1. Introduction
The PowMr Grid-Tie Hybrid Solar Inverter is an all-in-one device designed to provide uninterruptible power support. It integrates the functions of a solar inverter, MPPT charge controller, and battery charger. This system efficiently combines inverter output with energy storage charging, allowing for seamless integration of clean solar energy and grid power into your battery and connected loads.
This manual provides essential information for the safe and efficient operation of your PowMr Hybrid Solar Inverter. Please read it thoroughly before installation and use.
2. Safety Information
Always observe the following safety precautions to reduce the risk of electric shock, fire, or injury:
- Read all instructions and cautionary markings on the unit and in this manual before installation and operation.
- Do not disassemble the unit. Refer servicing to qualified service personnel.
- Ensure all wiring is performed by qualified personnel and complies with local codes and regulations.
- Use insulated tools when working with the inverter.
- Verify that the input and output voltages are within the specified ranges before connecting any components.
- Keep the inverter away from flammable materials and ensure adequate ventilation.
- Do not operate the inverter in wet environments or expose it to rain.
3. Package Contents
The PowMr Hybrid Solar Inverter package typically includes:
- PowMr Hybrid Solar Inverter Unit
- User Manual
- (Optional) WiFi module and GPRS data (purchased separately for remote monitoring)
4. Product Overview
The PowMr Hybrid Solar Inverter is designed for both on-grid and off-grid applications, offering robust performance and multiple protection features.
Key Features:
- Pure Sine Wave Output: Provides clean and stable power suitable for sensitive electronics.
- High Power Output: Features two built-in AC outputs, achieving a maximum output power of 6200W for the 6.2KW model.
- Wide MPPT Voltage Range: Supports a wide MPPT range of 60-500Vdc, with a maximum PV input power of 6500W, allowing for flexible solar array configurations.
- Versatile Battery Compatibility: Compatible with various battery types including AGM, GEL, FLD, LI (Lithium-ion), SLD, and USER-defined settings.
- High Charging Current: Supports a maximum charging current of 120A (AC charger + solar charger).
- Smart Protection System: Includes multiple protection modes such as charge low/high temperature, discharge low/high temperature, discharge overcurrent, charging overcurrent, charging undervoltage, short-circuit, solar panel reverse connection, battery overvoltage, over temperature, and overload protection.
- Lithium Activation Function: Automatically activates lithium batteries when solar energy is present (after 3 seconds of setting battery type to LIB).
- Remote Monitoring: Supports remote monitoring and control via the "SMARTESS" App (optional WiFi module required).
- One-Click Restore: Allows restoring default settings with a single key press to prevent damage from incorrect configurations.
- Battery Cold Start Function: Ensures reliable startup even in cold conditions.
- Automatic Restart: Automatically restarts when AC power is restored.
- Can Work Without Battery: Provides flexibility in system design.

Figure 1: PowMr Hybrid Solar Inverter highlighting key specifications.

Figure 2: Smart Protection System illustrating multiple protection modes.

Figure 3: Inverter compatibility with various battery types (AGM, GEL, FLD, LI, SLD, USER).

Figure 4: Remote monitoring and control via the "SMARTESS" App (WiFi module sold separately).
5. Specifications
Table 1: Line Mode Specifications
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Input Voltage Waveform | Pure Sine Wave (Utility or Generator) | |
| Nominal Input Voltage | 230Vac | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
Table 2: Inverter Mode Specifications
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Rated Output Power | 4.2KW | 6.2KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 93% | |
| Overload Protection | 3s@≥150% load; 5s@101%~150% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 24Vdc | 48Vdc |
| Cold Start Voltage | 23Vdc | 46.0Vdc |
| No Load Power Consumption | 35W | 50W |
Table 3: Charge Mode Specifications
| Utility Charging Mode | ||
|---|---|---|
| INVERTER MODEL | 4.2KW | 6.2KW |
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 100A | |
| MPPT Solar Charging Mode | ||
| INVERTER MODEL | 4.2KW | 6.2KW |
| Max. PV Array Power | 6200W | 6500W |
| Nominal PV Voltage | 240Vdc | 360Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc (Battery connected) 90Vdc~450Vdc (No Battery connected) | 90Vdc~500Vdc (Battery connected) 120Vdc~500Vdc (No Battery connected) |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current (AC charger+solar charger) | 120A | |
Table 4: Grid-Tie Operation
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Nominal Output Voltage | 220/230/240VAC | |
| Feed-in Grid Voltage Range | 195-253VAC | |
| Feed-in Grid Frequency Range | 49-51±1Hz/59-61±1Hz | |
| Nominal Output Current | 18.2A | 26.9A |
| Maximum Conversion Efficiency (DC/AC) | 97% | |
Table 5: Two Load Output Power
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Full Load | 4200W | 6200W |
| Maximum Main Load | 4200W | 6200W |
| Maximum Second Load (battery model) | 1400W | 2066W |
| Main Load Cut Off Voltage | 26VDC | 52VDC |
| Main Load Return Voltage | 27VDC | 54VDC |
6. Setup and Installation
Proper installation is crucial for the performance and safety of your inverter. It is recommended that installation be performed by a qualified electrician.
6.1 Mounting the Inverter
- Choose a suitable location that is well-ventilated, dry, and away from direct sunlight, heat sources, and flammable materials.
- Ensure the mounting surface can support the weight of the inverter.
- Allow sufficient clearance around the inverter for proper airflow and cooling.
6.2 Wiring Connections
Follow the wiring diagrams provided in the full product manual for detailed connection instructions. Key connections include:
- Battery Connection: Connect the battery bank to the inverter's battery terminals. Ensure correct polarity. The inverter is compatible with Lithium-ion, Lead-acid (AGM, GEL, FLD, SLD), and user-defined battery types.
- PV Input Connection: Connect your solar panel array to the PV input terminals. Observe the maximum PV array power and open circuit voltage limits as specified in Table 3.
- AC Input Connection: Connect the AC utility grid or generator to the AC input terminals.
- AC Output Connection: Connect your loads to the main and second AC output terminals.
- Communication Port (COMM): Use this port for connecting an optional WiFi module for remote monitoring.
6.3 Battery Activation (Lithium-ion)
For Lithium-ion (LI) batteries, after connecting the solar energy source, set the battery type to LIB in the inverter settings. The lithium battery will be activated by solar energy approximately 3 seconds after this setting is applied.
7. Operating Instructions
7.1 Powering On/Off
- To Power On: Ensure all connections are secure. Turn on the battery breaker, then the PV array breaker (if applicable), and finally the AC input breaker. Press the power button on the inverter.
- To Power Off: Reverse the power-on sequence. Turn off the AC output breaker, then the AC input breaker, followed by the PV array breaker, and finally the battery breaker.
7.2 Display and Indicators
The inverter features an LCD display for monitoring system status and settings, along with an RGB LED light that indicates the current working mode:

Figure 5: RGB LED light patterns indicating working modes.
- Stationary Mode: White Light
- PV Mode: Purple Light (Solar power is actively being used)
- Battery Mode: Red Light (Power is being drawn from the battery)
- Utility Mode: Blue Light (Utility grid power is being used)
7.3 Charging Modes
The inverter supports four distinct charging modes:
- Utility First: Prioritizes charging from the utility grid.
- Solar First: Prioritizes charging from solar panels.
- Solar & Utility: Charges from both solar and utility sources simultaneously.
- Battery & Solar: Charges the battery using both battery and solar power (details may vary, refer to full manual).
7.4 Remote Monitoring (Optional)
If an optional WiFi module is installed, you can monitor and control your inverter remotely using the "SMARTESS" mobile application. Download the app from your device's app store and follow the instructions provided with the WiFi module for setup.
Video 1: Overview of the PowMr Hybrid Solar Inverter and its features.
8. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris.
- Connections: Check all electrical connections regularly for tightness and signs of corrosion.
- Environment: Ensure the installation environment remains within the recommended temperature and humidity ranges.
- Battery Health: Monitor battery voltage and health according to the battery manufacturer's recommendations.
9. Troubleshooting
If you encounter issues with your PowMr Hybrid Solar Inverter, consider the following common solutions:
- No Power Output: Check all input power sources (PV, utility, battery) and ensure they are connected and supplying power. Verify all breakers are in the ON position.
- Inverter Not Charging Battery: Check PV input voltage and current. Ensure the correct battery type is selected in the settings. Verify battery connections.
- Overload Warning: Reduce the connected load. The inverter has overload protection (e.g., 3s@≥150% load; 5s@101%~150% load).
- Over Temperature Warning: Ensure the inverter has adequate ventilation and is not exposed to excessive heat. Clean any dust from the cooling fins.
- System Malfunction/Error: If an error occurs due to incorrect settings, use the "One Click Restore Default Settings" function to revert to factory defaults. This can prevent further damage.
- Parallel Operation: This inverter is described as a single-phase output unit. If parallel operation is desired, consult the full product manual or manufacturer for compatibility and specific setup instructions, as not all models support this feature.
10. User Tips
- Battery Type Setting: When using Lithium-ion batteries, remember to set the battery type to "LIB" in the inverter's settings. The inverter will then activate the battery using solar energy after a brief delay.
- Monitor Working Mode: Pay attention to the RGB LED light on the inverter's logo. It provides a quick visual indicator of the current operating mode (White for Stationary, Purple for PV, Red for Battery, Blue for Utility).
- No Battery Operation: The inverter is capable of operating without a connected battery, offering flexibility for certain system designs.
- Remote Access: For convenient monitoring and control, consider purchasing the optional WiFi module and utilizing the "SMARTESS" app.
- Default Settings: In case of configuration errors, use the one-click restore function to revert to default settings, which can help resolve many issues without complex troubleshooting.
11. Warranty and Support
Your PowMr Hybrid Solar Inverter comes with a 24-month warranty. For warranty claims, technical support, or service inquiries, please contact your original point of purchase or the manufacturer's customer service. Ensure you have your product model and serial number available when seeking support.