piles of specific Roborock vacuum cleaner models, including the S7 Maxv Ultra, Q7 Max, and Q7. Please read this manual thoroughly before attempting any installation or replacement to ensure safe and correct usage.
2. Safety Information
WARNING: Risk of Electric Shock!
- Always disconnect the charging dock from the power supply before attempting any installation, removal, or maintenance of the circuit board.
- Only qualified personnel should perform the replacement of internal electronic components.
- Do not expose the circuit board to moisture or liquids.
- Handle the circuit board by its edges to avoid damaging sensitive components or introducing static discharge.
- Ensure all connections are secure and correctly oriented before reconnecting power.
3. Package Contents
Verify that all items are present and undamaged upon opening the package:
- 1x FGHGF CDZ11RR Dock Charger Circuit Board
4. Specifications
| Attribute | Value |
|---|---|
| Model Number | CDZ11RR |
| Brand Name | FGHGF |
| Type | Vacuum Cleaner Parts (Dock Charger Circuit Board) |
| Material | Metal, ABS Plastic |
| Compatibility | Roborock S7 Maxv Ultra, Roborock Q7 Max, Roborock Q7 Charging Piles |
| Origin | Mainland China |
5. Installation and Replacement
This circuit board is intended as a direct replacement for the original power board within compatible Roborock charging docks. Follow these steps carefully:
- Prepare the Work Area: Ensure you have a clean, well-lit, and static-free workspace. Gather necessary tools, which may include small screwdrivers and possibly a spudger for opening plastic casings.
- Disconnect Power: Crucially, unplug the Roborock charging dock from the wall outlet. Do not proceed until power is completely disconnected.
- Access the Old Circuit Board: Carefully open the casing of your Roborock charging dock. This usually involves removing screws and gently prying open plastic clips. Take note of how the original board is positioned and connected.
- Document Connections: Before disconnecting anything, take clear photos of all wire connections to the old circuit board. Pay close attention to the color and position of each wire.
- Remove Old Board: Disconnect all wires and mounting screws securing the old circuit board. Carefully lift it out of the dock.
- Install New Board: Place the new FGHGF CDZ11RR circuit board into the dock, ensuring it aligns with the mounting points. Secure it with the original screws.
- Connect Wires: Refer to your documented photos and the images below to connect the wires to the new circuit board. Ensure the red wire connects to the positive (+) terminal and the black wire to the negative (-) terminal, as shown in the diagrams. The two main power wires are typically connected via spade connectors.


- Reassemble Dock: Once all connections are verified, carefully close the charging dock casing, ensuring no wires are pinched. Secure with screws.
- Test Functionality: Plug the charging dock back into the power outlet. Observe if the dock powers on correctly and if the vacuum cleaner can successfully dock and charge.
6. Operation
The FGHGF CDZ11RR Dock Charger Circuit Board functions as the core power management component within your Roborock charging dock. Once correctly installed, it enables the dock to receive power from the wall outlet and deliver the appropriate charging current to your compatible Roborock vacuum cleaner. There are no user-adjustable settings on the circuit board itself; its operation is automatic upon proper installation and connection to a power source.
7. Care and Maintenance
- Keep Dry: Ensure the charging dock and its internal components, including the circuit board, remain dry. Moisture can cause damage and electrical hazards.
- Clean Gently: If cleaning is necessary, disconnect power and use a dry, soft brush or compressed air to remove dust from the circuit board. Do not use liquids or abrasive cleaners.
- Avoid Physical Shock: Protect the charging dock from drops or impacts, as this can damage the internal circuit board and other components.
8. Troubleshooting
- Q: The charging dock is not powering on after replacing the circuit board.
- A: Double-check all wire connections to ensure they are secure and correctly oriented (red to positive, black to negative). Verify that the power outlet is functional and the power cable is fully inserted into the dock and the wall.
- Q: My Roborock S7 (non-Maxv) is not charging with this board.
- A: This circuit board is specifically designed for Roborock S7 Maxv Ultra, Q7 Max, and Q7 models. Compatibility with the standard Roborock S7 is not guaranteed and may lead to improper function or damage. Always ensure the replacement part matches your specific vacuum cleaner model.
9. User Tips
- Before purchasing, always confirm the model number of your Roborock charging dock to ensure full compatibility with the CDZ11RR circuit board.
- When replacing electronic components, it's good practice to wear anti-static gloves or use an anti-static wrist strap to prevent damage from electrostatic discharge.
10. Warranty and Support
For any questions regarding the FGHGF CDZ11RR Dock Charger Circuit Board, including installation assistance or troubleshooting beyond the scope of this manual, please contact the seller or manufacturer directly. Keep your purchase records for any potential warranty claims.