SUNTEC AN67A 7345-4

Contents

SUNTEC AN67A 7345-4 Oil Pump Instruction Manual

For Boiler Burner Applications

1. Product Overview

The SUNTEC AN67A 7345-4 is a high-quality oil pump specifically designed for use in boiler burner systems. Manufactured in France, this pump ensures reliable fuel delivery and efficient operation of your heating appliance. It features a robust design with clearly marked ports for easy installation and maintenance.

Video: Product showcase of the SUNTEC oil pump, demonstrating its physical appearance and features.

Key Features:

  • Designed for boiler burner applications.
  • Made in France, ensuring quality and precision.
  • Features clearly labeled ports for pressure (P), vacuum (V), and bypass.
  • Adjustable bypass pressure (up to 2 bar max).

2. Specifications

The following specifications are provided for the SUNTEC AN67A 7345-4 oil pump. Refer to the diagrams for visual representation of dimensions and port locations.

Technical diagram of SUNTEC pumps with dimensions, port labels, and capacity chart.

Figure 2.1: Technical diagram showing pump dimensions, port identification, and a capacity curve.

Port Identification (Refer to Figure 2.1):

  1. Suction
  2. Return and internal bypass plug
  3. Nozzle outlet
  4. Pressure gauge port
  5. Vacuum gauge port
  6. Pressure adjustment
  7. Pressure port (only for "7000" series)
Table of SUNTEC oil pump models and their specifications.

Figure 2.2: Table detailing specifications for various SUNTEC oil pump models, including AN series.

Model Specifics (AN67A 7345-4):

CharacteristicValue
ModelAN67A 7345-4
InterfaceG1/4"
Set Pressure9 bars
Max Flow50 L/h
Fuel TypeDiesel
Viscosity2-12 mm²/s (cSt)
Fuel Temperature0-60 °C
Inlet Pressure< 2 bars
Bypass Pressure Max2 bar
OriginMainland China (Manufactured in France)

Flow Label and Axis Rotation:

The pump's flow direction and axis rotation are critical for correct installation. Refer to Figure 2.2 for the flow chart and axis rotation directions:

  • Axis rotation direction (viewed from the axle):
    • A: Clockwise rotation, Right oil outlet
    • B: Clockwise rotation, Left oil outlet
    • C: Counterclockwise rotation, Left oil outlet
    • D: Counterclockwise rotation, Right oil outlet

3. Setup and Installation

Proper installation is crucial for the safe and efficient operation of the oil pump. It is recommended that installation be performed by a qualified technician.

Pre-Installation Checks:

  • Ensure the pump model (AN67A 7345-4) is compatible with your boiler burner system.
  • Verify that the fuel type (Diesel) and operating conditions (temperature, pressure) match the pump's specifications.
  • Inspect the pump for any visible damage from shipping.
  • Confirm the correct axis rotation direction for your burner's motor (refer to Figure 2.2).

Installation Steps:

  1. Mounting: Securely mount the pump to the burner assembly, ensuring it is stable and free from vibrations.
  2. Fuel Line Connections: Connect the suction line to the 'Suction' port (1) and the return line to the 'Return' port (2). Ensure all connections are tight to prevent leaks and air ingress.
  3. Nozzle Outlet: Connect the nozzle line to the 'Nozzle outlet' port (3).
  4. Gauge Connections (Optional): If monitoring pressure and vacuum, connect gauges to the 'Pressure gauge port' (4) and 'Vacuum gauge port' (5) respectively.
  5. Bypass Adjustment: The pump features an adjustable bypass. Ensure it is set correctly for your system, not exceeding 2 bar.
  6. Priming: Before initial operation, ensure the pump is properly primed according to your burner manufacturer's instructions to remove any air from the fuel lines.

4. Operating Instructions

Once installed and primed, the SUNTEC AN67A 7345-4 oil pump operates automatically as part of the boiler burner system.

Normal Operation:

  • The pump will draw fuel from the tank and deliver it under pressure to the burner nozzle when the burner control system calls for heat.
  • The internal bypass mechanism ensures consistent pressure at the nozzle, returning excess fuel to the tank.

Pressure Adjustment:

  • The pressure adjustment screw (6 in Figure 2.1) allows fine-tuning of the pump's output pressure.
  • Adjust only with appropriate tools and while monitoring a pressure gauge connected to port (4).
  • Always refer to your boiler burner manufacturer's specifications for the recommended operating pressure.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your SUNTEC oil pump.

Routine Checks:

  • Fuel Filter: Regularly check and replace the fuel filter in the supply line to prevent contaminants from entering the pump. A clogged filter can lead to reduced performance or pump damage.
  • Leak Detection: Periodically inspect all fuel line connections for any signs of leaks. Address any leaks immediately.
  • Pressure Monitoring: If equipped with a pressure gauge, regularly monitor the operating pressure to ensure it remains within the specified range.
  • Cleanliness: Keep the exterior of the pump clean and free from dust and debris.

Professional Servicing:

It is recommended to have the oil pump and burner system professionally serviced annually to ensure all components are functioning correctly and efficiently.

6. Troubleshooting

This section provides guidance on common issues you might encounter with your oil pump. For complex problems, consult a qualified technician.

Common Issues and Solutions:

ProblemPossible CauseSolution
No fuel delivery / Burner fails to igniteNo fuel in tank, clogged fuel filter, air in fuel line, faulty motor, pump not primed.Check fuel level, replace filter, bleed air from lines, check motor power, prime pump.
Low fuel pressureClogged fuel filter, air in fuel line, worn pump components, incorrect pressure adjustment.Replace filter, bleed air, inspect pump for wear (professional service), adjust pressure.
Fuel leaksLoose connections, damaged seals/gaskets, cracked housing.Tighten connections, replace seals/gaskets, replace pump if housing is cracked.
Excessive noise/vibrationAir in fuel line, loose mounting, foreign object in pump, worn bearings.Bleed air, tighten mounting bolts, inspect pump internals (professional service), replace pump.

7. User Tips

  • Always use the correct type of fuel (Diesel) as specified for the pump and burner.
  • Ensure the fuel tank is kept clean and free of water or sediment to prevent pump damage.
  • If storing the pump for an extended period, ensure it is drained of fuel and stored in a dry, clean environment.

8. Warranty and Support

For warranty information and technical support, please contact your original point of purchase or the SUNTEC authorized distributor in your region. Keep your purchase receipt and product model number (AN67A 7345-4) handy when contacting support.

This product may be eligible for free returns within 90 days, as per seller's policy. Please check with your seller for details.

© 2023 SUNTEC. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.