1. Introduction
This manual provides detailed instructions for the DC01 Infrared PM2.5 PM10 Air Quality Sensor Module. This module is designed for accurate detection of dust concentration and monitoring of fine particulate matter and haze in various environments. It offers reliable performance for integration into air quality monitoring systems and household appliances.
2. Main Characteristics
- Small size
- High sensitivity
- Good consistency
- Long-term stability
- Low power consumption
- Good anti-interference performance
3. Applications
The DC01 sensor module is suitable for a wide range of applications, including:
- Air conditioners
- Air purifiers
- Dehumidifiers
- Portable detectors
- Other household appliances
- On-board air purification systems
- Fresh air systems
- Intelligent detectors
4. Specifications
The following table details the technical specifications of the infrared particle sensor module:
| Parameter | Value |
|---|---|
| Detection type | PM0.3~PM10 |
| Detection range | 5~2500µg/m³ |
| Detection accuracy | ±20µg/m³ or ±20reading(@25±2℃,50%±10%) |
| Power-on stability time | ≤ 10s |
| Operating voltage | DC 5V±5%, Ripple less than 50mV |
| Stand-by current | ≤ 15mA |
| Output | UART |
| Input | ZH1.5mm-4P Connector |
| Operating conditions | -20℃ ~ +75℃, 0~95%RH (No condensation) |
| Storage conditions | -40℃ ~ +85℃, 0~95%RH (No condensation) |
| Life-time | 8 years since produced |
| Physical Size | 46*34*18.15mm (L*W*H) |
For a visual representation of the specifications, refer to the image below:

Image: Table summarizing the infrared particle sensor module's specifications.
5. Setup and Installation
5.1 Pin Diagram and Definitions
The sensor module features a 4-pin connector. The pin assignments and their functions are crucial for correct wiring:

Image: Diagram showing the pin layout of the DC01 sensor module, indicating Pin1 and Pin4.
| Pin number | Pin name definition | Pin function description | Pin electrical characteristics |
|---|---|---|---|
| Pin 1 | GND | power negative | no reverse protection |
| Pin 2 | VCC | power positive (+5V) | |
| Pin 3 | RXD | RXD pin of the module UART interface | TTL level @ 5V |
| Pin 4 | TXD | TXA pin of the module UART interface | open-circuit output, internal pull-up resistor connected to the power positive |
5.2 Application Circuit
Connect the DC01 Dust Sensor to your Host MCU as shown in the diagram below. Ensure all connections are secure and correctly aligned to prevent damage to the module or MCU.

Image: Wiring diagram illustrating the connection between the Dust Sensor D01 and a Host MCU.
- Dust Sensor GND (Pin 1) connects to HOST MCU GND.
- Dust Sensor VCC (Pin 2) connects to HOST MCU VCC (+5V).
- Dust Sensor RXD (Pin 3) connects to HOST MCU TXD.
- Dust Sensor TXD/PWM (Pin 4) connects to HOST MCU RXD/IO.
6. Operating Instructions
The DC01 sensor module provides data output via UART and PWM interfaces.
6.1 UART Configuration and Data Output
The UART interface provides serial data output with the following parameters:
- Baud rate: 9600bps
- Check bit: None
- Stop bit: 1 bit
- Data bit: 8
A frame of serial output data includes 4 bytes, formatted as follows:

Image: Table detailing the 4-byte UART data format, including Characteristic Byte, Byte 1 (DATAH), Byte 2 (DATAL), and Check Byte (SUM).
- Characteristic byte: Fixed value 0xA5.
- Data byte: DATAH is the high 7 bits of the concentration value, and DATAL is the low 7 bits of the concentration value.
- Check byte: The low 7 bits of the sum of all bytes before the check byte.
Serial data conversion formula: Concentration value = DATAH (bit[6:0])*128 + DATAL (bit[6:0])
Note: The PM2.5 dust concentration value obtained from the dust sensor needs to be calibrated with a K value coefficient based on the TSI instrument's photometric method. It is generally recommended to use 0.4.
Example: If the serial output is 4 bytes of data: 0*A5 0*01 0*2C 0*52, then DATAH = 0*01 = 1, DATAL = 0*2C = 44. Concentration value = 1*128 + 44 = 172 µg/m³.
6.2 PWM Output
The sensor outputs a PWM signal through the PWM pin (Pin 4). The PWM cycle is 1.2 seconds. The dust concentration value is calculated based on the width of the low-level pulse.

Image: Text describing the PWM output characteristics and calculation method for the DC01 sensor.
Example: If the low-level pulse width is 50ms, the corresponding dust concentration is 50µg/m³.
The concentration output range is from 5µg/m³ to 1000µg/m³. The concentration value has undergone software filtering internally, and the fluctuation range is relatively small. Note: Due to individual differences in products, the maximum output value is within the range of 990-1010µg/m³.
7. Maintenance
To ensure optimal performance and longevity of your DC01 sensor module, consider the following maintenance guidelines:
- Keep Clean: Ensure the sensor's air inlet and outlet are free from dust, debris, or obstructions. Gently clean the exterior with a soft, dry cloth if necessary.
- Environmental Conditions: Operate and store the module within the specified operating and storage conditions to prevent damage. Avoid exposure to extreme temperatures, high humidity (especially condensation), and corrosive gases.
- Handle with Care: Avoid dropping or subjecting the module to strong impacts, which could damage internal components.
- Power Supply: Use a stable DC 5V power supply with ripple less than 50mV as specified to prevent erratic readings or damage.
8. Troubleshooting
If you encounter issues with your DC01 sensor module, consider the following troubleshooting steps:
- No Output/Incorrect Readings:
- Verify power supply: Ensure the module is receiving a stable 5V DC power.
- Check wiring: Confirm all pins (GND, VCC, RXD, TXD/PWM) are correctly connected to your MCU according to the application circuit diagram.
- UART settings: Double-check that your MCU's UART communication settings (baud rate, check bit, stop bit, data bit) match the sensor's specifications (9600bps, None, 1, 8).
- Sensor obstruction: Ensure the sensor's air pathways are not blocked.
- Fluctuating Readings:
- Environmental stability: Ensure the environment around the sensor is stable and free from sudden air currents or large temperature/humidity changes.
- Power supply noise: Check for excessive ripple or noise in the power supply.
- Calibration: Remember that PM2.5 values may require calibration with a K value coefficient.
- Module Not Powering On:
- Check power connections: Ensure VCC and GND are correctly connected and receiving power.
- Inspect for damage: Look for any visible physical damage to the module or connector.
If the problem persists after following these steps, please contact your supplier for further assistance.
9. Product Appearance and Size
The physical dimensions of the DC01 sensor module are provided in the diagram below. All dimensions are in millimeters (mm) with a tolerance of ±0.5mm.

Image: Detailed engineering drawing showing the length, width, height, and mounting hole dimensions of the DC01 sensor module.
Note: No tolerance specified: ±0.5mm, mounting holes on both ends can be removed.