1. Introduction
Thank you for selecting and using our SUSWE SU-300 series frequency converter products. This manual provides essential information for the correct and safe use of the product. Please read it carefully before installation, operation, or maintenance, and keep it for future reference.
The SU-300 series is a high-performance vector universal frequency converter designed for various motor control applications, offering stable quality, reduced loss, and low frequency with large torque.

2. Safety Information and Precautions
Always observe the following safety guidelines to prevent injury, damage, or malfunction.
2.1 Danger
- Before wiring, confirm that the input power has been cut off to avoid electric shock and fire.
- Wiring operations must be performed by qualified electrical engineering professionals.
- The grounding terminal must be reliably grounded (special type 3 grounding for 380V level) to prevent electric shock and fire.
- After connecting the emergency stop terminal, ensure its action is effective to prevent injury.
- Do not touch the output terminals directly. The frequency converter's output terminal is directly connected to the motor. Do not short circuit between output terminals to avoid electric shock and short circuit.
- Before powering on, ensure the terminal cover is properly installed. When disassembling the outer cover, disconnect the power supply first to avoid electric shock.
- Cut off the power and wait for 5 to 8 minutes for the remaining power in the machine to be completely discharged before proceeding with inspection and maintenance. There is a risk of residual voltage on electrolytic capacitors.
- Non-professional technical personnel are not allowed to carry out inspection and maintenance work to avoid electric shock.
2.2 Attention
- Confirm that the incoming line power supply voltage is consistent with the rated input voltage of the frequency converter to avoid injury and fire.
- Connect the braking resistor or braking unit according to the wiring diagram to prevent fire.
- Use a screwdriver and wrench with the specified torque to tighten the terminals to prevent fire.
- Do not connect the input power cord to the output U/V/W terminals. Applying voltage to the output terminal can cause internal damage to the frequency converter.
- Do not remove the front panel cover; only remove the terminal cover when wiring. Removing the front panel cover may cause internal damage to the frequency converter.
- Any injury or loss caused by operation not according to these requirements is not the responsibility of the manufacturer.
3. Technical Specifications
The SU-300 series frequency converter offers robust performance and versatile control options.
3.1 Product Parameters

| Feature | Specification |
|---|---|
| Rated Voltage, Frequency | Three-phase (G3 series) 380V; 50/60HZ, Three-phase (G2 series) 220V; 50/60HZ |
| Allowable Voltage Range | Three-phase (G3 series) 320V~460V, Three-phase (G2 series) 190V~250V |
| Output Voltage | G3 series: 0-380V, G2 series: 0~220V |
| Control Method | V/F control, simple vector control, advanced vector control, torque control |
| Output Frequency | V/F control, simple vector control: 0.0~999.9HZ; Advanced vector control and torque control: 0.5-300.0HZ |
| Overload Capacity | 110% long-term, 150% 1 minute, 180% 5 seconds |
| Frequency Setting Resolution | Analog input: 0.1% of maximum output frequency; Digital input: 0.1HZ |
| Frequency Accuracy | Within 0.2% of the maximum output frequency; Set output frequency within 0.01% |
| Torque Increase | Manual setting: 0.0-30.0% of rated output; Automatic lifting based on output current and motor parameters |
| Starting Torque | 100% rated torque at 5.0Hz (V/F control); 150% rated torque at 1.0Hz (vector control) |
| Cooling Method | Air cooled, with fan control |
| Installation Method | Wall mounted, cabinet mounted |
| Weight | 1-1.5kg |
| Size | 11.3*16*9.5cm (approx.) |
3.2 Model Naming Rules
The SU-300 series models follow a specific naming convention:
- SU300: Series designation.
- Power Grade: e.g., 0R75=0.75KW, 1R5=1.5KW, 2R2=2.2KW.
- Voltage Grade:
- G1 = Input single-phase 220V, output three-phase 380V
- G2 = Input single-phase 220V, output three-phase 220V
- G3 = Input three-phase 380V, output three-phase 380V

4. Installation and Wiring
Proper installation and wiring are crucial for the safe and efficient operation of the frequency converter.
4.1 Guide Rail Installation
The SU-300 series supports a convenient one-button guide rail installation method.

4.2 Basic Operation Wiring
The wiring of the frequency converter is divided into the main circuit and the control circuit. Users must connect the wiring circuit correctly according to the provided diagrams.



4.3 Wiring Precautions
- When replacing the motor, the input power of the frequency converter must be cut off.
- The motor or power supply can only be switched when the frequency converter stops outputting.
- To minimize electromagnetic interference, consider installing surge absorption devices when using electromagnetic contactors and relays close to the frequency converter.
- Do not connect the AC input power to the output terminals U, V, W of the frequency converter.
- The external control line of the frequency converter needs to be equipped with isolation devices or shielded wires.
- Input command signal wiring should be routed separately, away from the main circuit wiring.
- When the carrier frequency is less than 4KHz, the maximum distance between the frequency converter and the motor should be within 50 meters. For carrier frequencies greater than 4KHz, this distance should be reduced, and wiring should preferably be laid in a metal tube.
- When installing peripheral devices (filters, reactors, etc.), measure the insulation resistance to ground with a 1000 volt megohmmeter to ensure it is not lower than 4 megohms.
- Do not install phase capacitors or resistance capacitance absorption devices at the output terminals U, V, and W.
- If frequent starting is required, do not turn off the power. Use the COM/RUN control terminal for start/stop operation to avoid damaging the rectifier bridge.
- The grounding terminal G must be reliably grounded (impedance below 100 Ω) to prevent leakage.
- When wiring the main circuit, follow national electrical regulations for wire diameter specifications.
5. Operation and Display
The operation panel allows for functional parameter modification, monitoring of working status, and control of operation (start, stop).

5.1 Function Indicators
- RUN: Lamp extincted means the frequency converter is stopped; lamp lighting means it is running.
- F/R: Forward and reverse running indicator lamp; lamp lighting means it is in forward status.
- TC: Fault indicator light; flashing indicates a fault state.
5.2 Unit Indicators
- Hz: Frequency unit
- A: Current unit
- V: Voltage unit
5.3 Digit Display Area
The 5-bit LED display shows the setting frequency, output frequency, various monitor data, and alarm codes.

5.4 Keyboard Button Description
| Key | Key Name | Function |
|---|---|---|
| PRG | Programming Key | Enter or exit Level I menu. |
| ENTER | Confirm Key | Enter menu levels, confirm setting parameters. |
| ▲ | Increment Key | Progressively increase data or function code. |
| ▼ | Decrement Key | Progressively reduce data or function code. |
| SHIFT | Shift Key | Select display parameters in stop/run status; select parameter modification bit. |
| RUN | Running Key | Used for running operation in keyboard control mode. |
| STOP/REST | Stop/Reset Key | Stop running operation; reset operation at failure alarm status (characteristics depend on P7-02). |
| M-FUNC | Multiply Functions Select Key | Process function shift selection according to F2.33. |
6. Function Parameters
The SU-300 series frequency converter offers a wide range of configurable parameters to adapt to various applications. Parameters can be modified in any state (○), cannot be modified during operation (X), are actual detection parameters (●), or are manufacturer-only parameters (●).
6.1 F0 Group - Basic Running Parameters
This group contains fundamental parameters for basic operation.
| Code | Name | Description | Setting Range | Factory Setting | Alter |
|---|---|---|---|---|---|
| F0-00 | Function Macro | 0: Universal mode, 1: Single pump constant pressure water supply mode, 4: Engraving machine mode | 0~10 | 0 | X |
| F0-01 | Motor Control Mode | 0: V/F control, 1: Advanced V/F control, 2: Simple vector control, 3: Advanced vector control, 4: Torque control | 0~4 | 0 | X |
| F0-02 | Run Command Source Selection | 0: Keypad, 1: Terminal, 2: Communication | 0~2 | 0 | ○ |
| F0-06 | Lower Frequency Limit | The operating frequency cannot be lower than this frequency. | 0.0~Upper frequency limit | 0.0Hz | X |
| F0-10 | Acceleration Time | Time for the inverter to accelerate from zero frequency to the maximum output frequency. | 0.1~999.9S | Model Specific | ○ |
For a complete list of parameters and their detailed descriptions, please refer to the full PDF manual available at User manual (PDF).
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your frequency converter.
7.1 General Maintenance
- Keep the unit clean and free from dust and debris.
- Ensure proper ventilation around the unit. The SU-300 series features a silent fan for efficient cooling.
- Periodically check all wiring connections for tightness and signs of wear.
- Only qualified personnel should perform maintenance tasks.

7.2 Protection Functions
The SU-300 series is equipped with six protection functions to ensure safe operation:
- Overcurrent protection
- Overvoltage protection
- Undervoltage protection
- Overload protection
- Power module protection
- Overtemperature protection

8. Troubleshooting
This section provides solutions for common issues encountered during the operation of the frequency converter.
| Fault Phenomenon | Possible Causes | Corrective Actions |
|---|---|---|
| No Display on Keypad | Power failure, missing phase in input power supply, incorrect wiring. | Check for power, phase, and wiring. |
| Motor Does Not Rotate (No Display, but Internal Charge Indicator is Lit) | Keypad wiring/connectors issue, switching power supply malfunction, damaged starting resistor, faulty voltage regulator. | Check keypad wiring, measure internal control power supply voltage, check starting resistor and voltage regulator. |
| Motor Humming | Motor load is too heavy. | Reduce the load. |
| Motor Doesn't Accelerate/Decelerate Smoothly | Inappropriate acceleration/deceleration time setting, current limit value too low, overvoltage protection during deceleration, inappropriate carrier frequency setting, heavy load or oscillation. | Increase acceleration/deceleration time, increase current limit, adjust carrier frequency, reduce load. |
| Motor Rotation Direction is Opposite | Incorrect phase sequence of output terminals U, V, W. | Adjust the phase sequence of the output terminals U, V, W. |
| E0C1 Overcurrent during Acceleration | Short acceleration time, inverter power too small, improper V/F curve or torque boost setting. | Increase acceleration time, use higher power inverter, adjust V/F curve or torque boost. |
| EHU1 Overvoltage during Acceleration | Abnormal input voltage, restarting a rotating motor. | Check input power, set to start after DC braking. |
| EPLI Output Phase Loss Protection | Output phase loss on U, V, W. | Check output wiring. |
For a comprehensive list of fault codes and troubleshooting steps, please refer to the full PDF manual available at User manual (PDF).
9. User Tips
- External Panel Compatibility: If you require an external panel, ensure it is specifically designed for SU300 frequency converters and is compatible with your unit. Note that this product is only applicable to frequency converters purchased from our store.
- Power Matching: When selecting a frequency converter, ensure its power rating matches your motor's requirements to avoid issues like motor humming or inability to accelerate/decelerate smoothly.
- Wiring Verification: Double-check all wiring, especially for single-phase to three-phase conversions, to ensure correct input and output connections. Incorrect wiring can lead to malfunction or damage.
10. Warranty and Support
The SUSWE SU-300 series frequency converter comes with a 1-year warranty. For any technical support, questions, or service inquiries, please contact our customer service team. Our professionals are dedicated to providing the best service.
For detailed parameters and further assistance, please refer to the complete user manual (PDF) or contact our support team.
User manual (PDF): View/Download PDF