1. Introduction and Overview
The Mestek CM86B is a professional True-RMS 1000A AC/DC Current Clamp Meter designed for accurate electrical measurements. This versatile instrument can measure AC/DC current, AC/DC voltage, resistance, capacitance, frequency, and temperature. It features a large 42mm jaw for cable measurement and an optional iFlex flexible current clamp that extends AC current measurement up to 3000A. With its auto-ranging capability, HD backlight, and various advanced functions like Inrush measurement and Non-Contact Voltage (NCV) detection, the CM86B is suitable for a wide range of applications in electric power, communication, railway, construction, oilfield, metering, scientific research, and industrial environments.

2. Package Contents
Upon opening the package, please verify that all items listed below are present and in good condition:
- 1 x Mestek CM86B Clamp Meter Device
- 1 x Cloth Bag
- 1 x Packing Box
- 1 x Thermocouple (for temperature measurement)
- 1 x Set of Test Leads (red and black)
- 1 x User Manual
- 1 x iFlex Flexible Current Clamp (if selected with this option)

3. Product Features and Functions
The Mestek CM86B is equipped with a comprehensive set of features for various electrical measurement tasks:
- iFlex Flexible Current Clamp: Extends AC current measurement range up to 3000A.
- Auto Voltage Low Impedance (Auto-V LoZ): For accurate voltage measurements without ghost voltages.
- Inrush Measurement: Captures motor startup current time.
- VFD (Variable Frequency Drive) Measurement: For accurate measurements on variable frequency signals.
- AC/DC Current Measurement: Up to 1000A with the main clamp, up to 3000A AC with iFlex.
- AC/DC Voltage Measurement: Up to 750V AC and 1000V DC.
- Resistance Measurement: Up to 60MΩ.
- Capacitance Measurement: Up to 60mF.
- Temperature Measurement: Measures from -20°C to 1000°C (-4°F to 1832°F) using the included thermocouple.
- Diode Test: Checks diode functionality.
- Continuity Test: With audible beep for quick circuit checks.
- Firewire Identification (Live Wire Detection): Identifies live wires using the red test lead.
- NCV (Non-Contact Voltage) Detection: Detects AC voltage without physical contact.
- Data Zero: Clears DC current readings to zero before measurement.
- Data Hold: Freezes the displayed reading.
- MAX/MIN Value: Records maximum and minimum readings.
- Auto Ranging: Automatically selects the correct measurement range.
- Flashlight: Built-in for illuminating dark work areas.
- HD Backlight: Ensures clear display readability in various lighting conditions.
- Auto Power-Off: Conserves battery life.
- Low Battery Alert: Indicates when batteries need replacement.
- Frequency Measurement: Measures frequency up to 400Hz.


4. Setup
4.1 Battery Installation
The CM86B requires 3x1.5V AAA batteries for operation. To install or replace batteries:
- Ensure the meter is powered off.
- Locate the battery compartment on the back of the meter.
- Use a screwdriver to open the battery cover.
- Insert three 1.5V AAA batteries, observing the correct polarity (+/-).
- Replace the battery cover and secure it with the screw.
4.2 Connecting Test Leads
For voltage, resistance, capacitance, diode, and continuity measurements:
- Insert the red test lead into the "INPUT" terminal.
- Insert the black test lead into the "COM" terminal.
4.3 Connecting iFlex Flexible Current Clamp
To extend AC current measurement capabilities:
- Ensure the meter is powered off.
- Plug the iFlex flexible current clamp connector into the dedicated iFlex input port on the meter.
- Twist the connector to secure it.
5. Operating Instructions
Before operating, ensure the meter has sufficient battery power and test leads/probes are correctly connected for the desired measurement.
5.1 Power On/Off and Auto Ranging
- Rotate the function selection knob from "OFF" to any desired measurement function to power on the meter.
- The meter features auto-ranging, automatically selecting the appropriate range for most measurements.
- To power off, rotate the function selection knob back to "OFF". The meter also has an auto power-off feature to conserve battery.
5.2 DC Current Measurement
- Rotate the function knob to the DC current (A) position.
- Open the clamp jaws and enclose a single conductor.
- Read the DC current value on the display.
- Important: The ZERO clearing function is only used for DC current. Due to magnetic fields, DC current readings can be affected. Long press the "ZERO" button to reset the reading to zero before measurement for accuracy.
- Note: When measuring DC current below 0.4A, the signal input on the screen may flicker. Readings of 0.5A or greater will not flicker.


5.3 AC Current Measurement
- Rotate the function knob to the AC current (A) position.
- Open the clamp jaws and enclose a single conductor.
- Read the AC current value on the display.
- For currents exceeding 1000A (up to 3000A), connect the iFlex flexible current clamp and use it to encircle the conductor.

5.4 AC/DC Voltage Measurement
- Connect the test leads as described in Section 4.2.
- Rotate the function knob to the ACV or DCV position.
- Touch the test probes to the circuit points where voltage is to be measured.
- Read the voltage value on the display.
- For AC voltage, short press the "VFD" key to enter the variable frequency measurement function for accurate readings on VFD circuits.

5.5 Resistance Measurement
- Connect the test leads as described in Section 4.2.
- Rotate the function knob to the Ω (Resistance) position.
- Ensure the circuit under test is de-energized.
- Touch the test probes across the component to measure resistance.
- Read the resistance value on the display.
5.6 Capacitance Measurement
- Connect the test leads as described in Section 4.2.
- Rotate the function knob to the F (Capacitance) position.
- Ensure the capacitor is discharged before measurement.
- Touch the test probes across the capacitor terminals.
- Read the capacitance value on the display.
5.7 Diode Test and Continuity Test
- Connect the test leads as described in Section 4.2.
- Rotate the function knob to the Diode/Continuity position.
- Press the "SEL" button to switch between Diode Test and Continuity Test.
- For Diode Test: Place probes across the diode. The display will show the forward voltage drop.
- For Continuity Test: Place probes across the circuit. An audible beep indicates continuity.
5.8 Temperature Measurement
- Ensure the meter is powered off.
- Plug the thermocouple into the "INPUT" and "COM" terminals, observing polarity.
- Rotate the function knob to the °C/°F (Temperature) position.
- Place the thermocouple tip on or in the object whose temperature is to be measured.
- Press the "SEL" button to switch between Celsius and Fahrenheit units.

5.9 NCV (Non-Contact Voltage) Detection
- Rotate the function knob to the NCV position.
- Bring the NCV sensor head of the instrument close to the circuit or conductor under test.
- The meter will emit different alarm prompts (audible and visual) based on the detected voltage intensity.

5.10 Live Firewire Recognition
- Connect the red test lead to the "INPUT" terminal.
- Rotate the function knob to the "Live" position.
- Insert the red test lead into the neutral or live wire port.
- If a live wire is detected, the buzzer will sound an alarm. If it is a neutral wire or ground wire, there will be no response.

5.11 Inrush Current Measurement
- Rotate the function knob to the AC or DC current (A) gear.
- Short press the "INRUSH" button to enter Inrush measurement mode.
- Measure the maximum current at the moment the machine or motor starts.

5.12 Data Hold
- Press the "HOLD" button to freeze the current reading on the display.
- The "H" symbol will appear on the screen and flash every 3 seconds.
- Press the "HOLD" button again to cancel data hold and resume live readings.

5.13 HD Backlight and Flashlight
- Press the backlight button (often combined with the flashlight button) to turn on the display backlight for improved visibility in dim conditions.
- Long press the same button to activate the built-in flashlight.
- Press again to turn off the backlight/flashlight.

6. Maintenance
- Cleaning: Use a soft, damp cloth to clean the meter's exterior. Do not use abrasive cleaners or solvents.
- Storage: When not in use for extended periods, remove the batteries to prevent leakage. Store the meter in its cloth bag in a cool, dry place, away from direct sunlight and extreme temperatures.
- Battery Replacement: Replace batteries promptly when the low battery indicator appears on the display to ensure accurate measurements.
- Calibration: For professional use, periodic calibration by qualified personnel is recommended to maintain accuracy.
7. Troubleshooting
- No Display/Faint Display:
- Check battery level. Replace with fresh 1.5V AAA batteries if low.
- Ensure batteries are installed with correct polarity.
- Inaccurate DC Current Readings:
- Perform the "Data Zero" function by long-pressing the ZERO button before measurement, especially if affected by magnetic fields.
- Ensure only a single conductor is enclosed by the clamp jaws.
- Display Flickering (DC Current < 0.4A):
- This is normal behavior for DC currents below 0.4A. Readings of 0.5A or greater will be stable.
- No Response from Live Firewire Recognition:
- Ensure the red test lead is correctly inserted into the "INPUT" terminal and the function knob is set to "Live".
- Verify the wire being tested is indeed a live wire.
8. Specifications (CM86B Model)
| Parameter | Value |
|---|---|
| Model | CM86B |
| Auto Range | Yes |
| Highest Input Voltage (COM/INPUT) | AC 750V / DC 1000V |
| AC Voltage Range | 0~750V |
| DC Voltage Range | 0~1000V |
| Resistance Range | 0~60MΩ |
| Capacitance Range | 0~60mF |
| AC Current Range | 0~1000A (up to 3000A with iFlex) |
| DC Current Range | 0~1000A |
| Temperature Measurement | -20~1000°C / -4~1832°F |
| Frequency Range | 40~400Hz |
| Inrush Current | 1000A |
| Backlight | Yes |
| Maximum Display Value | 5999 counts |
| Over Range Display | 0L or -0L |
| Sampling Time | About 3 times / second |
| Power Supply | 3x1.5V AAA batteries |
| VFD/NCV/Live/Diode | Yes |
| On-off Test / Buzzer | Yes |
| Data Hold | Yes |
| Data Zero | Yes |
| Dimensions | 250*85*45mm |
| Jaw Size | 42mm |
| iFlex Flexible Clamp Length | 1.8m |
| iFlex Flexible Clamp Dimensions | 7.5mm |
| Weight | About 368g (without battery) |

9. User Tips
- Always perform the "Data Zero" function before measuring DC current to ensure accuracy, as magnetic fields can affect readings.
- When measuring AC voltage in circuits with variable frequency drives (VFDs), remember to short press the "VFD" key for precise measurements.
- The NCV feature is excellent for quickly checking for live voltage without direct contact, providing an audible and visual alert.
- The data hold function is useful for recording readings in hard-to-reach areas; the 'H' symbol will flash to remind you it's active.
- The large 42mm jaw allows for easy clamping around thicker cables, making it versatile for various applications.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact information provided in your product packaging or on the official Mestek website. Keep your purchase receipt as proof of purchase for any warranty claims.