KKMOON ZT-703S

Contents

ZOYI ZT703S 3-in-1 Digital Multimeter Oscilloscope Signal Generator

Model: ZT-703S | Brand: KKMOON

1. Introduction

The ZOYI ZT703S is a versatile 3-in-1 device that ingeniously integrates the functions of a digital oscilloscope, a high-precision multimeter, and a signal generator. Designed for efficiency and accuracy, it features a 3.5-inch color display for clear readings and an intuitive user interface. This manual provides essential information for the safe and effective use of your ZT703S.

2. Safety Information

Please read and understand all safety warnings and operating instructions before using this device. Failure to do so may result in injury or damage to the device.

  • Always ensure the device is properly connected and configured for the measurement you intend to perform.
  • Do not exceed the maximum input ratings for voltage and current as specified in the technical indications.
  • Use only the provided test probes and accessories.
  • The device is equipped with full-grade overload protections, built-in intelligent anti-burn chip, and double ceramic fuses. However, misuse can still cause damage.
  • Avoid using the device in wet environments or near flammable gases.
  • Do not attempt to repair or modify the device yourself. Refer to qualified service personnel.

3. Package Contents

Verify that all items are present in your package. If any items are missing or damaged, please contact your vendor.

Standard Configuration:

  • 1 x ZOYI ZT703S 3-in-1 Oscilloscope Multimeter
  • 1 x Test Probe with Accessory Set
  • 1 x Pair of Meter Pens (Red/Black)
  • 1 x USB Cable
  • 1 x Storage Bag
Standard Configuration Accessories
Figure 3.1: Standard Configuration Accessories

High Configuration (Optional):

  • 1 x ZOYI ZT703S 3-in-1 Oscilloscope Multimeter
  • 2 x Test Probes with Accessory Sets
  • 1 x Pair of Meter Pens (Red/Black)
  • 1 x USB Cable
  • 1 x Storage Bag
High Configuration Accessories
Figure 3.2: High Configuration Accessories

4. Product Overview

The ZOYI ZT703S combines a digital oscilloscope, multimeter, and signal generator in a compact, handheld design. It features a 3.5-inch HD color screen with 320*240 resolution for clear display of waveforms and measurement data.

ZOYI ZT703S Product Overview with labeled components
Figure 4.1: ZOYI ZT703S Front Panel and Ports
  • Display: 3.5-inch HD color screen (320*240 resolution)
  • Buttons: F1-F4 function keys, REC (Record), AUTO RANGE, HOLD/SAVE, MODE, MENU, and navigation keys.
  • Input Terminals: 10A current input, mA current input, COM (Common), VΩHz-||-+ (Voltage, Resistance, Frequency, Capacitance, Diode, Buzzer input).
  • Oscilloscope Probe Interfaces: CH1, CH2 (Dual Channel Oscilloscope Probe Interface).
  • USB Port: Type-C interface for data transmission and fast charging.
Front and Back View of ZOYI ZT703S
Figure 4.2: Front and Back View of ZOYI ZT703S

5. Setup

5.1 Battery Installation

The ZT703S comes with a built-in 3400mAh 18650 battery. To access the battery compartment for maintenance or replacement:

  1. Ensure the device is powered off and all probes are disconnected.
  2. Carefully remove the back cover of the device.
  3. The 18650 battery is located in the center of the circuit board.
  4. Replace the back cover securely after installation or inspection.
Internal view of ZOYI ZT703S showing battery
Figure 5.1: Internal View with Battery

5.2 Connecting Probes

Proper connection of probes is crucial for accurate and safe measurements.

  • Multimeter Probes: Connect the red meter pen to the VΩHz-||-+ terminal and the black meter pen to the COM terminal for voltage, resistance, capacitance, diode, and frequency measurements. For current measurements, connect the red meter pen to the 10A or mA terminal (depending on the expected current) and the black meter pen to the COM terminal.
  • Oscilloscope Probes: Connect the oscilloscope probes to the CH1 and/or CH2 BNC connectors at the top of the device. Ensure a secure connection.

5.3 Powering On/Off

  • Power On: Long press the 'REC' button (power button) to turn on the device.
  • Power Off: Long press the 'REC' button again to turn off the device. The device also features an 'AUTO POWER OFF' function to conserve battery.

5.4 Charging and Data Transfer

The ZT703S supports fast charging and data transfer via its USB Type-C port.

  • Charging: Connect the device to a USB power source using the provided Type-C cable.
  • Data Transfer: Connect the device to a PC using the Type-C cable to access stored waveforms and measurement data.
ZOYI ZT703S connected via USB-C for charging/data transfer
Figure 5.2: Charging/Data Transfer via USB-C

6. Operating Instructions

6.1 Multimeter Mode

The ZT703S functions as a high-precision multimeter with True RMS measurement capabilities. Use the 'MODE' button to cycle through different measurement functions.

Video 6.1: Demonstration of Multimeter, Oscilloscope, and Signal Generator Functions
  • Voltage (DC/AC): Connect probes to VΩHz-||-+ and COM. Select DCV or ACV mode using 'MODE'.
  • Current (DC/AC): Connect red probe to 10A or mA, black to COM. Select DCA or ACA mode using 'MODE'.
  • Resistance: Connect probes to VΩHz-||-+ and COM. Select Ω mode using 'MODE'.
  • Capacitance: Connect probes to VΩHz-||-+ and COM. Select capacitance mode using 'MODE'.
  • Diode/Buzzer: Connect probes to VΩHz-||-+ and COM. Select diode or buzzer mode using 'MODE'.
  • Frequency: Connect probes to VΩHz-||-+ and COM. Select Hz mode using 'MODE'.
  • AUTO RANGE: Press 'AUTO RANGE' for automatic scaling of measurements.
  • HOLD/SAVE: Short press to hold the current reading. Long press to save data.

6.2 Oscilloscope Mode

The ZT703S features a dual-channel digital oscilloscope with 50MHz bandwidth and up to 280MS/s real-time sampling rate.

Comparison of single channel vs dual channel oscilloscope display
Figure 6.1: Dual Channel Oscilloscope Display
  • Selecting Oscilloscope Mode: Use the 'MODE' button to switch to oscilloscope function.
  • Dual Channel Input: Connect probes to CH1 and CH2 for simultaneous two-channel waveform display, allowing for signal comparison and analysis.
  • Adjusting Waveforms: Use the navigation keys (up/down/left/right) to adjust parameters like vertical scale (V/div), horizontal scale (Time/div), and trigger level.
  • Trigger Modes: Select between Auto, Normal, and Single trigger modes using the appropriate menu options.
  • Advanced Functions: The oscilloscope includes features like Overclocking Mode, Afterglow Mode (Minimum, 500ms, 1s, 10s, Unlimited), and X-Y Mode for enhanced analysis.
  • Waveform Save & Screenshot: Long press the 'SAVE' button for 2 seconds to capture a screenshot of the current waveform display. Saved data can be accessed via PC connection.
More Oscilloscope Functions: Overclocking, Afterglow, MY Mode
Figure 6.2: Advanced Oscilloscope Functions

6.3 Signal Generator Mode

The built-in signal generator can output various waveforms for testing circuits.

  • Selecting Signal Generator Mode: Use the 'MODE' button to switch to signal generator function.
  • Waveform Types: Choose from Sine wave, Square wave, Sawtooth wave, Half wave, and Full wave.
  • Adjusting Parameters: Adjust the Peak-to-Peak Voltage (VPP) and Frequency (FREQ) of the output signal using the navigation keys and menu options.
Arbitrary waveforms measurement display
Figure 6.3: Arbitrary Waveforms Display

7. Specifications

Detailed technical specifications for the ZOYI ZT703S.

Multimeter Technical Indications
FunctionalityRangeResolutionAccuracy
DC Voltage V2.5000V-1000.0V0.0001V~0.1V± (0.5%+3)
DC voltage mV25.000mV-250.00mV0.001mV~0.01mV± (0.5%+3)
AC Voltage V2.5000V-750.0V0.0001V~0.1V± (0.5%+3)
AC voltage mV25.000mV-250.00mV0.001mV~0.01mV± (0.5%+3)
DC current A2.5000A-10.000A0.0001A~0.001A± (0.5%+3)
DC current mA25.000mA-250.00mA0.001mA~0.01mA± (0.5%+3)
AC current A2.5000A-10.000A0.0001A~0.001A± (0.8%+3)
AC current mA25.000mA-250.00mA0.001mA~0.01mA± (0.8%+3)
AC current frequency response40Hz~1kHz
Resistance0-250.0MΩ0.01Ω~0.1MΩ± (1%+3)
Capacitance0-99.99mF0.001nF~0.01mF± (2.0%+5)
Frequency0-999.9kHz0.01Hz~0.1kHz± (0.1%+3)
Diode√Low battery indicator√
Buzzer√Screen Backlight√
Display25000 wordsLanguageChinese/English
RangeAuto+ManualScreen Size3.5 inch
MaterialABS+TPEScreen Resolution320*240
Sampling Rate3 times/secondBattery18650 Battery*1
True RMS√Battery380g
Data Hold√Size177*89*40mm
Backlighting√
Multimeter Technical Indications Table
Figure 7.1: Multimeter Technical Indications

Oscilloscope Specifications:

  • Bandwidth: 50MHz
  • Sampling Rate: 1.5Sa/S - 280MSa/S
  • Waveform Interpolation: (sinx)x
  • Sweep Speed: 10ns/div - 20s/div
  • Time Base Accuracy: 20ppm
  • Record Length: Up to 128Kbyte
  • Channels: 2
  • Trigger: Auto, Normal, Single
  • Automatic Measurement: Period, Frequency, Peak-to-Peak, Max, Min, RMS, Duty Cycle, Number of Pulses
  • Operation Mode: Normal mode 200MSa/s, High speed mode 280MSa/s
  • Display Mode: YT, X Y, Rolling
  • Afterglow Mode: Minimum, 500ms, 1s, 10s, Unlimited

Signal Generator Specifications:

  • Waveforms: Sinewave, Squarewave, Sawtoothwave, Halfwave, Fullwave

General Specifications:

  • Operating Temperature: 0-40℃
  • Item Size: 177 * 89 * 40mm / 6.97 * 3.50 * 1.57in
  • Weight: 380g
ZOYI ZT703S Dimensions
Figure 7.2: ZOYI ZT703S Dimensions

8. Troubleshooting

If you encounter issues with your ZOYI ZT703S, please refer to the following common troubleshooting steps:

  • No Display/Device Not Turning On: Ensure the battery is charged. Connect the device to a USB power source and try again. If the issue persists, the battery may need replacement.
  • Incorrect Multimeter Readings: Check that the probes are correctly connected to the appropriate input terminals (VΩHz-||-+, 10A, mA, COM) for the selected measurement function. Verify the measurement range is suitable for the expected value, or use 'AUTO RANGE'.
  • No Oscilloscope Waveform: Ensure the oscilloscope probes are securely connected to the CH1/CH2 BNC connectors and the circuit under test. Check the trigger settings (level, mode) and adjust the vertical and horizontal scales.
  • Signal Generator Output Issues: Verify that the signal generator mode is active and the desired waveform type, VPP, and frequency are selected. Ensure the output is connected to the target circuit correctly.
  • Device Freezes or Becomes Unresponsive: Try restarting the device by long-pressing the power button. If it remains unresponsive, allow the battery to fully discharge and then recharge it.

9. Maintenance

To ensure the longevity and optimal performance of your ZOYI ZT703S, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents. Keep the screen clean and free from scratches.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.
  • Battery Care: The device uses a built-in 18650 battery. Avoid fully discharging the battery frequently. Recharge the battery when the low battery indicator appears.
  • Probe Care: Inspect test probes and oscilloscope probes regularly for any signs of wear or damage. Replace damaged probes immediately to ensure safety and accuracy.

10. User Tips

  • The ZT703S is categorized under 'DIY Supplies' specifically for 'Electrical' work, making it suitable for hobbyists and professionals in electronics.
  • Utilize the dual-channel oscilloscope feature for comparing two signals simultaneously, which is highly beneficial for analyzing phase relationships or troubleshooting complex circuits.
  • Remember to use the 'HOLD/SAVE' function to capture transient signals or important measurement data for later review or analysis on a PC.

11. Warranty and Support

The ZOYI ZT703S comes with a 12-month Manufacturer's limited Warranty for defective items (excluding items damaged and/or misused after receipt). Accessories typically come with a 3-month warranty. Please retain your proof of purchase for warranty claims.

For technical support or warranty inquiries, please contact your retailer or the manufacturer's customer service.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.