1. Introduction
Thank you for choosing the SUSWE SU800/SU900 series frequency converter. This manual provides essential information for the correct and safe use of your product. Please read it carefully before installation, operation, or maintenance, and keep it for future reference.
1.1 Safety Information and Notices
Safety notices in this manual are categorized as follows:
- Danger: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury or death.
- Attention: Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury, or equipment damage.
Always operate the device according to the safety notices provided. Any injury or loss resulting from non-compliance with these instructions is not the responsibility of the manufacturer.
For a complete list of parameters and detailed communication protocols, please refer to the full user manual PDF: View User Manual (PDF)
2. Specifications
2.1 Product Information
Figure 2.1: General Product Information
| Attribute | Description |
|---|---|
| Name | General purpose inverter |
| Power specifications | 0.75-45KW |
| Input Voltage | 220V/380V |
| Rated current | 1.5-320A |
| Input frequency | 50/60HZ |
| Protection level | IP20 |
| Temperature range | -20~+60°C |
| Cooling mode | Self-cooling fan |
| Use the motor | Suitable for fans and pumps |
| Product protection | 6 great protections |
| Scope of use | Woodworking machinery, food machinery, textile machinery, plastic machinery, CNC machine printing machinery, automation and other occasions requiring higher motor control |
2.2 Frequency Converter Series Index
Figure 2.2: Frequency Converter Series Index (Single Phase 220V)
Figure 2.3: Frequency Converter Series Index (Three Phase 380V)
The tables above detail the power supply capacity, rated input/output current, and adapted motor power (kW/HP) for both single-phase 220V and three-phase 380V models in the SU800/900 series.
2.3 Certifications
Figure 2.4: Product Certifications
The SUSWE SU800/SU900 series frequency converters are certified with CE, FCC, and RoHS, ensuring compliance with international quality and safety standards.
3. Setup and Installation
3.1 Product Dimensions and Mounting
Figure 3.1: C1 External Unit Dimensions (SU800-0R75G2 to SU800-2R2G2, SU800-0R75G3 to SU900-2R2G3)
Figure 3.2: C2 External Unit Dimensions (SU800-5R5G2 to SU800-7R5G2, SU800-4R0G3 to SU900-7R5G3)
Figure 3.3: C3 External Unit Dimensions (SU900-7R5G3, SU900-11R0G3, SU900-15R0G3)
Figure 3.4: C4 External Unit Dimensions (SU900-18R5G3, SU900-22R0G3)
Figure 3.5: C5 External Unit Dimensions (SU900-18R5G3, SU900-22R0G3)
3.2 Main Circuit Terminals and Wiring
| Terminal Marks | Name | Instruction |
|---|---|---|
| R, S, T/L, N | Power supply input terminals | Connection point of three-phase 380V / single-phase 220VAC power supply |
| P+, PB | Brake electric resistance connect terminals | Connect brake electric resistance |
| U, V, W | Frequency converter output terminals | Connect three phase motor |
| Grounding terminals | Grounding terminals |
3.3 Wiring Diagrams
Below are various wiring diagrams for different power configurations and models. Ensure you select the correct diagram for your specific unit.
Figure 3.6: SU900 7.5KW-22KW G1 Type Wiring Diagram
Figure 3.7: G3 Type Wiring Diagram
Figure 3.8: SU800 4KW-7.5KW G1 Type Wiring Diagram
Figure 3.9: G2 Type Wiring Diagram
Figure 3.10: SU800 0.75KW-2.2KW G1 Type Wiring Diagram
3.4 Control Circuit Terminals
The control circuit wiring for all 800/900 series inverters is similar. Pay close attention to the signal input terminal wiring, as weak analog voltage signals are susceptible to disturbance. Use shielded cables and keep cable distances short (not exceeding 20m). Analog signal sources may require additional filter wave capacitors or iron-oxygen magnetism in disturbed environments.
Figure 3.11: External Extension Cable for Frequency Converter (Dimension: 90mm*68mm)
Figure 3.12: Detachable Smart Panel with Network Cable Connector
The detachable smart panel allows for flexible and convenient adjustment of working conditions using an external extension network cable.
4. Operating Instructions
4.1 Operation and Display Interface
The operating panel allows you to modify function parameters, monitor the working status, and control the frequency converter (start/stop).
Figure 4.1: SU-900 Man-Machine Interactive Key Panel Layout
The panel includes a display area, speed control knob, displacement key, programming key, increment/decrement keys, run key, stop/reset key, confirm key, and multi-function keys.
4.2 Function Parameters
The frequency converter has various parameter groups (P0-P9, PA, PB, PC, PD, PP, A5, b0, U0) that control its operation. These parameters can be set to optimize performance for different applications.
- P0 Group: Basic running parameters (e.g., G/P model, order source select, preset frequency).
- P1 Group: Motor parameters (e.g., motor rated power, voltage, current, frequency, speed).
- P2 Group: Vector parameters (e.g., speed ring ratio gain, filter wave time constant).
- P3 Group: V/F control parameters (e.g., V/F curve setting, torque promote).
- P4 Group: Input terminal parameters (e.g., HDI terminal function, filter wave time).
- P5 Group: Output terminal parameters (e.g., HDO output mode, electric relay function).
- P6 Group: Start and stop control (e.g., startup mode, start frequency, DC brake).
- P7 Group: Keyboard and display (e.g., MF.K key function, LED running display parameters).
- P8 Group: Assist function (e.g., crawl running frequency, jump frequency).
- P9 Group: Failure and protection (e.g., motor overload protection, over voltage loss speed gain).
- PA Group: PID function (e.g., PID setting source, ratio gain).
- PB Group: Swing frequency, IX length and counting.
- PC Group: Multi section order and simple and easy PLC.
- PD Group: Communication parameters (e.g., baud rate, data format, machine address).
- PP Group: Function code management (e.g., user password, parameter initialize).
- A5 Group: Control optimize parameters (e.g., DPWM shift up limit frequency, PWM modulate method).
- b0 Group: Intelligent constant pressure water supply parameter.
- U0 Group: Monitor parameters (e.g., running frequency, setting frequency, output voltage/current).
For detailed parameter settings and their functions, please consult the comprehensive user manual PDF.
4.3 Industry Application Macros
The SU800/SU900 series supports various application macros to simplify configuration for specific uses.
4.3.1 Constant Pressure Water Supply Macro
This macro allows for efficient constant pressure water supply control with strong pressure regulation and sensitive response. It supports single-pump variable frequency and multi-pump power frequency modes. Key parameters include sensor range, target pressure, dormancy, and awakening pressures.
4.3.2 Engraving Machine Macro (400HZ:24000 Transfer)
This macro is designed for engraving machines, allowing for multi-segment speed control via X1, X2, X3, and X4 terminals. The combination of these terminals determines the output frequency (e.g., 0Hz, 100Hz, 150Hz, 200Hz, 250Hz, 300Hz, 350Hz, 400Hz).
5. Maintenance
5.1 General Maintenance
- Regularly inspect the unit for any signs of damage or loose connections.
- Ensure proper ventilation and keep the cooling fan free from dust and obstructions.
- Clean the exterior of the unit with a soft, dry cloth. Do not use liquid cleaners.
5.2 Enhanced Durability Features
Figure 5.1: Three Anti-Paint Process for Circuit Boards
The inverter features a fully automatic double-sided coating equipment with polyurethane cool treatment to improve stability in harsh environments.
Figure 5.2: Welding Process for Industrial Circuit Boards
The welding process adheres to industrial circuit board SMT standards, ensuring smooth and reliable solder paste application for enhanced reliability and gloss of welding.
Figure 5.3: DC Fan for Efficient Heat Dissipation
Equipped with a quick cooling radiator and intelligent start/stop function, the aluminum alloy radiator ensures faster cooling and efficient heat dissipation.
6. Troubleshooting
The SU800/SU900 frequency converter has 24 warning and protection functions. When a failure occurs, the frequency converter will stop output, and the display panel will show an error code. Refer to the tables below for common issues and their solutions.
6.1 Failure Alarm and Policies
| Failure Name | Code | Reason | Treatment |
|---|---|---|---|
| Inverter unit protection | Err1 | Output circuit short circuit, long motor/converter wiring, overheat module, loose internal wiring, abnormal control/drive board. | Solve outer failure, install reactor/filter, check air channel/fan, plug in wiring, seek technical support. |
| Accelerate over current | Err2 | Output circuit grounding/short circuit, incorrect control method, short accelerate time, unsuitable V/F curve, low voltage, starting rotating motor, sudden load, small converter model. | Solve outer failure, process motor parameters, increase accelerate time, adjust V/F curve/voltage, select speed tracing, cancel sudden load, select bigger power grade. |
| Moderate over current | Err3 | Similar to Err2 but related to moderate time. | Similar to Err2 but related to moderate time. |
| Constant speed over current | Err4 | Similar to Err2 but related to constant speed. | Similar to Err2 but related to constant speed. |
| Accelerate over voltage | Err5 | High input voltage, outer force drive motor, short accelerate time, no brake unit/resistance. | Adjust voltage, cancel additional power/add braking resistance, increase accelerate time, install brake unit/resistance. |
| Module overheat | Err14 | Too high environment temperature, air channel blocked, fan damaged, thermal resistor damaged, inverter module damaged. | Reduce environment temperature, clean air channel, renew fan/thermal resistor/inverter module. |
For a complete list of failure alarms and detailed treatment policies, please refer to the full user manual PDF.
6.2 Common Failures and Solutions
| S/N | Failure Appearance | Possible Reason | Solve Method |
|---|---|---|---|
| 1 | Power on but no indication (8.8.8.8.8) | No power grid voltage or too low; switch power supply failure; rectification bridge damaged; control board/keyboard issues. | Check input power supply; seek factory service; check bus line voltage. |
| 2 | Power on repeat indication | Bad contact wiring between drive/control board; damaged apparatus; low power grid voltage. | Re-insert main board pin socket; seek factory service; check power grid voltage. |
| 3 | Power on indicate "Err23" alarm | Motor or output wire grounding short circuit; frequency converter damaged. | Use meter to measure insulation of motor/output wire; seek factory service. |
| 4 | Power on indication normal, indicate "[]" after running | Fan damaged or blocked; outer control terminal wiring short circuit. | Renew fan; solve outer short circuit failure; seek factory service. |
| 6 | Motor not running after frequency converter running | Not connected motor wire well; error frequency converter parameter setting; bad contact between drive board and control board wire; drive board failure. | Confirm wire between frequency converter and motor; renew motor or solve mechanical failure; check and reset motor parameters. |
For a comprehensive list of common failures and their solutions, please refer to the full user manual PDF.
7. User Tips
- Continuous Power Supply: This product provides a continuous power supply with an output range of 0.75-2.0 kW, flexible output current options from 2.5-9.6A, and a variable frequency range of 50-400Hz.
- Compact Design: The unit features a compact size, making it suitable for various installations.
- Customization: The product offers customization options, allowing it to be tailored to specific application needs.
- Programming Manual: For detailed programming instructions and parameter configurations, always refer to the comprehensive user manual PDF.
8. Warranty and Support
8.1 Warranty Description
The frequency converter comes with an 18-month warranty from the date of manufacture (based on the bar code on the product). This warranty covers the frequency converter itself under normal use conditions.
Maintenance fees may be charged if:
- Damage is caused by the user's failure to comply with the manual's provisions.
- Damage results from fire, flood, abnormal voltage, etc.
- Damage is caused by applying the frequency converter to abnormal functions.
Relevant service costs will be calculated according to manufacturer standards. If a contract exists, it will be handled according to the principle of contract priority.
8.2 Technical Support