1. Introduction
The Hantek TO1000 Series represents a new generation of multi-functional, full touch screen oscilloscopes designed for portability and versatility. Featuring a thin body and light weight, these devices are easy to carry and incorporate a unique hanging design for hands-free operation. Built with anti-falling and anti-seismic durability, the TO1000 Series integrates an oscilloscope, multimeter, signal generator, and spectrum analyzer into a single unit. It boasts a super large capacity battery for long endurance and supports fast charging via Type-C.
Key Features:
- Multi-touch large screen with 800x480 resolution, offering a friendly and easy-to-use UI for a good interaction experience.
- Standard configuration of 2-channel oscilloscope, with a maximum bandwidth of up to 250MHz and a maximum sampling rate of 1GSa/s, featuring 8M large storage.
- High-precision multimeter with data recording, storage, trend chart, and statistical analysis functions.
- Built-in signal generator with a variety of arbitrary waveforms, offering a highest output frequency of 25MHz.
- One-key waveform storage for convenient and fast data saving.
- Suspension foot design allows for multi-angle adjustment, providing anti-falling and anti-seismic protection.
- Built-in super large capacity lithium battery ensures long endurance, with standby time up to half a year.
- Standard 18W charger supports Type-C fast charging, allowing shared charging equipment with mobile phones.
Video: Overview of the Hantek TO1000 Series Oscilloscope's features and design.
2. Setup
2.1 Package Contents
Verify that all items are present in your package. The contents vary slightly depending on the model (C or D series).

Image: Two-channel accessories list for Hantek TO1000 Series.
TO1152C/TO1202C/TO1252C Standard Configuration:
- Oscilloscope host x1
- Instrument Pack x1
- Probe x1
- Alligator clip line x1
- Multimeter Pen x1
- 18W adapter x1
- Type-C charging line x1
TO1152D/TO1202D/TO1252D Standard Configuration:
- Oscilloscope host x1
- Instrument Pack x1
- Probe x1
- Alligator clip line x2
- Multimeter Pen x1
- 18W adapter x1
- Type-C charging line x1
2.2 Charging the Device
The device is equipped with a large capacity lithium battery. Use the provided 18W adapter and Type-C charging cable to charge the oscilloscope. A full charge provides long endurance, with standby time up to half a year. The Type-C port allows for convenient charging, compatible with many mobile phone chargers.

Image: Illustration of the 18W fast charge feature and battery compartment.
The TO1112 series is equipped with a battery compartment for 2 batteries (2600mAh*2 = 5200mAh capacity). The four-battery version of the TO1112 Series has a 10400mAh capacity (2600mAh*4). Other series configurations also feature 4 batteries for 10400mAh capacity.
2.3 Physical Design and Interface
The TO1000 Series features a robust design with four-corner protection, making it anti-fall and anti-seismic. It has a 7-inch full touch screen with 800x480 resolution and an English UI interface for intuitive operation.

Image: Solid appearance design with dimensions and interface labels.
- Dimensions: Length: 248MM, Width: 176MM, Height: 54MM
- Display: 7" touchscreen display, 800*480 resolution
- Ports: USB (U disk memory interface), Charging interface (Type-C)
The unique hanging design allows for flexible placement, including on a table using the kickstand or hanging on a partition window, freeing your hands during use.

Image: Hanging legs available, showing flexible placement options.
The device features an all-English interface, making it simple and intuitive for global users, including beginners.

Image: All English interface for ease of use.
3. Operating Instructions
3.1 Oscilloscope Function (OSC)
The oscilloscope function allows for detailed waveform analysis. The touch screen interface provides a convenient way to interact with the device, similar to a smartphone.

Image: Full touch screen operation of the oscilloscope.
3.1.1 X-Y Mode
The X-Y mode is used for Lissajous measurements to determine the phase difference between two sine-wave signals of the same frequency.

Image: The X-Y mode for phase difference measurements.
3.1.2 Roll Mode
In Roll mode, the waveform rolls from right to left. The horizontal range is 100ms to 100s, typically used to observe waveforms below 5Hz. This mode provides a real-time display without dead zones or data loss. The waveform cannot be displayed stably, and there is no trigger concept, meaning low probability signals cannot be automatically identified.

Image: ROLL rolling mode display.
3.1.3 Trigger Functions
The device offers 7 trigger types, making it easier to capture instantaneous and abnormal signals. These include Single, Automatic, Edge, Pulse, Video, Slope, and Timeout triggers.

Image: Seven trigger types for capturing various signals.
3.1.4 Measurement Parameters
The oscilloscope supports as many as 42 kinds of voltage parameters, providing intuitive display and free formula calculation.

Image: 42 kinds of measurement parameters available.
3.1.5 Mathematical Operations and FFT Spectrum
The device can perform mathematical operations such as addition (+), subtraction (-), multiplication (*), and division (/). The FFT (Fast Fourier Transform) function converts the time domain into the frequency domain, allowing for analysis of the frequency components of a signal.

Image: Mathematical operations and FFT spectrum analysis.
3.2 Multimeter Function (DMM)
The C and D series models include an optional multimeter function. This allows for measurements of AC and DC voltage, current, resistance, capacitance, diode, and on-off continuity. It also features a data recording function to monitor and record changes over time, generating trend charts or allowing data export.

Image: Optional multimeter function in use.
3.3 Signal Generator Function (AFG)
The D series models include an optional signal generator function. This allows the oscilloscope and signal generator to be used simultaneously. It features a maximum output frequency of up to 25MHz, 12-bit high resolution, and a 200MS/s high sampling rate. It supports a variety of arbitrary waves, AM/FM modulation, and allows switching between high and low resistance outputs.

Image: Optional signal generator function interface.
3.4 Data Storage
The device supports an 8G-U disk for data storage. You can save reference waveforms, CSV waveforms, waveform pictures, settings, and use a one-click screensaver function to save directly to the U disk.

Image: Data storage function, saving to USB flash drive.
3.5 Computer Software
The Hantek TO1000 Series can communicate with a computer via its USB interface. Measurement waveforms can be easily operated and analyzed using the dedicated computer software. The software is primarily used for D series models to edit and output arbitrary waves.

Image: Computer software interface for waveform operation.
4. Maintenance
- Keep the device clean and free from dust and moisture. Use a soft, dry cloth for cleaning the screen and casing.
- Avoid exposing the device to extreme temperatures or direct sunlight for prolonged periods.
- Store the device in its instrument pack when not in use to protect it from physical damage.
- Ensure the Type-C charging port is free of debris before charging.
5. Troubleshooting
5.1 Device Not Powering On
- Ensure the device is fully charged. Connect it to the 18W adapter and Type-C charging cable and allow it to charge for at least 30 minutes.
- Check the charging cable and adapter for any damage. Try using a different compatible Type-C cable and adapter if available.
5.2 No Waveform Display
- Verify that the probes are correctly connected to the device and the circuit under test.
- Check the probe settings (e.g., 1X/10X attenuation) on both the probe and the oscilloscope to ensure they match.
- Adjust the vertical scale (Volts/Div) and horizontal scale (Time/Div) to an appropriate range for the signal being measured.
- Ensure the trigger settings are correctly configured. Try setting the trigger mode to "Auto" initially.
5.3 Multimeter Readings are Inaccurate
- Ensure the multimeter pens are securely connected to the correct input jacks (V/Ω/C, COM, mA, A).
- Select the correct measurement function (voltage, current, resistance, etc.) and range.
- Verify that the circuit is properly connected and powered for the measurement being taken.
6. Specifications
6.1 Model Selection Table

Image: TO1000 Series Model Selection Table.
| Models | Channel | Bandwidth | Sampling rate | Storage depth | Signal Source | Multimeter |
|---|---|---|---|---|---|---|
| TO1152C | 2 CH | 150 MHz | 1GSa/S | 8M | - | YES |
| TO1202C | 2 CH | 200 MHz | 1GSa/S | 8M | - | YES |
| TO1252C | 2 CH | 250 MHz | 1GSa/S | 8M | - | YES |
| TO1152D | 2 CH | 150 MHz | 1GSa/S | 8M | 25 MHz | YES |
| TO1202D | 2 CH | 200 MHz | 1GSa/S | 8M | 25 MHz | YES |
| TO1252D | 2 CH | 250 MHz | 1GSa/S | 8M | 25 MHz | YES |
Battery Parameters: Four batteries, 3.7V 2600mAh*4, Four-section parallel.
Battery Life: Use for about 7-8 hours. Supports plug-in power bank.
6.2 Oscilloscope Parameters

Image: Oscilloscope Basic Parameters Table (Part 1).

Image: Oscilloscope Vertical Parameters Table (Part 2).

Image: Oscilloscope Trigger and Measuring Function Parameters Table (Part 3).

Image: Oscilloscope Trigger and Measuring Function Parameters Table (Part 4).

Image: Oscilloscope Auto Measure, Math Operations, FFT, and Storage Parameters Table.
6.3 Multimeter Parameters (Only C and D series standard)

Image: Multimeter Parameters Table (Part 1).

Image: Multimeter Parameters Table (Part 2).
6.4 Arbitrary Wave Generator Parameters (Only D series standard)

Image: Arbitrary Wave Generator Parameters Table.
6.5 Certifications
The Hantek TO1000 Series oscilloscopes are CE and EMC certified, ensuring compliance with international standards for safety and electromagnetic compatibility.

Image: CE and EMC Certification.
7. User Tips
- Software and Firmware Updates: Regularly check the official Hantek website for the latest software and firmware updates to ensure optimal performance and access to new features.
- Video Tutorials: Hantek provides video learning resources for up to 48 products. These can be invaluable for understanding specific functions and advanced operations. Visit the official website for these resources.
- Probe Selection: When purchasing, consider if you need more than one original probe. Some configurations come with one, while others might require additional purchases depending on your needs.
8. Warranty and Support
For detailed warranty information, technical support, software downloads, and additional user manuals, please visit the official Hantek website:
- Official Website: https://hantek.com/
- Product Information: https://hantek.com/products/detail/18191
- Tablet 1000 Software: https://hantek.com/Products/SoftwareDL?id=43621
- WaveEditor Software: https://hantek.com/Products/SoftwareDL?id=43646
- Firmware: https://hantek.com/Products/SoftwareDL?id=45827
- Data Manual: https://hantek.com/Products/SoftwareDL?id=43549
- Quick Guide: https://hantek.com/Products/SoftwareDL?id=43550
- SCPI Manual: https://hantek.com/Products/SoftwareDL?id=43551
- User Manual: https://hantek.com/Products/SoftwareDL?id=43552
For any issues not covered in this manual, please contact Hantek customer support through their official website.