1. Introduction
The SUSWE SU600 series Variable Frequency Drive (VFD) is an economical inverter designed for controlling the speed of motors. It converts 220V input to 380V output, or operates directly with 380V input, offering various power ratings from 0.75KW to 7.5KW. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your VFD.
Figure 1: SUSWE SU600 VFD with power and voltage specifications.
2. Safety Information
Please read and understand all safety instructions before installing, operating, or performing maintenance on the VFD. Failure to follow these instructions may result in serious injury or equipment damage.
- Only qualified personnel should install, operate, and maintain this equipment.
- Ensure the power supply is disconnected before any wiring or maintenance work.
- Verify correct voltage and current ratings before connecting the VFD.
- Proper grounding is essential to prevent electric shock.
- Do not touch electrical components immediately after power-off, as residual voltage may be present. Wait at least 5 minutes for capacitors to discharge.
- Install the VFD in a well-ventilated area, free from excessive dust, moisture, and corrosive gases.
3. Installation and Wiring
3.1 Mounting
Mount the VFD vertically on a stable surface, ensuring adequate clearance for ventilation. Refer to the dimensions provided in the specifications section for proper spacing.
3.2 Wiring Diagram
Follow the detailed terminal wiring diagram carefully for all electrical connections. Ensure all connections are secure and correctly polarized.
Figure 2: Detailed Terminal Wiring Diagram.
- Power Input (R, S/L1, T/L2): Connect the main power supply here.
- Motor Output (U, V, W): Connect to the three-phase induction motor.
- Ground Wire: Connect to a reliable ground point.
- Brake Resistor (P+, PB): Optional connection for CNC machine tools or applications requiring rapid deceleration.
- Multifunctional Input Terminals (X1, X2, X3, X4, COM): For external control signals.
- External Keyboard Interface (J11): For connecting an external operation panel.
- Analog Output (AO): DC 0-10V / 0-20mA.
- Analog Input (AI): DC 0-10V / DC 0-20mA, often used with an SK-10K potentiometer.
- RS485 Communication (485+, 485-): For serial communication.
- Relay Output (TA, TC): For external control.
3.3 External Operation Panel
An external operation panel can be connected for remote control and monitoring. This panel provides the same interface as the built-in one.
Figure 3: External Operation Panel Connection.
4. Operation
4.1 Control Panel Overview
The VFD features a user-friendly control panel for programming and operation. Familiarize yourself with the buttons and indicators:
Figure 4: Control Panel Interface.
- PRG (Programming Key): Enters/exits programming mode.
- ENT (Confirm Key): Confirms selections or parameter changes.
- Up/Down Arrows (Incremental/Decrement Keys): Adjusts values or navigates menus.
- RUN Key: Starts motor operation.
- STOP/RST Key: Stops motor operation or resets faults.
- Display: Shows frequency, current, voltage, and fault indicators (FWD, REV, Hz, A, V, ALM).
4.2 Basic Operation
To start the motor, press the RUN key. To stop, press the STOP/RST key. For detailed parameter settings and advanced functions, refer to the full product manual (if available) or contact customer support.
4.3 Product Demonstration Video
Watch this video for a visual guide on the VFD's features and basic operation.
Video 1: SUSWE SU600 VFD Features and Operation.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your VFD. Always disconnect power before performing any maintenance.
- Cleaning: Keep the VFD clean and free from dust. Use a soft, dry cloth. Do not use liquid cleaners.
- Ventilation: Ensure cooling fans are clear of obstructions and functioning properly.
- Connections: Periodically check all electrical connections for tightness.
- Environmental Protection: The main board material is designed to be waterproof, moisture-proof, and mildew-proof, contributing to its durability in various environments.
Figure 5: VFD Internal Components highlighting main board characteristics.
6. Troubleshooting
This section addresses common issues you might encounter. For complex problems, contact technical support.
Common Issues:
- No Power/Display: Check input power connections and circuit breaker. Ensure the VFD is correctly wired.
- Motor Not Running: Verify RUN command, check motor wiring (U, V, W), and ensure no fault indicators (ALM) are active. Check motor parameters in VFD settings.
- Overload Fault: Reduce motor load or check motor current settings. Ensure the motor is not jammed.
- Overvoltage/Undervoltage Fault: Check input power supply stability.
- Is the SU600 suitable for a 3-phase heat pump? The SU600 series offers models with three-phase output (e.g., 220V into three-phase 380V, or three-phase 380V into three-phase 380V). Ensure you select the correct model and power rating that matches your heat pump's specifications. Consult the specifications table for appropriate models.
7. Specifications
7.1 Model Naming Rules (SU-600 Series)
The model numbers follow a specific convention:
- SU-600: Series designation.
- 1R5: Power grade (e.g., 1.5KW).
- G1: Voltage grade (1: Single-phase 220V into three-phase 380V; 2: Single-phase 220V into three-phase 220V; 3: Three-phase 380V into three-phase 380V).
Figure 6: Model Naming Rules and Frequency Converter Series Index.
7.2 Frequency Converter Series Index
| Frequency Converter Mode | Power Supply Capacity (kVA) | Rated Input Current (A) | Rated Output Current (A) | Adapted Motor (kW) | Adapted Motor (HP) |
|---|---|---|---|---|---|
| Single Phase 220V into three phase 380V 50/60HZ | |||||
| SU600-0R75G1 | 1.5 | 3.4 | 2.5 | 0.75 | 1 |
| SU600-1R5G1 | 3 | 5.8 | 3.7 | 1.5 | 2 |
| SU600-2R2G1 | 4 | 7.0 | 5 | 2.2 | 3 |
| SU600-3R7G1 | 5.9 | 10.5 | 8 | 3.7 | 5 |
| SU600-5R5G1 | 8.9 | 14.6 | 13 | 5.5 | 7.5 |
| SU600-7R5G1 | 11 | 21 | 17 | 7.5 | 10 |
| SU600-011G1 | 17 | 26 | 25 | 11 | 15 |
| SU600-015G1 | 21 | 33 | 32 | 15 | 20 |
| Single Phase 220V into three phase 220V 50/60HZ | |||||
| SU600-0R75G2 | 1.5 | 8.2 | 4 | 0.75 | 1 |
| SU600-1R5G2 | 3 | 14 | 7 | 1.5 | 2 |
| SU600-2R2G2 | 4 | 23 | 9.6 | 2.2 | 3 |
| SU600-3R7G2 | 5.5 | 31 | 17 | 3.7 | 4 |
| SU600-5R5G2 | 8.9 | 26 | 25 | 5.5 | 5 |
| SU600-7R5G2 | 21 | 35 | 32 | 7.5 | 10 |
| SU600-011G2 | 25 | 50 | 37.5 | 11 | 15 |
| SU600-015G2 | 32 | 68 | 40 | 15 | 20 |
| Three-phase 380V into three-phase 380V 50/60HZ | |||||
| SU600-0R75G3 | 1.5 | 3.6 | 2.5 | 0.75 | 1 |
| SU600-1R5G3 | 3 | 5.1 | 4.1 | 1.5 | 2 |
| SU600-2R2G3 | 4 | 6 | 5.8 | 2.2 | 3 |
| SU600-3R7G3 | 6.1 | 10.5 | 9 | 3.7 | 5 |
| SU600-5R5G3 | 8.9 | 14 | 13 | 5.5 | 7.5 |
| SU600-7R5G3 | 11 | 21 | 17 | 7.5 | 10 |
| SU600-011G3 | 17 | 26 | 25 | 11 | 15 |
| SU600-015G3 | 21 | 35 | 32 | 15 | 20 |
7.3 General Specifications
- Output Frequency: 50/60Hz
- Output Current: 2.5-13A (varies by model)
- Output Power: >1000KW (This seems to be a general category, specific models have lower power as per table)
- Type: DC/AC Inverters
- Output Type: Triple (Three-phase)
- Certification: CE
- Origin: Mainland China
- Customization: Yes
7.4 Dimensions and Weight (Example: 1.5KW 380V Model SU600-1R5G3)
Figure 7: Example Specifications for SU600-1R5G3.
- Model: SU600-1R5G3
- Adapted Motor: 1.5KW (2HP)
- Input: Three-phase 380V
- Output: Three-phase 380V
- Current: 4.1A
- Dimensions: 147 x 72 x 118.4 mm
- Weight: 0.72 Kg
Figure 8: Dimensions for 3.7kW/5.5kW models.
8. User Tips
- The SU600 series offers high output power and flexibility in customization, making it suitable for various industrial applications.
- Always verify the specific model's power and voltage ratings to ensure compatibility with your motor and power supply.
- For optimal performance and safety, ensure all wiring adheres to local electrical codes and the provided diagrams.
9. Warranty and Support
For any questions, technical assistance, or warranty claims, please contact the seller or manufacturer directly. Provide your product model and purchase details for efficient support.