Midea CE-KFR26G/BP2DN1Y-AE, CU-KFR35G/BP2N1Y-AFBU

Contents

Midea Air Conditioning Motherboard Instruction Manual

Models: CE-KFR26G/BP2DN1Y-AE, CU-KFR35G/BP2N1Y-AFBU

Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of your new Midea air conditioning motherboard. This product is a replacement control board designed for specific Midea air conditioning units. Please read this manual thoroughly before proceeding with any installation or service.

Safety Information

  • Electrical Hazard: Always disconnect power to the air conditioning unit at the main circuit breaker before attempting any installation, maintenance, or repair. Failure to do so can result in serious injury or death.
  • Professional Installation Recommended: Installation of this motherboard requires knowledge of electrical systems and air conditioning components. If you are not qualified, please seek assistance from a certified HVAC technician.
  • Static Discharge: Electronic components are sensitive to static electricity. Handle the motherboard by its edges and avoid touching components directly. Use an anti-static wrist strap if available.
  • Component Integrity: Do not attempt to modify or repair the motherboard. Any unauthorized modifications will void the warranty and may lead to malfunction or safety hazards.

Setup and Installation

This motherboard is available in two main variants, identified by their PCB color:

  • Green Board: Model CE-KFR26G/BP2DN1Y-AE
  • White Board: Model CU-KFR35G/BP2N1Y-AFBU

Ensure you have the correct replacement board for your specific air conditioning unit model.

Identifying Your Motherboard

Green circuit board for Midea air conditioner model CE-KFR26G/BP2DN1Y-AE

Figure 1: Green circuit board (Model CE-KFR26G/BP2DN1Y-AE)

This image shows the green variant of the Midea air conditioning motherboard. It features various electronic components, including capacitors, resistors, relays, and integrated circuits, with multiple connectors for wiring harnesses. The model number CE-KFR26G/BP2DN1Y-AE is visible on the board.

White circuit board for Midea air conditioner model CU-KFR35G/BP2N1Y-AFBU

Figure 2: White circuit board (Model CU-KFR35G/BP2N1Y-AFBU)

This image displays the white variant of the Midea air conditioning motherboard. Similar to the green board, it contains a dense arrangement of electronic components and connectors. The model number CU-KFR35G/BP2N1Y-AFBU is printed on the board, indicating its specific application.

General Installation Steps

  1. Power Disconnection: Turn off the main power supply to the air conditioning unit at the circuit breaker. Verify power is off using a voltage tester.
  2. Access the Control Panel: Open the air conditioning unit's outdoor or indoor control panel to access the existing motherboard.
  3. Document Connections: Before disconnecting any wires, take clear photos or make detailed diagrams of all wire connections to the old motherboard. Pay close attention to connector types, wire colors, and their corresponding terminals.
  4. Disconnect Wires: Carefully disconnect all wiring harnesses and individual wires from the old motherboard.
  5. Remove Old Motherboard: Unscrew or unclip the old motherboard from its mounting points.
  6. Install New Motherboard: Position the new motherboard in the same location and secure it using the original screws or clips.
  7. Reconnect Wires: Using your documented photos/diagrams, carefully reconnect all wires and harnesses to the new motherboard. Ensure all connections are secure and correctly seated.
  8. Close Control Panel: Once all connections are verified, close and secure the control panel cover.
  9. Restore Power: Turn on the main power supply to the air conditioning unit at the circuit breaker.

Operating Instructions

The motherboard itself does not have direct user-operable controls. Its function is to manage the various components of the air conditioning system based on commands received from the thermostat or remote control. Once installed correctly, the air conditioning unit should resume normal operation.

  • Power On: After installation and power restoration, the air conditioning unit should power on and perform its initial self-check.
  • Functionality Check: Use your standard air conditioning thermostat or remote control to test all functions (e.g., cooling, heating, fan speeds, modes).
  • Observe for Errors: Pay attention to any unusual noises, smells, or error codes displayed on the unit's interface or thermostat.

Maintenance

Proper maintenance helps ensure the longevity and reliable performance of your air conditioning motherboard.

  • Dust Removal: Periodically, with power disconnected, carefully open the control panel and use compressed air or a soft brush to gently remove any accumulated dust from the motherboard. Dust can act as an insulator, leading to overheating, or can cause short circuits.
  • Visual Inspection: During dust removal, visually inspect the board for any signs of damage, such as burnt components, swollen capacitors, or loose connections.
  • Professional Check: It is recommended to have a qualified HVAC technician perform a comprehensive system check annually, which includes inspecting the control board.

Troubleshooting

If your air conditioning unit is not functioning correctly after motherboard replacement, consider the following troubleshooting steps:

  • No Power to Unit:
    • Check the main circuit breaker for the AC unit.
    • Verify all power connections to the motherboard are secure.
  • AC Unit Not Responding to Controls:
    • Ensure all communication wires from the thermostat/remote receiver are correctly connected to the motherboard.
    • Check the thermostat for proper function and battery life.
  • Specific Component Not Working (e.g., Fan, Compressor):
    • Verify the wiring connections for that specific component on the motherboard.
    • Consult the air conditioning unit's service manual for specific error codes or diagnostic procedures.
  • Error Codes Displayed:
    • Refer to your air conditioning unit's user manual or service manual for the meaning of specific error codes and recommended actions.

If troubleshooting steps do not resolve the issue, it is advisable to contact a qualified HVAC technician for further diagnosis and repair.

Specifications

Feature Detail
Model Numbers CE-KFR26G/BP2DN1Y-AE 17122000016838, CU-KFR35G/BP2N1Y-AFBU
Type Air Conditioner Parts (Motherboard/Control Board)
Application Home Air Conditioning Units
Certification CE
Origin Mainland China
Electric No (refers to not being an electric heater, but an electronic component)
High-concerned chemical None
Package Length 20 cm
Package Width 15 cm
Package Height 6 cm
Package Weight 0.5 kg

User Tips

  • Verify Compatibility: Before purchasing or installing, always double-check that the model number of this motherboard precisely matches the original board in your air conditioning unit. Even slight variations can lead to incompatibility.
  • Professional Assistance: If you are unsure about any step of the installation process, it is highly recommended to consult with a certified HVAC technician to avoid damage to the unit or personal injury.

Warranty and Support

For warranty claims, technical support, or further assistance, please contact the seller or the manufacturer directly. Keep your purchase records, including the order number and date of purchase, as they may be required for service.

This product is designed for durability and performance. In the unlikely event of a defect, please refer to the seller's return and exchange policy.

© 2023 Midea. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.